<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	xmlns:media="http://search.yahoo.com/mrss/" >

<channel>
	<title>OES &#8211; Product</title>
	<atom:link href="https://www.barascientific.com/product/category/scientific-equipments/elemental-analzer/optical-emission-spectrometer/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.barascientific.com/product</link>
	<description>Solution of Success</description>
	<lastBuildDate>Fri, 11 Jul 2025 06:54:47 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8.3</generator>
	<item>
		<title>PDA-5000 — Optical Emission Spectrometer</title>
		<link>https://www.barascientific.com/product/pda-5000-optical-emission-spectrometer/</link>
					<comments>https://www.barascientific.com/product/pda-5000-optical-emission-spectrometer/#respond</comments>
		
		<dc:creator><![CDATA[Bara Scientific]]></dc:creator>
		<pubDate>Tue, 13 Jun 2023 08:14:12 +0000</pubDate>
				<category><![CDATA[OES]]></category>
		<guid isPermaLink="false">http://www.barascientific.com/product/?p=3110</guid>

					<description><![CDATA[Top Perfor mance of Analysis PDA-5000 integrates the essence and the latest analysis technology of Shimadzu spectrometer. It is a ground direct-reading spectrometer customized for casting and metal processing enterprises in the world, suitable for analysis from the lab to the front of furnace, even more severe environment. Relying on reliable digital excitation source design, [&#8230;]]]></description>
										<content:encoded><![CDATA[
<p><strong>Top Perfor mance of Analysis</strong></p>



<p>PDA-5000 integrates the essence and the latest analysis technology of Shimadzu spectrometer. It is a ground direct-reading spectrometer customized for casting and metal processing enterprises in the world, suitable for analysis from the lab to the front of furnace, even more severe environment. Relying on reliable digital excitation source design, this equipment can be integrated with unique factory calibration curve and humanized operation software, which can make accurate certification and stable analysis on demanded elements, while ensuring simple operation and convenient maintenance. It is the ideal selection for enterprises of metal manufacturing and processing.</p>



<p><strong>Main application fields and analysis materials</strong></p>



<p>It can be applied to fields of steel, casting, machines and auto &amp; auto parts, with the following conventional analysis:</p>



<figure class="wp-block-image size-large td-caption-align-https://www.barascientific.com/product/wp-content/uploads/2023/06/PDA-5000_image1.jpg"><img fetchpriority="high" decoding="async" width="555" height="394" src="http://www.barascientific.com/product/wp-content/uploads/2023/06/PDA-5000_image1.jpg" alt="" class="wp-image-3111" srcset="https://www.barascientific.com/product/wp-content/uploads/2023/06/PDA-5000_image1.jpg 555w, https://www.barascientific.com/product/wp-content/uploads/2023/06/PDA-5000_image1-300x213.jpg 300w, https://www.barascientific.com/product/wp-content/uploads/2023/06/PDA-5000_image1-100x70.jpg 100w" sizes="(max-width: 555px) 100vw, 555px" /></figure>



<p>Carbon structural steel: Crank, Gear, Piston and other auto parts Cast iron: Engines and pump valve and so on High-chromium iron: Wear-resistant material Stainless steel: Materials for making transmission equipment of food, drugs and petroleum Bearing steel: Roller for high-speed rail, aero-engine</p>



<p><strong>Brand new digital excitation source</strong></p>



<p>Brand new designed digital excitation source, non-auxiliary electrode and free maintenance and design; The excitation energy and excitation frequency are flexible and adjustable, which form to be the condition of various excitation source bars, and the measures for different metallic materials are complete.</p>



<figure class="wp-block-image size-large td-caption-align-https://www.barascientific.com/product/wp-content/uploads/2023/06/PDA-5000_image2.jpg"><img decoding="async" width="480" height="250" src="http://www.barascientific.com/product/wp-content/uploads/2023/06/PDA-5000_image2.jpg" alt="" class="wp-image-3112" srcset="https://www.barascientific.com/product/wp-content/uploads/2023/06/PDA-5000_image2.jpg 480w, https://www.barascientific.com/product/wp-content/uploads/2023/06/PDA-5000_image2-300x156.jpg 300w" sizes="(max-width: 480px) 100vw, 480px" /></figure>



