<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	xmlns:media="http://search.yahoo.com/mrss/" >

<channel>
	<title>Spectrophotometric &#8211; Product</title>
	<atom:link href="https://www.barascientific.com/product/category/analytical-instruments/spectrophotometric/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.barascientific.com/product</link>
	<description>Solution of Success</description>
	<lastBuildDate>Mon, 17 Nov 2025 06:57:59 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8.3</generator>
	<item>
		<title>UV-2600i Plus/UV-2700i Plus &#8212; UV-Vis Spectrophotometer</title>
		<link>https://www.barascientific.com/product/uv-2600i-plus-uv-2700i/</link>
					<comments>https://www.barascientific.com/product/uv-2600i-plus-uv-2700i/#comments</comments>
		
		<dc:creator><![CDATA[Bara Scientific]]></dc:creator>
		<pubDate>Thu, 27 Mar 2025 07:35:19 +0000</pubDate>
				<category><![CDATA[New Product]]></category>
		<category><![CDATA[UV-VIS]]></category>
		<guid isPermaLink="false">https://www.barascientific.com/product/?p=4473</guid>

					<description><![CDATA[Versatile, Expandable Mid-Range UV Spectrophotometers for Diverse Applications The UV-2600i Plus is a single monochromator system with an expandable wavelength range up to 1400 nm using an optional integrating sphere, making it adaptable for various needs.The UV-2700i Plus is a double monochromator system capable of 8-Abs measurements, ideal for low transmittance samples. Both models come [&#8230;]]]></description>
										<content:encoded><![CDATA[
<h2 class="wp-block-heading">Versatile, Expandable Mid-Range UV Spectrophotometers for Diverse Applications</h2>


<div class="wp-block-image">
<figure class="alignright"><a href="https://www.shimadzu.com/an/products/molecular-spectroscopy/uv-vis-nir-spectroscopy/uv-i-selection/index.html" target="_blank" rel="noopener"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/molecular_spectro/uv/uv2600i2700iplus/UV-i_Selection_smallbanner.png" alt="UV i-selection"/></a></figure></div>


<p>The UV-2600i Plus is a single monochromator system with an expandable wavelength range up to 1400 nm using an optional integrating sphere, making it adaptable for various needs.<br>The UV-2700i Plus is a double monochromator system capable of 8-Abs measurements, ideal for low transmittance samples.</p>



<p><br>Both models come equipped with the intuitive Shimadzu LabSolutions UV-Vis software, ensuring data integrity and ease of use. Additionally, these spectrophotometers can be scheduled to shut down or enter sleep mode to save power and lamp life, and can automatically wake up at a specified time, enhancing efficiency. Elevate your analysis with these versatile and efficient spectrophotometers.</p>



<figure class="wp-block-image size-large"><img fetchpriority="high" decoding="async" width="1024" height="250" src="https://www.barascientific.com/product/wp-content/uploads/2025/03/image-25-1024x250.png" alt="" class="wp-image-4481" srcset="https://www.barascientific.com/product/wp-content/uploads/2025/03/image-25-1024x250.png 1024w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-25-300x73.png 300w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-25-768x187.png 768w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-25-696x170.png 696w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-25-1068x260.png 1068w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-25.png 1230w" sizes="(max-width: 1024px) 100vw, 1024px" /></figure>



<h2 class="wp-block-heading">Perfect for a Wide Variety of Applications</h2>



<p>The functionality of the UV-2600i Plus /2700i Plus can be freely expanded to suit the measurement objective. By accommodating a wealth of accessories, the system can address any user’s applications and a variety of situations. Thanks to intuitive operations, anyone can easily obtain the data required.</p>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/molecular_spectro/uv/uv2600i2700iplus/ft1_1.png" alt="Extensive Selection of Application Programs for a Wide Variety of Applications"/></figure>



<h3 class="wp-block-heading">Single monochromator UV-2600i Plus</h3>



<p>A key feature of the UV-2600i Plus equipped with a single monochromator is its measurement wavelength range. By using the optional ISR-2600Plus Integrating Sphere attachment, the measurement wavelength range can be extended from 220 nm to 1400 nm, significantly expanding its applications.</p>



<p><strong>Integrating Sphere Enables Measurements to 1400 nm</strong></p>



<p>The UV-2600i Plus is equipped with Shimadzu&#8217;s proprietary LO-RAY-LIGH<img src="https://s.w.org/images/core/emoji/16.0.1/72x72/2122.png" alt="™" class="wp-smiley" style="height: 1em; max-height: 1em;" /> grade diffraction grating, which achieves high efficiency and low stray light levels. By installing the ISR-2600Plus two-detector integrating sphere, the 300 nm to 1100 nm wavelength range of conventional models can be extended to 1400 nm. In addition, the UV-2600i achieves a significant noise reduction, and can accommodate measurements of solar cell anti-reflective films and polycrystalline silicon wafers.</p>



<figure class="wp-block-image size-full"><img decoding="async" width="365" height="228" src="https://www.barascientific.com/product/wp-content/uploads/2025/03/image-22.png" alt="" class="wp-image-4474" srcset="https://www.barascientific.com/product/wp-content/uploads/2025/03/image-22.png 365w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-22-300x187.png 300w" sizes="(max-width: 365px) 100vw, 365px" /></figure>



<figure class="wp-block-image size-large"><img decoding="async" width="1024" height="421" src="https://www.barascientific.com/product/wp-content/uploads/2025/03/image-23-1024x421.png" alt="" class="wp-image-4475" srcset="https://www.barascientific.com/product/wp-content/uploads/2025/03/image-23-1024x421.png 1024w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-23-300x123.png 300w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-23-768x316.png 768w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-23-1020x420.png 1020w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-23-696x286.png 696w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-23.png 1052w" sizes="(max-width: 1024px) 100vw, 1024px" /></figure>



<figure class="wp-block-image size-large"><img loading="lazy" decoding="async" width="1024" height="454" src="https://www.barascientific.com/product/wp-content/uploads/2025/03/image-24-1024x454.png" alt="" class="wp-image-4476" srcset="https://www.barascientific.com/product/wp-content/uploads/2025/03/image-24-1024x454.png 1024w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-24-300x133.png 300w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-24-768x340.png 768w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-24-948x420.png 948w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-24-696x308.png 696w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-24.png 1052w" sizes="auto, (max-width: 1024px) 100vw, 1024px" /></figure>



