{"id":4473,"date":"2025-03-27T14:35:19","date_gmt":"2025-03-27T07:35:19","guid":{"rendered":"https:\/\/www.barascientific.com\/product\/?p=4473"},"modified":"2025-07-16T14:12:19","modified_gmt":"2025-07-16T07:12:19","slug":"uv-2600i-plus-uv-2700i","status":"publish","type":"post","link":"https:\/\/www.barascientific.com\/product\/uv-2600i-plus-uv-2700i\/","title":{"rendered":"UV-2600i Plus\/UV-2700i Plus &#8212; UV-Vis Spectrophotometer"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Versatile, Expandable Mid-Range UV Spectrophotometers for Diverse Applications<\/h2>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"alignright\"><a href=\"https:\/\/www.shimadzu.com\/an\/products\/molecular-spectroscopy\/uv-vis-nir-spectroscopy\/uv-i-selection\/index.html\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" src=\"https:\/\/www.shimadzu.com\/an\/sites\/shimadzu.com.an\/files\/d7\/ckeditor\/an\/molecular_spectro\/uv\/uv2600i2700iplus\/UV-i_Selection_smallbanner.png\" alt=\"UV i-selection\"\/><\/a><\/figure><\/div>\n\n\n<p>The UV-2600i Plus is a single monochromator system with an expandable wavelength range up to 1400 nm using an optional integrating sphere, making it adaptable for various needs.<br>The UV-2700i Plus is a double monochromator system capable of 8-Abs measurements, ideal for low transmittance samples.<\/p>\n\n\n\n<p><br>Both models come equipped with the intuitive Shimadzu LabSolutions UV-Vis software, ensuring data integrity and ease of use. Additionally, these spectrophotometers can be scheduled to shut down or enter sleep mode to save power and lamp life, and can automatically wake up at a specified time, enhancing efficiency. Elevate your analysis with these versatile and efficient spectrophotometers.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"250\" src=\"https:\/\/www.barascientific.com\/product\/wp-content\/uploads\/2025\/03\/image-25-1024x250.png\" alt=\"\" class=\"wp-image-4481\" srcset=\"https:\/\/www.barascientific.com\/product\/wp-content\/uploads\/2025\/03\/image-25-1024x250.png 1024w, https:\/\/www.barascientific.com\/product\/wp-content\/uploads\/2025\/03\/image-25-300x73.png 300w, https:\/\/www.barascientific.com\/product\/wp-content\/uploads\/2025\/03\/image-25-768x187.png 768w, https:\/\/www.barascientific.com\/product\/wp-content\/uploads\/2025\/03\/image-25-696x170.png 696w, https:\/\/www.barascientific.com\/product\/wp-content\/uploads\/2025\/03\/image-25-1068x260.png 1068w, https:\/\/www.barascientific.com\/product\/wp-content\/uploads\/2025\/03\/image-25.png 1230w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Perfect for a Wide Variety of Applications<\/h2>\n\n\n\n<p>The functionality of the UV-2600i Plus \/2700i Plus can be freely expanded to suit the measurement objective. By accommodating a wealth of accessories, the system can address any user\u2019s applications and a variety of situations. Thanks to intuitive operations, anyone can easily obtain the data required.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/www.shimadzu.com\/an\/sites\/shimadzu.com.an\/files\/d7\/ckeditor\/an\/molecular_spectro\/uv\/uv2600i2700iplus\/ft1_1.png\" alt=\"Extensive Selection of Application Programs for a Wide Variety of Applications\"\/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Single monochromator UV-2600i Plus<\/h3>\n\n\n\n<p>A key feature of the UV-2600i Plus equipped with a single monochromator is its measurement wavelength range. By using the optional ISR-2600Plus Integrating Sphere attachment, the measurement wavelength range can be extended from 220 nm to 1400 nm, significantly expanding its applications.<\/p>\n\n\n\n<p><strong>Integrating Sphere Enables Measurements to 1400 nm<\/strong><\/p>\n\n\n\n<p>The UV-2600i Plus is equipped with Shimadzu&#8217;s proprietary LO-RAY-LIGH\u2122 grade diffraction grating, which achieves high efficiency and low stray light levels. By installing the ISR-2600Plus two-detector integrating sphere, the 300 nm to 1100 nm wavelength range of conventional models can be extended to 1400 nm. In addition, the UV-2600i achieves a significant noise reduction, and can accommodate measurements of solar cell anti-reflective films and polycrystalline silicon wafers.