<p>Unique design of spark stand</p>



<figure class="wp-block-image size-large td-caption-align-https://www.barascientific.com/product/wp-content/uploads/2023/06/PDA-5000_image3.jpg"><img decoding="async" width="484" height="195" src="http://www.barascientific.com/product/wp-content/uploads/2023/06/PDA-5000_image3.jpg" alt="" class="wp-image-3113" srcset="https://www.barascientific.com/product/wp-content/uploads/2023/06/PDA-5000_image3.jpg 484w, https://www.barascientific.com/product/wp-content/uploads/2023/06/PDA-5000_image3-300x121.jpg 300w" sizes="(max-width: 484px) 100vw, 484px" /></figure>



<p>The sliding enclosed excitation table design is adopted, reducing the influence of powder under severe environment before treatment in furnace; meanwhile the sample of any size can be measured accurately;<br>Large test board made of special stainless steel is used. The durability is enhanced while the operation is ensured convenient;<br>Measure various irregular samples by selecting analysis tools of wires and small samples.</p>



<p><strong>Standardized automatic judgement</strong></p>



<p>The stability of analysis is enhanced by combining the timing standardization and the standardization of automatic judgement according to the analysis results.</p>



<p><strong>Excellent extended function</strong></p>



<p>Unique factory calibration curve is integrated with the on-site correction curve to ensure the best analysis precision and accuracy of instruments;</p>



<figure class="wp-block-image size-large td-caption-align-https://www.barascientific.com/product/wp-content/uploads/2023/06/PDA-5000_image4.jpg"><img loading="lazy" decoding="async" width="241" height="293" src="http://www.barascientific.com/product/wp-content/uploads/2023/06/PDA-5000_image4.jpg" alt="" class="wp-image-3114"/></figure>



<p>Passages can be added on site according to client requirements, while various extended applications can be performed, so as to satisfy the demand of future analysis.</p>



<p> <strong>
<!--change the width and height value as you want.--> 
<!-- Do change "index.htm" to your real html name of the flippingbook--> 
<iframe  style="width:100%;height:450px"  src="https://www.barascientific.com/product/wp-content/uploads/flipbook/304/book.html"  seamless="seamless" scrolling="no" frameborder="0" allowtransparency="true" allowfullscreen mozallowfullscreen  webkitallowfullscreen ></iframe>
</strong> </p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.barascientific.com/product/pda-5000-optical-emission-spectrometer/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>PDA-7000 &#8212; Optical Emission Spectrometer</title>
		<link>https://www.barascientific.com/product/pda-7000-optical-emission-spectrometer/</link>
					<comments>https://www.barascientific.com/product/pda-7000-optical-emission-spectrometer/#respond</comments>
		
		<dc:creator><![CDATA[Bara Scientific]]></dc:creator>
		<pubDate>Thu, 23 Aug 2018 08:39:46 +0000</pubDate>
				<category><![CDATA[OES]]></category>
		<category><![CDATA[PDA-7000]]></category>
		<guid isPermaLink="false">http://www.barascientific.com/product/?p=1234</guid>