<h2 class="wp-block-heading">Measures Slight Differences in Absorbance</h2>



<p>Equipped with a double monochromator that achieves ultra-low stray light levels, the UV-2700i Plus is optimal for measuring low transmittance samples, such as polarization films used for LCD panels. The UV-2700i Plus is capable of 8 Abs measurements, and can make accurate transmittance measurements to 1 part in 100 million, accommodating a variety of sample measurements.</p>



<h3 class="wp-block-heading">Achieves Ultra-Low Stray Light, Enabling 8-Abs Measurements</h3>


<div class="wp-block-image">
<figure class="alignright"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/molecular_spectro/uv/uv2600i2700iplus/ft2_4.png" alt="Achieves Ultra-Low Stray Light, Enabling 8-Abs Measurements"/></figure></div>


<p>In the case of a device equipped with a general double monochromator, the absorbance that can be covered is about 5 to 6, but the UV-2700i Plus offers a range to 8 Abs, with a transmittance value of 0.000001 % (1 part in 100 million). This system achieves high-level absorbance measurements with incomparable precision. In addition to measuring even high-concentration samples as is, eliminating the need to dilute samples, the system can be applied to evaluating the transmission characteristics of polarization films. Wavelengths in the 400 nm to 650 nm range can be measured to 8 Abs.</p>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/molecular_spectro/uv/uv2600i2700iplus/ft2_5.png" alt="Achieves Ultra-Low Stray Light, Enabling 8-Abs Measurements"/></figure>



<h3 class="wp-block-heading">Sample Polarization Film Measurement</h3>



<p>With the rotating film holder (image below), two film samples can be set on the same optical axis. In this example, the polarization film is rotated in the plane, and the transmittance is measured when the film transmits and blocks light.</p>



<ul class="wp-block-list">
<li><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/molecular_spectro/uv/uv2600i2700iplus/ft2_6.png" alt="Sample Polarization Film Measurement"></li>



<li><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/molecular_spectro/uv/uv2600i2700iplus/ft2_7.png" alt="Sample Polarization Film Measurement"></li>
</ul>



<h2 class="wp-block-heading">Enables Compliance with ER/ES Regulations and Stronger Data Management</h2>



<h3 class="wp-block-heading">Compatible with Validation from PC Software</h3>



<p>Validation can be implemented with PC software using UV validation software. In addition to simplifying daily inspections, this makes instrument performance checks and records management easier, enabling more secure regulatory compliance.</p>



<div class="wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex">
<div class="wp-block-column is-layout-flow wp-block-column-is-layout-flow">
<ul class="wp-block-list">
<li><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/molecular_spectro/uv/uv2600i2700iplus/ft3_1.png" alt="Compatible with Validation from PC Software">• Inspection results can not only be printed but also saved to a file, so the results can be called up later for confirmation.<br>• The inspection parameters can also be saved to separate files for periodic and routine inspections and then called up for use.</li>
</ul>
</div>



<div class="wp-block-column is-layout-flow wp-block-column-is-layout-flow">
<ul class="wp-block-list">
<li><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/molecular_spectro/uv/uv2600i2700iplus/ft3_2.png" alt="Compatible with Validation from PC Software">• The user can select confirmation of instrument performance indicators as per JIS K 0115 General rules for molecular absorptiometric analysis, as well as the general test methods in the Japanese Pharmacopeia. (Order inspection jigs and reagents separately.)<br><br>Note: Optional validation software is required to support the US Pharmacopeia and European Pharmacopeia.</li>
</ul>
</div>
</div>



<h3 class="wp-block-heading">Support for FDA 21 CFR Part 11, PIC/S GMP Guidelines and Other Regulations and Guidelines</h3>



<p>&nbsp;Ensuring the integrity of data (database management), including the user management, user authority management, and data audit trails required for compliance with FDA 21 CFR Part 11, PIC/S GMP guidelines, and other ER/ES regulations is possible.</p>



<h3 class="wp-block-heading">Option Software Assists with Regulation-Compliant Validation</h3>



<p>UV validation software assists with performing the measurements and calculations required for validation. The software is included standard with UV-2600i/2700i models. In addition to routine inspections, it can also be used to perform instrument validation that is compliant with Japanese, US, and European pharmacopoeias.</p>



<h3 class="wp-block-heading">What is Instrument Validation?</h3>



<p>Instrument validation is an essential process for assessing and managing instrument health. What are the key elements of validation and how should they be performed? For more details, refer to the explanation page.</p>



<h2 class="wp-block-heading">Assist Function</h2>



<p>The instrument assists the user to ensure that measurements<br>are performed using&nbsp;the correct procedure.<sup>*1</sup></p>



<div class="wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex">
<div class="wp-block-column is-layout-flow wp-block-column-is-layout-flow">
<p><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/molecular_spectro/uv/uv1900iPlus/assist_1.png" alt="Verifies implementation of correction">Checks whether or not baseline correction, auto zero correction or cell blank correction&nbsp;has been performed and informs the user if it has not been.</p>
</div>



<div class="wp-block-column is-layout-flow wp-block-column-is-layout-flow">
<ul class="wp-block-list">
<li><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/molecular_spectro/uv/uv1900iPlus/assist_2.png" alt="Confirms conditions of correction"><br>Informs the user if the last correction performed is not appropriate for the planned measurement.</li>
</ul>
</div>



<div class="wp-block-column is-layout-flow wp-block-column-is-layout-flow">
<ul class="wp-block-list">
<li><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/molecular_spectro/uv/uv1900iPlus/assist_3.png" alt="Implementation of measurements">Informs the user if the UV-1900i Plus is not ready to begin measurement and&nbsp;when starting measurements<br>and 100 %T (0 Abs) corrections.</li>
</ul>
</div>
</div>



<p class="has-small-font-size">*1 This function can be enabled/disabled.</p>



<h2 class="wp-block-heading">Shutdown/Wakeup Functions</h2>


<div class="wp-block-image">
<figure class="alignright"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/molecular_spectro/uv/uv2600i2700iplus/ft3_3.png" alt="Shutdown/Wakeup Functions"/></figure></div>


<p>The instrument can be shut down, and put into sleep mode. Putting the instrument into sleep mode limits power consumption and helps preserve the lamp. After a long period of measurements, the instrument and software can automatically be shut down. After shutdown, the instrument can also be set to wake up automatically at a specified time. With this function, analysis can start the instant the user arrives at the laboratory.</p>