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"365\" height=\"228\" src=\"https:\/\/www.barascientific.com\/product\/wp-content\/uploads\/2025\/03\/image-22.png\" alt=\"\" class=\"wp-image-4474\" srcset=\"https:\/\/www.barascientific.com\/product\/wp-content\/uploads\/2025\/03\/image-22.png 365w, https:\/\/www.barascientific.com\/product\/wp-content\/uploads\/2025\/03\/image-22-300x187.png 300w\" sizes=\"auto, (max-width: 365px) 100vw, 365px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"421\" src=\"https:\/\/www.barascientific.com\/product\/wp-content\/uploads\/2025\/03\/image-23-1024x421.png\" alt=\"\" class=\"wp-image-4475\" srcset=\"https:\/\/www.barascientific.com\/product\/wp-content\/uploads\/2025\/03\/image-23-1024x421.png 1024w, https:\/\/www.barascientific.com\/product\/wp-content\/uploads\/2025\/03\/image-23-300x123.png 300w, https:\/\/www.barascientific.com\/product\/wp-content\/uploads\/2025\/03\/image-23-768x316.png 768w, https:\/\/www.barascientific.com\/product\/wp-content\/uploads\/2025\/03\/image-23-1020x420.png 1020w, https:\/\/www.barascientific.com\/product\/wp-content\/uploads\/2025\/03\/image-23-696x286.png 696w, https:\/\/www.barascientific.com\/product\/wp-content\/uploads\/2025\/03\/image-23.png 1052w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"454\" src=\"https:\/\/www.barascientific.com\/product\/wp-content\/uploads\/2025\/03\/image-24-1024x454.png\" alt=\"\" class=\"wp-image-4476\" srcset=\"https:\/\/www.barascientific.com\/product\/wp-content\/uploads\/2025\/03\/image-24-1024x454.png 1024w, https:\/\/www.barascientific.com\/product\/wp-content\/uploads\/2025\/03\/image-24-300x133.png 300w, https:\/\/www.barascientific.com\/product\/wp-content\/uploads\/2025\/03\/image-24-768x340.png 768w, https:\/\/www.barascientific.com\/product\/wp-content\/uploads\/2025\/03\/image-24-948x420.png 948w, https:\/\/www.barascientific.com\/product\/wp-content\/uploads\/2025\/03\/image-24-696x308.png 696w, https:\/\/www.barascientific.com\/product\/wp-content\/uploads\/2025\/03\/image-24.png 1052w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Measures Slight Differences in Absorbance<\/h2>\n\n\n\n<p>Equipped with a double monochromator that achieves ultra-low stray light levels, the UV-2700i Plus is optimal for measuring low transmittance samples, such as polarization films used for LCD panels. The UV-2700i Plus is capable of 8 Abs measurements, and can make accurate transmittance measurements to 1 part in 100 million, accommodating a variety of sample measurements.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Achieves Ultra-Low Stray Light, Enabling 8-Abs Measurements<\/h3>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"alignright\"><img decoding=\"async\" src=\"https:\/\/www.shimadzu.com\/an\/sites\/shimadzu.com.an\/files\/d7\/ckeditor\/an\/molecular_spectro\/uv\/uv2600i2700iplus\/ft2_4.png\" alt=\"Achieves Ultra-Low Stray Light, Enabling 8-Abs Measurements\"\/><\/figure><\/div>\n\n\n<p>In the case of a device equipped with a general double monochromator, the absorbance that can be covered is about 5 to 6, but the UV-2700i Plus offers a range to 8 Abs, with a transmittance value of 0.000001 % (1 part in 100 million). This system achieves high-level absorbance measurements with incomparable precision. In addition to measuring even high-concentration samples as is, eliminating the need to dilute samples, the system can be applied to evaluating the transmission characteristics of polarization films. Wavelengths in the 400 nm to 650 nm range can be measured to 8 Abs.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/www.shimadzu.com\/an\/sites\/shimadzu.com.an\/files\/d7\/ckeditor\/an\/molecular_spectro\/uv\/uv2600i2700iplus\/ft2_5.png\" alt=\"Achieves Ultra-Low Stray Light, Enabling 8-Abs Measurements\"\/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Sample Polarization Film Measurement<\/h3>\n\n\n\n<p>With the rotating film holder (image below), two film samples can be set on the same optical axis. In this example, the polarization film is rotated in the plane, and the transmittance is measured when the film transmits and blocks light.