					<description><![CDATA[Emission spectrometry provides rapid and accurate simultaneous determination of many elements in metals. This technique has been adopted as standard method for metal analysis. The Shimadzu PDA-7000 is high performance optical emission spectrometers, utilizing the PDA method as standard, which enhances the accuracy and reliability of analysis. The PDA method, combined with excellent hardware quality, [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>Emission spectrometry provides rapid and accurate simultaneous determination of many elements in metals. This technique has been adopted as standard method for metal analysis. The Shimadzu PDA-7000 is high performance optical emission spectrometers, utilizing the PDA method as standard, which enhances the accuracy and reliability of analysis. The PDA method, combined with excellent hardware quality, make the PDA-7000 suitable for any application in metal analysis. They enhance analysis productivity in quality control and process control in the ferrous and non-ferrous metal industries.</p>
<section class="l-fullWidth--PCContents">
<h2>Vacuum Monochromator</h2>
<div class="u-ckeditor">
<div>
<section class="article-set">
<section class="image-set">
<figure class="image-set-image image-set-image-pull-right"><img loading="lazy" decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/elemental/oes/pda7000/qn50420000005mao-img/pic01.png" alt="" width="300" height="308"></figure>
<p>The monochromator must be held in a vacuum or in a gas-replacement atmosphere to avoid effects due to the absorption of spectral lines such as C, P, S, B, and N by atmospheric oxygen.<br>
Shimadzu adopts a vacuum monochromator that is resistant to the effects of temperature fluctuations. It is installed in a temperature-controlled monochromator chamber to achieve extremely stable measurements.</p>
</section>
</section>
</div>
</div>
</section>
<section class="l-fullWidth--PCContents"><a id="anchor_1" class="u-anchor" name="anchor_1"></a><p></p>
<h2>New Spark Stand Enhances Stability</h2>
<div class="u-ckeditor">
<div>
<section class="article-set">
<section class="image-set">
<figure class="image-set-image image-set-image-pull-right">
<div class="image-with-caption">
<div class="image-with-caption-inner">
<div class="image-with-caption-image"><img loading="lazy" decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/elemental/oes/pda7000/qn50420000005mao-img/pic02.png" alt="" width="350" height="256"></div>
<p class="image-with-caption-caption-text">Spark Stand</p>
</div>
</div>
</figure>
<p>The structure and materials of the conventional spark stand have been upgraded to considerably enhance analysis accuracy for high-concentration elements (stainless steel and aluminum alloy). It accepts large sample plates, offers greater ease of handling, and enhances durability.<br>
Further, selecting the optional stand water-cooling kit (see page 12) restricts the spark stand temperature rise due to electrical discharge during continuous analysis, thereby enhancing the stability of the measured values.</p>
<h2>User-friendly Software</h2>
<div class="u-ckeditor">
<div>
<section class="article-set">
<p class="paragraph">The software was designed for process analysis, with due consideration of the situation at sites where metals analysis is conducted. After the instrument is started, only one action is required to enable measurement and allow simple process analysis.<br>
Simply enter the required information in sequence to easily create the analysis information.</p>
</section>
</div>
<div>
<section class="article-set">
<h3 class="heading-normal">Superbly Functional Software Supports Your Operation</h3>
<div class="parent-block parent-block-col-2 margin-bottom-20">
<div class="unit">
<div class="image-with-caption">
<div class="image-with-caption-inner">
<div class="image-with-caption-image"><img loading="lazy" decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/elemental/oes/pda7000/qn50420000005mao-img/pic03.png" alt="" width="350" height="279"></div>
<p class="image-with-caption-caption-text">Analysis Information Screen</p>
</div>
</div>
</div>
<div class="unit">
<div class="image-with-caption">
<div class="image-with-caption-inner">
<div class="image-with-caption-image"><img loading="lazy" decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/elemental/oes/pda7000/qn50420000005mao-img/pic04.png" alt="" width="350" height="265"></div>
<p class="image-with-caption-caption-text">Calibration Curve Screen</p>
</div>
</div>
</div>
</div>
<div class="parent-block parent-block-col-2 margin-bottom-20">
<div class="unit">
<div class="image-with-caption">
<div class="image-with-caption-inner">
<div class="image-with-caption-image"><img loading="lazy" decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/elemental/oes/pda7000/qn50420000005mao-img/pic05.png" alt="" width="350" height="279"></div>
<p class="image-with-caption-caption-text">Control Chart</p>
</div>
</div>
</div>
<div class="unit">
<div class="image-with-caption">
<div class="image-with-caption-inner">
<div class="image-with-caption-image"><img loading="lazy" decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/elemental/oes/pda7000/qn50420000005mao-img/pic06.png" alt="" width="350" height="274"></div>
<p class="image-with-caption-caption-text">Content Analysis Screen</p>
</div>
</div>
</div>