<p class="has-small-font-size">SolidSpec, TMSPC, LabSolutions, the Analytical Intelligence logo, LO-RAY-LIGH and PPSQ are trademarks of Shimadzu Corporation or its affiliated companies in Japan and/or other countries.<br>Excel, Microsoft and Azure are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries.<br>Amazon Web Services and AWS are trademarks of Amazon.com, Inc. or its subsidiaries.<br>Google Cloud Platform and GCP are trademarks of Google LLC.</p>



<figure class="wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio"><div class="wp-block-embed__wrapper">
<iframe loading="lazy" title="UV 2600/2700 UV-Vis Spectrophotometers" width="696" height="392" src="https://www.youtube.com/embed/5o0DZVgSVS8?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe>
</div></figure>
]]></content:encoded>
					
					<wfw:commentRss>https://www.barascientific.com/product/uv-2600i-plus-uv-2700i/feed/</wfw:commentRss>
			<slash:comments>1</slash:comments>
		
		
		<media:content url="https://www.youtube.com/embed/5o0DZVgSVS8" medium="video" width="640" height="360">
			<media:player url="https://www.youtube.com/embed/5o0DZVgSVS8" />
			<media:title type="plain">UV 2600/2700 UV-Vis Spectrophotometers</media:title>
			<media:description type="html"><![CDATA[https://www.ssi.shimadzu.com/products/uv-vis-spectrophotometers/uv-2600i-uv-2700i.htmlThe UV-2600i and UV-2700i double-beam spectrophotometers are true resea...]]></media:description>
			<media:thumbnail url="https://www.barascientific.com/product/wp-content/uploads/2025/03/UV-2600i-Plus-1.jpg" />
			<media:rating scheme="urn:simple">nonadult</media:rating>
		</media:content>
	</item>
		<item>
		<title>UV-1900i Plus &#8212; UV-Vis Spectrophotometer</title>
		<link>https://www.barascientific.com/product/uv-1900i-plus-uv-vis-spectrophotometer/</link>
					<comments>https://www.barascientific.com/product/uv-1900i-plus-uv-vis-spectrophotometer/#comments</comments>
		
		<dc:creator><![CDATA[Bara Scientific]]></dc:creator>
		<pubDate>Thu, 27 Mar 2025 07:07:54 +0000</pubDate>
				<category><![CDATA[New Product]]></category>
		<category><![CDATA[UV-VIS]]></category>
		<guid isPermaLink="false">https://www.barascientific.com/product/?p=4449</guid>

					<description><![CDATA[The Double-beam UV-Vis spectrophotometer offers excellent performance, data compliance, and intuitive operability​ The UV-1900i Plus is a high-performance double-beam UV-Vis spectrophotometer with Shimadzu’s LO-RAY-LIGH™ diffraction grating technology. It offers 1 nm resolution, low stray light and noise, and ultra-fast scanning at 29,000 nm/min. The user-friendly multi-language interface supports various measurement modes, including photometric, spectrum, quantitation, [&#8230;]]]></description>
										<content:encoded><![CDATA[
<h2 class="wp-block-heading">The Double-beam UV-Vis spectrophotometer offers excellent performance, data compliance, and intuitive operability​</h2>



<p>The UV-1900i Plus is a high-performance double-beam UV-Vis spectrophotometer with Shimadzu’s LO-RAY-LIGH<img src="https://s.w.org/images/core/emoji/16.0.1/72x72/2122.png" alt="™" class="wp-smiley" style="height: 1em; max-height: 1em;" /> diffraction grating technology. It offers 1 nm resolution, low stray light and noise, and ultra-fast scanning at 29,000 nm/min. The user-friendly multi-language interface supports various measurement modes, including photometric, spectrum, quantitation, kinetics, time-course, and bio-methods. It ensures high-accuracy quantitative analysis, detects low-concentration components, and complies with Pharmacopeia standards (JP, USP, EP).</p>



<p>With low stray light levels and high reproducibility, the UV-1900i Plus is ideal for accurate analysis of both low and high concentrations. It supports network connectivity for remote data checks (with additional memory) and can operate as a stand-alone unit with a color touch panel or via PC using LabSolutions UV-Vis software. Enhanced by a new CPU, it offers faster response speeds, efficient analysis, and integrated data management.</p>



<figure class="wp-block-image size-large"><img loading="lazy" decoding="async" width="1024" height="242" src="https://www.barascientific.com/product/wp-content/uploads/2025/03/image-8-1024x242.png" alt="" class="wp-image-4450" srcset="https://www.barascientific.com/product/wp-content/uploads/2025/03/image-8-1024x242.png 1024w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-8-300x71.png 300w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-8-768x181.png 768w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-8-1536x363.png 1536w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-8-2048x484.png 2048w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-8-1777x420.png 1777w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-8-696x164.png 696w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-8-1068x252.png 1068w" sizes="auto, (max-width: 1024px) 100vw, 1024px" /></figure>



<h2 class="wp-block-heading">Refined User-Friendliness</h2>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/molecular_spectro/uv/uv1900iPlus/ft_1.png" alt="Refined User-Friendliness"/></figure>



<h3 class="wp-block-heading">Easy-to-Use Interface<br>Grasp the Current Status and Operating Procedures at a Glance</h3>



<p>The UV-1900i Plus on-screen user interface includes large, easy-to-see icons deployed on a black background, so the instrument settings are evident at a glance. In addition, the large, easy-to-see icons&nbsp;improve intuitive understanding, which enables users to quickly become familiar with the operations. Furthermore, the user interface is designed to minimize transitions between windows, so users do not get confused during the operations.&nbsp;The system also features a faster response speed by adopting a new CPU.</p>



<ul class="wp-block-list">
<li></li>
</ul>



<h3 class="wp-block-heading">Easy-to-Use Interface<br>Grasp the Current Status and Operating Procedures at a Glance</h3>



<p>The UV-1900i Plus on-screen user interface includes large, easy-to-see icons deployed on a black background, so the instrument settings are evident at a glance. In addition, the large, easy-to-see icons&nbsp;improve intuitive understanding, which enables users to quickly become familiar with the operations. Furthermore, the user interface is designed to minimize transitions between windows, so users do not get confused during the operations.&nbsp;The system also features a faster response speed by adopting a new CPU.</p>