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><img decoding=\"async\" src=\"https:\/\/www.shimadzu.com\/an\/sites\/shimadzu.com.an\/files\/d7\/ckeditor\/an\/molecular_spectro\/uv\/uv2600i2700iplus\/ft2_6.png\" alt=\"Sample Polarization Film Measurement\"><\/li>\n\n\n\n<li><img decoding=\"async\" src=\"https:\/\/www.shimadzu.com\/an\/sites\/shimadzu.com.an\/files\/d7\/ckeditor\/an\/molecular_spectro\/uv\/uv2600i2700iplus\/ft2_7.png\" alt=\"Sample Polarization Film Measurement\"><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Enables Compliance with ER\/ES Regulations and Stronger Data Management<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Compatible with Validation from PC Software<\/h3>\n\n\n\n<p>Validation can be implemented with PC software using UV validation software. In addition to simplifying daily inspections, this makes instrument performance checks and records management easier, enabling more secure regulatory compliance.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<ul class=\"wp-block-list\">\n<li><img decoding=\"async\" src=\"https:\/\/www.shimadzu.com\/an\/sites\/shimadzu.com.an\/files\/d7\/ckeditor\/an\/molecular_spectro\/uv\/uv2600i2700iplus\/ft3_1.png\" alt=\"Compatible with Validation from PC Software\">\u2022 Inspection results can not only be printed but also saved to a file, so the results can be called up later for confirmation.<br>\u2022 The inspection parameters can also be saved to separate files for periodic and routine inspections and then called up for use.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<ul class=\"wp-block-list\">\n<li><img decoding=\"async\" src=\"https:\/\/www.shimadzu.com\/an\/sites\/shimadzu.com.an\/files\/d7\/ckeditor\/an\/molecular_spectro\/uv\/uv2600i2700iplus\/ft3_2.png\" alt=\"Compatible with Validation from PC Software\">\u2022 The user can select confirmation of instrument performance indicators as per JIS K 0115 General rules for molecular absorptiometric analysis, as well as the general test methods in the Japanese Pharmacopeia. (Order inspection jigs and reagents separately.)<br><br>Note: Optional validation software is required to support the US Pharmacopeia and European Pharmacopeia.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Support for FDA 21 CFR Part 11, PIC\/S GMP Guidelines and Other Regulations and Guidelines<\/h3>\n\n\n\n<p>&nbsp;Ensuring the integrity of data (database management), including the user management, user authority management, and data audit trails required for compliance with FDA 21 CFR Part 11, PIC\/S GMP guidelines, and other ER\/ES regulations is possible.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Option Software Assists with Regulation-Compliant Validation<\/h3>\n\n\n\n<p>UV validation software assists with performing the measurements and calculations required for validation. The software is included standard with UV-2600i\/2700i models. In addition to routine inspections, it can also be used to perform instrument validation that is compliant with Japanese, US, and European pharmacopoeias.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">What is Instrument Validation?<\/h3>\n\n\n\n<p>Instrument validation is an essential process for assessing and managing instrument health. What are the key elements of validation and how should they be performed? For more details, refer to the explanation page.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Assist Function<\/h2>\n\n\n\n<p>The instrument assists the user to ensure that measurements<br>are performed using&nbsp;the correct procedure.<sup>*1<\/sup><\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p><img decoding=\"async\" src=\"https:\/\/www.shimadzu.com\/an\/sites\/shimadzu.com.an\/files\/d7\/ckeditor\/an\/molecular_spectro\/uv\/uv1900iPlus\/assist_1.png\" alt=\"Verifies implementation of correction\">Checks whether or not baseline correction, auto zero correction or cell blank correction&nbsp;has been performed and informs the user if it has not been.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<ul class=\"wp-block-list\">\n<li><img decoding=\"async\" src=\"https:\/\/www.shimadzu.com\/an\/sites\/shimadzu.com.an\/files\/d7\/ckeditor\/an\/molecular_spectro\/uv\/uv1900iPlus\/assist_2.png\" alt=\"Confirms conditions of correction\"><br>Informs the user if the last correction performed is not appropriate for the planned measurement.