</div>
</section>
</div>
<div>
<section class="article-set">
<div class="parent-block parent-block-col-2 margin-bottom-20">
<div class="unit">
<div class="image-with-caption">
<div class="image-with-caption-inner">
<p class="image-with-caption-caption-text">Analysis data can be transferred to host computers and printer.</p>
<div class="image-with-caption-image"><img loading="lazy" decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/elemental/oes/pda7000/qn50420000005mao-img/pic07.png" alt="" width="486" height="234"></div>
</div>
</div>
</div>
<div class="unit">
<div class="image-with-caption">
<div class="image-with-caption-inner">
<p class="image-with-caption-caption-text">Analysis Information and results can be used in commercial database/spreadsheet software.</p>
<div class="image-with-caption-image"><img loading="lazy" decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/elemental/oes/pda7000/qn50420000005mao-img/pic08.png" alt="" width="383" height="219"></div>
</div>
</div>
</div>
</div>
</section>
</div>
<div>
<section class="article-set">
<h2 class="heading-02">High-sensitivity Analysis of Nitrogen in Steel</h2>
<p class="paragraph">Due to the significant effects of nitrogen on the mechanical properties of steel, the rapid measurement of nitrogen during the manufacturing process is highly desirable.<br>
The PDA-7000 has recently been developed to replace gas analyzers for in-furnace analysis. It achieves a lower detectable limit of 5ppm. This instrument reduces sampling operations and shortens analysis times. Additionally, it eliminates sample defects and enhances yields through its ability to control nitrogen in cast iron.</p>
</section>
</div>
<div>
<section class="article-set">
<h2 class="heading-02">Sensitive Analysis of Trace Elements in Steel</h2>
<p class="paragraph">The establishment of manufacturing technologies for high-purity iron demands process control at lower trace levels of elements, including C, P, and S.<br>
The PDA-7000 meets these needs by permitting quick and easy ppm-level analysis by time-resolution PDA photometry.</p>
</section>
</div>
<div>
<section class="article-set">
<h2 class="heading-02">Elimination of Contamination Effects</h2>
<p class="paragraph">Replaceable units in the new spark stand eliminate to the maximum degree effects from high-content sample analysis during trace-element analysis.<br>
This effectively eliminates effects from the analysis of aluminum alloys when high-purity aluminum is analyzed, for example.</p>
</section>
</div>
<div>
<section class="article-set">
<h2 class="heading-02">Electrode Cleaning Extends Electrode Life approx. 10 Times</h2>
<p class="paragraph">Electrode life is increased by approximately ten times by adopting brushing for electrode regeneration in addition to conventional reversed discharge. Naturally, the convenient reversed discharge is also provided as standard.<br>
To enhance long-term stability, the optional automatic electrode-cleaning unit (page 12) can be selected to keep the counter electrode clean by automatically brushing away adhering sample deposits. The attached automatic sample retainer mechanism allows everyone to set samples under identical conditions.</p>
</section>
</div>
<div>
<section class="article-set">
<h2 class="heading-02">New Chassis Case Design offers Superb Environmental Resistance</h2>
<p class="paragraph">The newly designed chassis case enhances environmental resistance.<br>
The monochromator is made of materials resistant to the effects of temperature fluctuations and is installed in a constant-temperature chamber.<br>
The popular compact design is retained. The chassis case can be mounted against the wall to save space. The functional design allows maintenance access from the front.<br>
The chassis case design offers greater freedom in analysis laboratory layout.</p>
</section>
</div>
<div>
<section class="article-set">
<h2 class="heading-02">Select Optimal Discharge Conditions to Suit Analysis Range and Elements</h2>
<p class="paragraph">Several separate discharge types are available for each analyzed element: high-energy discharge, spark discharge for excellent reproducibility, and arc-like spark discharge for high sensitivity. A combination of these can also be selected to set the optimal discharge conditions.<br>
Used with time-resolution photometry, these settings achieve high analysis accuracy.<br>
The addition of the optional small-sample analysis kit (page 12) permits measurements on 0.01mm-thick samples and small-diameter samples.</p>
</section>
</div>
<div>
<section class="article-set">
<h2 class="heading-02">Extremely Simple Operation</h2>
<p class="paragraph">Simply mount a sample in the spark stand, enter the sample number, and press the start button to display the analysis results on the screen in just over ten seconds. (The actual analysis time depends on the analysis conditions.)<br>
The analysis data can be easily converted for flexible processing by commercial software.</p>
</section>
</div>
<div>
<section class="article-set">
<h2 class="heading-02">Energy-Saving Design to Reduce Running Cost</h2>
<p class="paragraph">While the instrument is not in analysis mode, argon gas flow is reduced to one-tenth compared with conventional model.<br>
Energy-saving design contributes lower running cost.</p>
</section>
</div>
</div>
</section>
</section>
</div>
</div>
</section>