<figure class="wp-block-image size-large is-resized"><img loading="lazy" decoding="async" width="1024" height="615" src="https://www.barascientific.com/product/wp-content/uploads/2025/03/image-10-1024x615.png" alt="" class="wp-image-4452" style="width:386px;height:auto" srcset="https://www.barascientific.com/product/wp-content/uploads/2025/03/image-10-1024x615.png 1024w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-10-300x180.png 300w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-10-768x461.png 768w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-10-700x420.png 700w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-10-696x418.png 696w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-10.png 1048w" sizes="auto, (max-width: 1024px) 100vw, 1024px" /><figcaption class="wp-element-caption">Display languages are available in eight languages (Japanese, English, Chinese, Spanish, Portuguese, German, French, Russian).</figcaption></figure>



<h2 class="wp-block-heading">Multiple&nbsp;Measurement Modes</h2>



<p>UV-1900i Plus has six basic measurement modes, which offer the optimal solution for a variety of measurements.</p>



<div class="wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex">
<div class="wp-block-column is-layout-flow wp-block-column-is-layout-flow">
<h3 class="wp-block-heading"><strong>Photometric</strong></h3>



<p>Measures the photometric value at a single wavelength or multiple (up to eight) wavelengths.<br>&nbsp;</p>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/molecular_spectro/uv/uv1900iPlus/mmm_1.png" alt="Photometric"/></figure>
</div>



<div class="wp-block-column is-layout-flow wp-block-column-is-layout-flow">
<h3 class="wp-block-heading"><strong>Spectrum</strong></h3>



<p>Measures a sample spectrum using wavelength scanning.<br><br>&nbsp;</p>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/molecular_spectro/uv/uv1900iPlus/mmm_2.png" alt="Spectrum"/></figure>
</div>



<div class="wp-block-column is-layout-flow wp-block-column-is-layout-flow">
<h3 class="wp-block-heading"><strong>Quantitation</strong></h3>



<p>Generates a calibration curve from the measurement of standards, and then calculates the concentrations of unknowns.</p>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/molecular_spectro/uv/uv1900iPlus/mmm_3.png" alt="Quantitation"/></figure>
</div>
</div>


<div class="wp-block-image">
<figure class="aligncenter size-full"><img loading="lazy" decoding="async" width="599" height="362" src="https://www.barascientific.com/product/wp-content/uploads/2025/03/image-11.png" alt="" class="wp-image-4453" srcset="https://www.barascientific.com/product/wp-content/uploads/2025/03/image-11.png 599w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-11-300x181.png 300w" sizes="auto, (max-width: 599px) 100vw, 599px" /></figure></div>


<div class="wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex">
<div class="wp-block-column is-layout-flow wp-block-column-is-layout-flow">
<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/molecular_spectro/uv/uv1900iPlus/mmm_4.png" alt="Kinetics"/></figure>



<h3 class="wp-block-heading"><strong>Kinetics</strong></h3>



<p>Measures absorbance changes as a function of time and obtains the enzymatic activity values. The kinetics measurement method or the rate measurement method can be selected</p>
</div>



<div class="wp-block-column is-layout-flow wp-block-column-is-layout-flow">
<ul class="wp-block-list">
<li><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/molecular_spectro/uv/uv1900iPlus/mmm_5.png" alt="Time Course"><strong>Time Course</strong>Measures changes over time in photometric values at a specified wavelength.</li>
</ul>
</div>



<div class="wp-block-column is-layout-flow wp-block-column-is-layout-flow">
<ul class="wp-block-list">
<li><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/molecular_spectro/uv/uv1900iPlus/mmm_6.png" alt="Biomethod"><strong>Biomethod</strong>Quantifies DNA or protein concentrations.</li>
</ul>
</div>
</div>



<p>* The background color of the operation screen can also be set to white.</p>



<h2 class="wp-block-heading">Various Functions for Comfortable Daily Measurement</h2>



<ul class="wp-block-list">
<li>Assist Function&nbsp;&nbsp;<a href="https://www.shimadzu.com/an/products/brand/analytical_intelligence.html" target="_blank" rel="noopener"></a>The instrument assists the user to ensure that measurements<br>are performed using&nbsp;the correct procedure.<sup>*1</sup>
<ul class="wp-block-list">
<li><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/molecular_spectro/uv/uv1900iPlus/ft3_1.png" alt="Assist Function"></li>
</ul>
</li>
</ul>



<div class="wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex">
<div class="wp-block-column is-layout-flow wp-block-column-is-layout-flow">
<p><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/molecular_spectro/uv/uv1900iPlus/assist_1.png" alt="Assist Function">Checks whether or not baseline correction, auto zero correction or cell blank correction&nbsp;has been performed and informs the user if it has not been.</p>
</div>



<div class="wp-block-column is-layout-flow wp-block-column-is-layout-flow">
<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/molecular_spectro/uv/uv1900iPlus/assist_2.png" alt="Assist Function"/></figure>



<p>Informs the user if the last correction performed is not appropriate for the planned measurement</p>
</div>



<div class="wp-block-column is-layout-flow wp-block-column-is-layout-flow">
<ul class="wp-block-list">
<li><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/molecular_spectro/uv/uv1900iPlus/assist_3.png" alt="Assist Function">Informs the user if the UV-1900i Plus is not ready to begin measurement and&nbsp;when starting measurements<br>and 100 %T (0 Abs) corrections.</li>
</ul>
</div>
</div>



<p>*1 This function can be enabled/disabled.</p>



<h2 class="wp-block-heading">Shutdown Function</h2>



<p>The shutdown function puts UV-1900i Plus to sleep after it&#8217;s been used,&nbsp;or after a certain period of time. Putting the instrument into sleep mode limits power consumption and helps preserve the lamp.</p>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/molecular_spectro/uv/uv1900iPlus/ft2_1.png" alt="Shutdown Function"/></figure>



<h2 class="wp-block-heading">Wakeup Function</h2>



<p>Automatically wakes up a sleeping UV-1900i Plus at a specified time. This function eliminates the need for analysts to wait for it to warm up, allowing them to be more productive.</p>



<figure class="wp-block-image size-full"><img loading="lazy" decoding="async" width="800" height="480" src="https://www.barascientific.com/product/wp-content/uploads/2025/03/image-12.png" alt="" class="wp-image-4459" srcset="https://www.barascientific.com/product/wp-content/uploads/2025/03/image-12.png 800w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-12-300x180.png 300w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-12-768x461.png 768w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-12-700x420.png 700w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-12-696x418.png 696w" sizes="auto, (max-width: 800px) 100vw, 800px" /></figure>