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<ul class=\"wp-block-list\">\n<li><img decoding=\"async\" src=\"https:\/\/www.shimadzu.com\/an\/sites\/shimadzu.com.an\/files\/d7\/ckeditor\/an\/molecular_spectro\/uv\/uv1900iPlus\/assist_3.png\" alt=\"Implementation of measurements\">Informs the user if the UV-1900i Plus is not ready to begin measurement and&nbsp;when starting measurements<br>and 100 %T (0 Abs) corrections.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n\n\n<p class=\"has-small-font-size\">*1 This function can be enabled\/disabled.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Shutdown\/Wakeup Functions<\/h2>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"alignright\"><img decoding=\"async\" src=\"https:\/\/www.shimadzu.com\/an\/sites\/shimadzu.com.an\/files\/d7\/ckeditor\/an\/molecular_spectro\/uv\/uv2600i2700iplus\/ft3_3.png\" alt=\"Shutdown\/Wakeup Functions\"\/><\/figure><\/div>\n\n\n<p>The instrument can be shut down, and put into sleep mode. Putting the instrument into sleep mode limits power consumption and helps preserve the lamp. After a long period of measurements, the instrument and software can automatically be shut down. After shutdown, the instrument can also be set to wake up automatically at a specified time. With this function, analysis can start the instant the user arrives at the laboratory.<\/p>\n\n\n\n<p class=\"has-small-font-size\">SolidSpec, TMSPC, LabSolutions, the Analytical Intelligence logo, LO-RAY-LIGH and PPSQ are trademarks of Shimadzu Corporation or its affiliated companies in Japan and\/or other countries.<br>Excel, Microsoft and Azure are either registered trademarks or trademarks of Microsoft Corporation in the United States and\/or other countries.<br>Amazon Web Services and AWS are trademarks of Amazon.com, Inc. or its subsidiaries.<br>Google Cloud Platform and GCP are trademarks of Google LLC.<\/p>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"UV 2600\/2700 UV-Vis Spectrophotometers\" width=\"696\" height=\"392\" src=\"https:\/\/www.youtube.com\/embed\/5o0DZVgSVS8?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Versatile, Expandable Mid-Range UV Spectrophotometers for Diverse Applications The UV-2600i Plus is a single monochromator system with an expandable wavelength range up to 1400 nm using an optional integrating sphere, making it adaptable for various needs.The UV-2700i Plus is a double monochromator system capable of 8-Abs measurements, ideal for low transmittance samples. Both models come [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":4478,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[125,97],"tags":[],"class_list":{"0":"post-4473","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-new-product","8":"category-uv-vis-spectrophotometer"},"_links":{"self":[{"href":"https:\/\/www.barascientific.com\/product\/wp-json\/wp\/v2\/posts\/4473","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.barascientific.com\/product\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.barascientific.com\/product\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.barascientific.com\/product\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.barascientific.com\/product\/wp-json\/wp\/v2\/comments?post=4473"}],"version-history":[{"count":5,"href":"https:\/\/www.barascientific.com\/product\/wp-json\/wp\/v2\/posts\/4473\/revisions"}],"predecessor-version":[{"id":4926,"href":"https:\/\/www.barascientific.com\/product\/wp-json\/wp\/v2\/posts\/4473\/revisions\/4926"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.barascientific.com\/product\/wp-json\/wp\/v2\/media\/4478"}],"wp:attachment":[{"href":"https:\/\/www.barascientific.com\/product\/wp-json\/wp\/v2\/media?parent=4473"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.barascientific.com\/product\/wp-json\/wp\/v2\/categories?post=4473"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.barascientific.com\/product\/wp-json\/wp\/v2\/tags?post=4473"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}