<p> <strong>
<!--change the width and height value as you want.--> 
<!-- Do change "index.htm" to your real html name of the flippingbook--> 
<iframe  style="width:100%;height:450px"  src="https://www.barascientific.com/product/wp-content/uploads/flipbook/305/book.html"  seamless="seamless" scrolling="no" frameborder="0" allowtransparency="true" allowfullscreen mozallowfullscreen  webkitallowfullscreen ></iframe>
</strong> </p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.barascientific.com/product/pda-7000-optical-emission-spectrometer/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>PDA-8000 &#8212; Optical Emission Spectrometer</title>
		<link>https://www.barascientific.com/product/pda-8000-optical-emission-spectrometer/</link>
					<comments>https://www.barascientific.com/product/pda-8000-optical-emission-spectrometer/#respond</comments>
		
		<dc:creator><![CDATA[Bara Scientific]]></dc:creator>
		<pubDate>Thu, 23 Aug 2018 08:34:41 +0000</pubDate>
				<category><![CDATA[OES]]></category>
		<category><![CDATA[PDA-8000]]></category>
		<guid isPermaLink="false">http://www.barascientific.com/product/?p=1223</guid>

					<description><![CDATA[This instrument is capable of high sensitivity quantitative analysis of iron and steel, copper, aluminum alloys and other solid metals, as well as impurities and other elements, thanks to a high resolution monochromator and discharge energy stabilized excitation unit. Excellent operability is achieved with software that enhances instrument monitoring and maintenance support functionality. In addition, [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>This instrument is capable of high sensitivity quantitative analysis of iron and steel, copper, aluminum alloys and other solid metals, as well as impurities and other elements, thanks to a high resolution monochromator and discharge energy stabilized excitation unit. Excellent operability is achieved with software that enhances instrument monitoring and maintenance support functionality. In addition, this is an energy saving model that significantly reduces energy consumption.</p>
<section class="l-fullWidth--PCContents">
<h2>New monochromator design for greater stability</h2>
<div class="u-ckeditor">
<div>
<section class="article-set">
<h3 class="heading-normal">More Precise Analysis Achieved with a High Resolution Spectrometer</h3>
<section class="image-set">
<figure class="image-set-image image-set-image-pull-right"><img loading="lazy" decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/elemental/oes/pda8000/qn50420000005m2g-img/qn5042000000c7fs.jpg" alt="" width="170" height="119"></figure>
<p>Use of a diffraction grating with a wavelength range suitable for ferrous or non-ferrous applications in Paschen-Runge mounting of 1000 mm focal length offers high-resolution measurements over a wide wavelength range. More precise analysis becomes possible by reducing the effect of spectral interference.</p>
</section>
</section>
<div class="article-set">
<h3 class="heading-normal">Stable and Proven Vacuum Monochromator</h3>
<p>Phosphorus and Sulfur, important elements for the analysis of materials, have spectral lines in the vacuum-ultraviolet wavelength range lower than 190 nm.<br>
In this wavelength range, oxygen in the air absorbs light, so the removal of oxygen is required. The PDA-8000 uses a proven vacuum monochromator to provide stable spectroscopic analysis.</p>
</div>
<div class="article-set">
<h3 class="heading-normal">Light Receptor Condensing System</h3>
<section class="image-set">
<figure class="image-set-image image-set-image-pull-right"><img loading="lazy" decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/elemental/oes/pda8000/qn50420000005m4i-img/qn5042000000c7hz.jpg" alt="" width="256" height="150"></figure>
<p>Light passed through the exit slit is focused by a toroidal mirror on the photosensitive surface of a photomultiplier tube. This optical design enables stable measurement.</p>
</section>
</div>
<div class="article-set">
<h3 class="heading-normal">High Responsiveness to Changes in the Environment</h3>
<p>The spectrometer is made from materials that change little with temperature. In addition, by being located in a thermostatic chamber with enhanced thermal insulation performance, changes in the ambient temperature do not affect the instrument, permitting more precise analysis. (Ambient temperature 15 to 30 °C, ±5°C/hour max.)</p>
</div>
</div>
</div>
</section>
<section class="l-fullWidth--PCContents"><a id="anchor_1" class="u-anchor" name="anchor_1"></a><p></p>
<h2>A Novel Excitation Unit</h2>
<div class="u-ckeditor">
<div class="article-set">
<h3 class="heading-normal">Constant Monitoring of the Discharge Status</h3>
<section class="image-set">