<figure class="wp-block-image size-full"><img loading="lazy" decoding="async" width="986" height="411" src="https://www.barascientific.com/product/wp-content/uploads/2025/03/image-13.png" alt="" class="wp-image-4460" srcset="https://www.barascientific.com/product/wp-content/uploads/2025/03/image-13.png 986w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-13-300x125.png 300w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-13-768x320.png 768w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-13-696x290.png 696w" sizes="auto, (max-width: 986px) 100vw, 986px" /></figure>



<h2 class="wp-block-heading">Startup Validation Function</h2>



<p>Instrument performance checks can be performed automatically　when the instrument is turned ON.<sup>*2</sup><br>This enables even more reliable instrument operation.<br>It can also be implemented in combination with the Wakeup function.</p>



<p>*2 This function can be enabled/disabled.<br>The performance check items that can be used with this function are as follows: wavelength accuracy (D2), wavelength repeat accuracy (D2), degradation, noise level, baseline flatness, baseline stability (drift), [EP] Control of Wavelength Accuracy (D2), and [USP] Control of Wavelengths (D2).</p>



<figure class="wp-block-image size-full"><img loading="lazy" decoding="async" width="326" height="152" src="https://www.barascientific.com/product/wp-content/uploads/2025/03/image-14.png" alt="" class="wp-image-4461" srcset="https://www.barascientific.com/product/wp-content/uploads/2025/03/image-14.png 326w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-14-300x140.png 300w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-14-324x152.png 324w" sizes="auto, (max-width: 326px) 100vw, 326px" /></figure>



<h2 class="wp-block-heading">Network Connectivity Function</h2>



<p>Data can now be transferred to a PC via a network. With wireless printing, multiple UV units can print from a single printer.<sup>*3</sup>&nbsp;(A router and other network equipment must be installed to use a network.)</p>



<figure class="wp-block-image size-large"><img loading="lazy" decoding="async" width="1024" height="393" src="https://www.barascientific.com/product/wp-content/uploads/2025/03/image-15-1024x393.png" alt="" class="wp-image-4462" srcset="https://www.barascientific.com/product/wp-content/uploads/2025/03/image-15-1024x393.png 1024w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-15-300x115.png 300w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-15-768x295.png 768w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-15-1095x420.png 1095w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-15-696x267.png 696w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-15-1068x410.png 1068w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-15.png 1251w" sizes="auto, (max-width: 1024px) 100vw, 1024px" /></figure>



<p>*3 A router with a wireless function is required.<br>*4 Optional expanded memory is required. The instrument is not compatible with control via a network.<br>*5 A PictBridge-compatible printer is required.</p>



<h2 class="wp-block-heading">Bar-Code Reader and Keyboard Entry Function</h2>



<p>Sample names and numerical values can be entered by a bar-code reader or from the keyboard.<br>This saves time when entering sample names for a multiple-sample analysis, and prevents sample misidentification and other human errors.<sup>*6</sup></p>



<figure class="wp-block-image size-full"><img loading="lazy" decoding="async" width="840" height="200" src="https://www.barascientific.com/product/wp-content/uploads/2025/03/image-16.png" alt="" class="wp-image-4463" srcset="https://www.barascientific.com/product/wp-content/uploads/2025/03/image-16.png 840w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-16-300x71.png 300w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-16-768x183.png 768w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-16-696x166.png 696w" sizes="auto, (max-width: 840px) 100vw, 840px" /></figure>



<p><br>*6 Use a bar-code reader and keyboard with a USB connection.</p>



<h2 class="wp-block-heading">High Performance to Meet Diverse Needs</h2>



<h2 class="wp-block-heading">Ultra-Fast Scan</h2>



<p>Spectra can be acquired as fast as 29,000 nm/min. Ultra-fast scanning is effective in tracking chemical reactions in a short time. In addition to the absorbance change at specified wavelengths, spectra can also be acquired in a short time with the UV-1900i Plus. Therefore, more detailed behavior can be investigated by observing spectra with the UV-1900i Plus.<br>The figures below show the analysis of the particle agglomeration process when salts are added to silver nanoparticles. Measurements of the 300 to 700 nm region were performed in ultra-fast scan mode. In addition to the decrease of absorbance at 400 nm and the increase of absorbance at 480 nm, the temporal changes of spectra can also be observed.</p>



<figure class="wp-block-image size-large"><img loading="lazy" decoding="async" width="1024" height="341" src="https://www.barascientific.com/product/wp-content/uploads/2025/03/image-17-1024x341.png" alt="" class="wp-image-4464" srcset="https://www.barascientific.com/product/wp-content/uploads/2025/03/image-17-1024x341.png 1024w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-17-300x100.png 300w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-17-768x256.png 768w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-17-696x232.png 696w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-17-1068x356.png 1068w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-17.png 1200w" sizes="auto, (max-width: 1024px) 100vw, 1024px" /></figure>



<h2 class="wp-block-heading">Low Stray Light</h2>



<p>Linearity will be lost in the high absorbance region due to stray light. UV-1900i Plus is equipped with Low Stray Light Diffraction Gratings, achieve “best-in-class” low stray light. Stray light is at 0.5 % max. (198 nm), making accurate measurements possible at 1 Abs or more, even in the ultraviolet region. In addition, high-concentration samples can be quantified accurately.<br>The figure on the right is a calibration curve for acetic acid, created with absorbance at 200 nm. The correlation coefficient is 0.9998 and correct measured values are obtained even with high-concentration samples.</p>



<figure class="wp-block-image size-full"><img loading="lazy" decoding="async" width="424" height="278" src="https://www.barascientific.com/product/wp-content/uploads/2025/03/image-18.png" alt="" class="wp-image-4465" srcset="https://www.barascientific.com/product/wp-content/uploads/2025/03/image-18.png 424w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-18-300x197.png 300w" sizes="auto, (max-width: 424px) 100vw, 424px" /></figure>



<ul class="wp-block-list">
<li></li>
</ul>



<h2 class="wp-block-heading">High Reproducibility and Repeatability Accuracy</h2>



<p>The photometric repeatability accuracy is 0.0002 Abs max. (0.5 Abs and 1.0 Abs). As a result,&nbsp;variance in the measurement results is suppressed, enabling more accurate quantitation and the detection of low-concentration samples.<br>The figure on the right is a calibration curve for caffeine, created with absorbance at 273 nm.<br>The calibration curve has an Abs = 0.0528 Conc. The lower limit of quantitation determined from the standard deviation is 0.0051 mg/L.</p>