<figure class="image-set-image image-set-image-pull-right"><img loading="lazy" decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/elemental/oes/pda8000/qn50420000005m6k-img/qn50420000005m7j.jpg" alt="Constant Monitoring of the Discharge Status" width="200" height="205"></figure>
<p>A Real-time Energy Monitoring* function monitors the discharge energy consumed between the counter electrode and the sample. The discharge energy is accurately set and controlled, and discharge defects due to the surface condition of the sample can be instantly detected from the discharge energy. The accuracy is improved by eliminating samples with defects from the measurement.<br>
*Patent pending</p>
</section>
</div>
<div class="article-set">
<h3 class="heading-normal">Supporting Diverse Metal Materials</h3>
<p>Many metal materials can be analyzed over a wide range of optimal discharge conditions, such as high-energy discharge for metals like steel with a high melting point, or low-energy discharge for metals like lead and zinc alloys with a low melting point, through the use of a newly-developed discharge energy stabilizing excitation unit.</p>
</div>
<div class="article-set">
<h3 class="heading-normal">Ultra Trace Analysis of High Purity Materials</h3>
<p>Current Regulative Spark* (CRS), capable of stabilizing the current for every pulse, improves analysis sensitivity of trace amounts.<br>
*Patent pending</p>
</div>
<div class="article-set">
<section class="image-set">
<figure class="image-set-image image-set-image-pull-left"><img loading="lazy" decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/elemental/oes/pda8000/qn50420000005m6k-img/qn5042000000c7j1.jpg" alt="Ultra Trace Analysis of High Purity Materials" width="510" height="198"></figure>
</section>
</div>
<div class="article-set">
<h3 class="heading-normal">Energy Efficient Design</h3>
<section class="image-set">
<figure class="image-set-image image-set-image-pull-right"><img loading="lazy" decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/elemental/oes/pda8000/qn50420000005m6k-img/qn5042000000c7jb.jpg" alt="" width="95" height="103"></figure>
<p>This energy-efficient spectrometer has a power consumption of 510 W (43 % reduction from our previous Optical Emission Spectrometer).*1 The argon gas consumption has also been reduced by about 45 % as compared to our previous model.*2<br>
*1 For analyzing 15 samples/hour<br>
*2 The consumption for analyzing 150 samples/8 hours in 1 day</p>
</section>
</div>
<div class="article-set">
<div class="text-center"><img loading="lazy" decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/elemental/oes/pda8000/qn50420000005m6k-img/qn5042000000c7jl.jpg" alt="Energy Efficient Design" width="501" height="111"></div>
</div>
</div>
</section>
<section class="l-fullWidth--PCContents"><a id="anchor_2" class="u-anchor" name="anchor_2"></a><p></p>
<h2>Intuitive Software PDA-R</h2>
<div class="u-ckeditor">
<div class="article-set">
<section class="image-set">
<h3 class="heading-normal">Fusion of Hardware and Software</h3>
<p>Integrating software with the hardware enables reliable instrument management, from control and diagnosis to maintenance.</p>
</section>
</div>
<div class="article-set">
<div class="text-center">
<div class="image-with-caption">
<div class="image-with-caption-inner">
<div class="image-with-caption-image"><img loading="lazy" decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/elemental/oes/pda8000/qn50420000005m8m-img/qn5042000000c7k6.jpg" alt="" width="513" height="467"></div>
<p class="image-with-caption-caption-text">Fusion of Hardware and Software</p>
</div>
</div>
</div>
</div>
<div class="article-set">
<h3 class="heading-normal">The Pursuit of Greater Ease-of-Use, Based on Reliability</h3>
<p>A sophisticated, yet operator-friendly design utilizing vast emission spectrometry experience has been produced.</p>
<p>Plots can be set for each sample, which enables more intuitive and easy-to-understand operation.</p>
</div>
<div class="article-set">
<div class="text-center"><img loading="lazy" decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/elemental/oes/pda8000/qn50420000005m8m-img/qn5042000000c7ko.jpg" alt="" width="520" height="479"></div>
</div>
</div>
</section>


<p> <strong>
<!--change the width and height value as you want.--> 
<!-- Do change "index.htm" to your real html name of the flippingbook--> 
<iframe  style="width:100%;height:450px"  src="https://www.barascientific.com/product/wp-content/uploads/flipbook/306/book.html"  seamless="seamless" scrolling="no" frameborder="0" allowtransparency="true" allowfullscreen mozallowfullscreen  webkitallowfullscreen ></iframe>
</strong> </p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.barascientific.com/product/pda-8000-optical-emission-spectrometer/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		