<p>Note: One method of determining the lower limit of quantitation is to use ten times the standard deviation. This is an actual measured value and is not guaranteed.</p>



<figure class="wp-block-table"><table class="has-fixed-layout"><tbody><tr><td>No.</td><td>Absorbance of Blank Solution（273 nm）</td></tr><tr><td>1</td><td>-0.00001</td></tr><tr><td>2</td><td>0.00001</td></tr><tr><td>3</td><td>-0.00002</td></tr><tr><td>4</td><td>0.00002</td></tr><tr><td>5</td><td>0.00001</td></tr><tr><td>6</td><td>-0.00003</td></tr><tr><td>7</td><td>0.00001</td></tr><tr><td>8</td><td>-0.00004</td></tr><tr><td>9</td><td>0.00001</td></tr><tr><td>10</td><td>0.00005</td></tr><tr><td>Standard Deviationσ</td><td>0.000025</td></tr></tbody></table></figure>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/molecular_spectro/uv/uv1900iPlus/ft3_3.png" alt="High Reproducibility and Repeatability Accuracy"/></figure>



<h2 class="wp-block-heading">Validation Functions Compliant with JP, USP, and EP (Touch-screen Display)</h2>



<p>This instrument can not only run checks for nine JIS items, but also those stipulated in the Japanese Pharmacopoeia (JP), United States Pharmacopeia (USP), and the European Pharmacopoeia (EP). The UV-1900 series also complies with the hardware specifications required by each Pharmacopoeia. In addition, the check conditions can be saved. As a result, checks can be performed easily just by calling them up as needed. Check results can also be saved.</p>



<figure class="wp-block-image size-large"><img loading="lazy" decoding="async" width="1024" height="583" src="https://www.barascientific.com/product/wp-content/uploads/2025/03/image-19-1024x583.png" alt="" class="wp-image-4467" srcset="https://www.barascientific.com/product/wp-content/uploads/2025/03/image-19-1024x583.png 1024w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-19-300x171.png 300w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-19-768x438.png 768w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-19-737x420.png 737w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-19-696x397.png 696w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-19-1068x608.png 1068w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-19.png 1348w" sizes="auto, (max-width: 1024px) 100vw, 1024px" /></figure>



<h2 class="wp-block-heading">Improved Security Functions</h2>



<p>An external control security function has been added to provide more support for compliance with regulations. Three user authority levels, &#8220;Administrator&#8221;, &#8220;Developer&#8221;, and &#8220;Operator&#8221;, can be set for instrument users.</p>



<figure class="wp-block-image size-full"><img loading="lazy" decoding="async" width="450" height="270" src="https://www.barascientific.com/product/wp-content/uploads/2025/03/image-20.png" alt="" class="wp-image-4469" srcset="https://www.barascientific.com/product/wp-content/uploads/2025/03/image-20.png 450w, https://www.barascientific.com/product/wp-content/uploads/2025/03/image-20-300x180.png 300w" sizes="auto, (max-width: 450px) 100vw, 450px" /></figure>



<h2 class="wp-block-heading">Resolution of 1 nm, the Highest in its Class</h2>



<p>In addition to achieving a resolution of 1 nm, the highest in its class, by using a monochromator with a Czerny-Turner mounting, the UV-1900i Plus also features a compact, bright optical system. The instrument is more than capable of meeting the wavelength resolution required in the USP and EP.</p>



<h2 class="wp-block-heading">Compatible with Validation from PC Software</h2>



<p>UV validation software (limited function edition) is included as standard. Using this software, inspections can be implemented as stipulated for 9 items in JIS and the JP. If optional UV validation software (USP/EP compatible edition) is added, examinations can be implemented as stipulated in the USP and the EP.</p>



<div class="wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex">
<div class="wp-block-column is-layout-flow wp-block-column-is-layout-flow">
<ul class="wp-block-list">
<li><img loading="lazy" decoding="async" height="302" width="450" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/spectro/uv/1900i/2-4-3_uv_-validation_software.jpg" alt="UV validation software.">
<ul class="wp-block-list">
<li>Inspection results can not only be printed but also saved to a file, so the results can be called up later for confirmation.</li>



<li>The inspection parameters can also be saved to separate files for periodic and routine inspections, and then called up for use.</li>
</ul>
</li>
</ul>
</div>



<div class="wp-block-column is-layout-flow wp-block-column-is-layout-flow">
<ul class="wp-block-list">
<li><img loading="lazy" decoding="async" height="302" width="450" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/spectro/uv/1900i/2-4-4_uv_validation_software.jpg" alt="">
<ul class="wp-block-list">
<li>The user can select confirmation of instrument performance indicators as per JIS K0115 General rules for molecular absorptiometric analysis, as well as the general test methods in the JP. (Order inspection jigs and reagents separately.)<br>Note: Optional validation software is required to support the USP and EP.</li>
</ul>
</li>
</ul>
</div>
</div>



<h2 class="wp-block-heading">Support for FDA 21 CFR Part 11, PIC/S GMP Guidelines and Other Regulations and Guidelines</h2>



<p>Ensuring the integrity of data (database management), including the user management, user authority management, and data audit trails required for compliance with FDA 21 CFR Part 11, PIC/S GMP guidelines, and other ER/ES regulations is possible.</p>



<h2 class="wp-block-heading">Reliable LabSolutions Software</h2>



<p>&nbsp;In addition to LabSolutions UV-Vis, which provides basic functionality, Shimadzu also offers LabSolutions DB UV-Vis and LabSolutions CS UV-Vis to meet the requirements of ER/ES regulations.</p>



<figure class="wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio"><div class="wp-block-embed__wrapper">
<iframe loading="lazy" title="UV 1900i UV-Vis Spectrophotometer" width="696" height="392" src="https://www.youtube.com/embed/wrA1QYj3f1E?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe>
</div></figure>
]]></content:encoded>
					
					<wfw:commentRss>https://www.barascientific.com/product/uv-1900i-plus-uv-vis-spectrophotometer/feed/</wfw:commentRss>
			<slash:comments>1</slash:comments>
		
		
		<media:content url="https://www.youtube.com/embed/wrA1QYj3f1E" medium="video" width="1280" height="720">
			<media:player url="https://www.youtube.com/embed/wrA1QYj3f1E" />
			<media:title type="plain">UV 1900i UV-Vis Spectrophotometer</media:title>
			<media:description type="html"><![CDATA[Winner of the Red Dot Design Awards for Product Design 2019, the UV-1900i double-beam UV-Vis Spectrophotometer uses Shimadzu&#039;s original LO-RAY-LIGH™ diffract...]]></media:description>
			<media:thumbnail url="https://www.barascientific.com/product/wp-content/uploads/2025/07/uv-1900i-uv-vis-spectrophotomete.jpg" />
			<media:rating scheme="urn:simple">nonadult</media:rating>
		</media:content>
	</item>
		<item>
		<title>MAP-100 &#8212; Microplastic automatic preparation device</title>
		<link>https://www.barascientific.com/product/map-100-microplastic-automatic-preparation-device/</link>
					<comments>https://www.barascientific.com/product/map-100-microplastic-automatic-preparation-device/#respond</comments>
		
		<dc:creator><![CDATA[Bara Scientific]]></dc:creator>
		<pubDate>Mon, 01 Jul 2024 07:56:00 +0000</pubDate>
				<category><![CDATA[FTIR]]></category>
		<guid isPermaLink="false">https://www.barascientific.com/product/?p=4192</guid>

					<description><![CDATA[This automatic preparation device isolates microplastics contained in environmental surface water. The presence of microplastics in environmental surface water such as oceans, rivers, and lakes has attracted international attention as an environmental problem, and many monitoring results have been reported.The analysis of microplastics requires multiple steps, including sample collection, digestion and filtration, and qualitative and [&#8230;]]]></description>
										<content:encoded><![CDATA[
<h2 class="wp-block-heading">This automatic preparation device isolates microplastics contained in environmental surface water.</h2>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/ftir/map-100/map100_top.jpg" alt="Microplastic automatic preparation device"/></figure>



<p>The presence of microplastics in environmental surface water such as oceans, rivers, and lakes has attracted international attention as an environmental problem, and many monitoring results have been reported.<br>The analysis of microplastics requires multiple steps, including sample collection, digestion and filtration, and qualitative and quantitative (size, number of particles, mass or concentration) analysis.<br>To accurately analyze microplastics in aqueous samples, an essential step is to isolate the particles from other components in the sample. This process normally involves digestion and separation steps.<br>The MAP-100 automates the typical steps needed to isolate microplastics. This improves the reproducibility of the analytical workflow, enables lab technicians to focus on other tasks, and makes handling of reagents safer.</p>



<h3 class="wp-block-heading">Labor savings</h3>



<p>Automating the complicated preparation process significantly reduces the number of man-hours required.</p>



<h3 class="wp-block-heading">Reproducibility</h3>



<p>Manual tasks by the operator are reduced, enabling highly reproducible preparation.<br>This improves accuracy when comparing data across analysts and laboratories.</p>



<h3 class="wp-block-heading">Safety</h3>



<p>Simplified handling of reagents by operators.</p>



<h2 class="wp-block-heading">Operation of the Automatic Preparation Device</h2>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/ftir/map-100/map100_img01.jpg" alt="Operation of the Automatic Preparation Device"/></figure>



<p>The sample collected from the environmental surface water is placed inside the reaction vessel in the automatic preparation device. The control software is used to configure the conditions for each preparation step via digestion, separation, and overflow. When the preparation process is started, the microplastics are automatically collected through the processes of (1) Digestion, (2) Separation and (3) Filtration as shown below.</p>



<h3 class="wp-block-heading">Automated preparation steps</h3>



<p><strong>[1] Digestion process　Digestion of organic compounds via an hydrogen peroxide solution.</strong></p>



<p><strong>[2] Separation process　Density separation via an sodium iodide solution.</strong></p>



<p><strong>[3] Filtration process　The supernatant fluid discharged by the overflow is filtered out by the collection filter.</strong></p>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/ftir/map-100/map100_img02.jpg" alt="Sample injection"/></figure>



<h2 class="wp-block-heading">Simple Control Software</h2>



<p>The operator configures the conditions for the automated preparation process in the simple software window.<br>The progress during preparation is displayed in a monitoring window, and the estimated completion time can be checked in the status area. This user-friendly control software simplifies the preparation process.</p>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/ftir/map-100/map100_img03.png" alt="Simple Control Software"/></figure>



<p> <strong>
<!--change the width and height value as you want.--> 
<!-- Do change "index.htm" to your real html name of the flippingbook--> 
<iframe  style="width:100%;height:450px"  src="https://www.barascientific.com/product/wp-content/uploads/flipbook/434/book.html"  seamless="seamless" scrolling="no" frameborder="0" allowtransparency="true" allowfullscreen mozallowfullscreen  webkitallowfullscreen ></iframe>
</strong> <br></p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.barascientific.com/product/map-100-microplastic-automatic-preparation-device/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>ICPMS-2040/2050 Series &#8212; ICP Mass Spectrometer</title>
		<link>https://www.barascientific.com/product/icpms-2040-2050-series-icp-mass-spectrometer/</link>
					<comments>https://www.barascientific.com/product/icpms-2040-2050-series-icp-mass-spectrometer/#respond</comments>
		
		<dc:creator><![CDATA[Bara Scientific]]></dc:creator>
		<pubDate>Fri, 06 Oct 2023 11:52:49 +0000</pubDate>
				<category><![CDATA[ICP]]></category>
		<guid isPermaLink="false">https://www.barascientific.com/product/?p=3931</guid>

					<description><![CDATA[Exceptional yet Eco Friendly An advanced mini-torch design, combined with a redesigned collision/reaction cell, and a high-performance quadrupole mass filter result in an environmentally friendly system with superior analytical performance. Proprietary Advanced Mini-Torch System Low Argon Gas Consumption A major drawback of ICP-MS systems is the large argon gas consumption. Shimadzu’s mini-torch system consumes 11 [&#8230;]]]></description>
										<content:encoded><![CDATA[
<ul class="wp-block-list">
<li>An Era Without CompromiseShimadzu’s ICPMS-2040 Series / ICPMS-2050 Series of ICP Mass Spectrometers has achieved a harmonious blend of environmental-friendliness and analytical performance through its advanced proprietary Mini-Torch System. Without the need for any special options, it reduces measurement time, contributing to the optimization of your workflow efficiency. Moreover, the software comes with various functions, options, and maintenance information that minimize operator intervention, revolutionizing the way you work.</li>
</ul>



<h2 class="wp-block-heading">Exceptional yet Eco Friendly</h2>



<p>An advanced mini-torch design, combined with a redesigned collision/reaction cell, and a high-performance quadrupole mass filter result in an environmentally friendly system with superior analytical performance.</p>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/elemental/icp/icpms-2040_2050/icpms-2040_2050_img_features01-01.jpg" alt="Eco Friendly yet Competent"/></figure>



<h3 class="wp-block-heading">Proprietary Advanced Mini-Torch System</h3>



<ul class="wp-block-list">
<li>Redeveloped High Sensitivity Mini-TorchOptimizing the torch design keeps argon gas consumption low and decreases sample flow rate into the plasma, improving sample ionization efficiency. The new design roughly doubles sensitivity compared to previous models while reducing injector clogging issues.</li>



<li></li>
</ul>



<h4 class="wp-block-heading">Low Argon Gas Consumption</h4>



<p>A major drawback of ICP-MS systems is the large argon gas consumption. Shimadzu’s mini-torch system consumes 11 L/min of argon, two-thirds the amount used by typical plasma torches. Continuous operation using a 7 m<sup>3</sup>&nbsp;gas cylinder is up to 10 hours. Utilizing Eco mode (5.5 L/min plasma) during standby can further reduce argon gas consumption.&nbsp;</p>



<h4 class="wp-block-heading">No Need for High-Purity Argon Gas</h4>



<p>ICPMS-2040/2050 Series systems have a Shimadzu-made high-frequency power supply that features high-speed matching functionality, allowing for the use of low-cost, low-purity (99.95 %) argon gas to reliably generate a robust plasma.</p>



<h3 class="wp-block-heading">Redesigned Collision/Reaction Cell</h3>



<h4 class="wp-block-heading">Collision Mode</h4>



<p>Inert helium gas is introduced into the cell to selectively attenuate kinetic energies of polyatomic ions based on their sizes. These low energy ions are removed from the ion beam by applying a bias voltage at the cell exit. Because fewer by-product ions are generated, it can be used for a wide range of applications.</p>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/elemental/icp/icpms-2040_2050/icpms-2040_2050_img_option-08%20.png" alt="Collision Mode"/></figure>



<p>When analyzing&nbsp;<sup>78</sup>Se, ArAr polyatomic ions interfere with it. Since Se and ArAr have different ion sizes, a kinetic energy difference occurs in the cell where He gas is introduced. As a result, Se can be measured with high sensitivity by setting an energy filter where only Se is exceeded*.&nbsp;</p>



<p>*Note:&nbsp;Example of how collision mode can be used.&nbsp;</p>



<h4 class="wp-block-heading">Online Interelement Correction (IEC)</h4>



<p>Shimadzu’s proprietary online interelement correction (IEC) function is used to correct for spectral interference that cannot be eliminated by the collision mode. By only measuring one standard sample an interference correction is calculated and applied to all samples run subsequently.&nbsp;&nbsp;</p>



<h4 class="wp-block-heading">Reaction Mode　</h4>



<p>When a specific gas is introduced into the cell, the reaction of gas with ions will occur to reduce interferences. Target ions can be analyzed with high sensitivity, while both doubly charged ions not eliminated by the collision mode and polyatomic ions can be reduced.</p>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/elemental/icp/icpms-2040_2050/icpms-2040_2050_img_option-07.jpg" alt="Reaction Mode"/></figure>



<p>When analyzing&nbsp;<sup>78</sup>Se, ArAr Polyatomic ions and Gd doubly charged ions interfere. However, charge and proton transfer occur by contacting interfering ions and H<sub>2&nbsp;</sub>gas in the cell in which H<sub>2</sub>&nbsp;gas is introduced. As a result, the target element, m/z=78, can be detected with high sensitivity. This shows how the reaction mode can mitigate the effects of doubly charged ions that cannot be removed by the collision mode*.&nbsp;</p>



<p>*Note:&nbsp;Example of how reaction mode can be used.&nbsp;</p>



<h3 class="wp-block-heading">High-Performance Quadrupole Mass Filter</h3>



<h4 class="wp-block-heading">Charge Stabilizer</h4>



<p>To mitigate ion charge effects on the mass filter, a pulse voltage is applied between the analysis of each mass to maintain a constant charge level at the electrode surface. This improves the signal stability when analyzing samples for long periods (patent pending).</p>



<h4 class="wp-block-heading">High-Resolution Mode and Half-Mass Correction</h4>



<p>Masses can be analyzed at 0.5 u intervals using the high-resolution mode, enabling half-mass correction for doubly charged interferences common in rare earth elements (REEs).</p>



<h2 class="wp-block-heading">High Throughput with No Additional Cost</h2>



<p>The improved gas controller features high-speed cell gas purging. Combined with ProActive Rinsing, measurement times can be significantly shortened without any additional accessories or cost.</p>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/elemental/icp/icpms-2040_2050/icpms-2040_2050_img_features02-01.jpg" alt="Fast at No Additional Cost"/></figure>



<ul class="wp-block-list">
<li>High-Speed Cell Gas PurgingThe redesigned gas controller shortens cell gas introduction and exhaust times (patent pending).</li>



<li></li>
</ul>



<h3 class="wp-block-heading">ProActive Rinsing</h3>



<p>While measuring multiple samples, the rinsing sequence can be started early by sending the autosampler probe to rinse while collecting data using sample already in the suction line. This greatly reduces measurement time and conserves sample.</p>



<h2 class="wp-block-heading">Minimal Operation Required</h2>



<p>With the extended rinsing function, operators do not need to be concerned about carryover that compromises data quality. Preset methods eliminate the need for method development in many applications.</p>



<h3 class="wp-block-heading">Extended Rinsing<br>—Automatically Minimizes Carryover—</h3>



<p>Analyzing samples containing a high concentration of target elements can cause carryover to the&nbsp;next sample, preventing accurate measurements. The extended rinsing function automatically performs an additional rinse sequence when a target element exceeds a predetermined upper limit.&nbsp;A second rinse solution can be used in the additional rinsing sequence to improve rinsing effectiveness.&nbsp;Consequently, carryover is eliminated to ensure high-quality data.&nbsp;</p>



<h3 class="wp-block-heading">Preset Methods</h3>



<p>Preset analytical methods come configured with optimized settings, such as plasma conditions, target elements, mass information, and internal standards, for common ICPMS applications. The ICPMS-2040/2050 Series systems can therefore be used immediately after installation with minimal training.</p>



<figure class="wp-block-table"><table><tbody><tr><th>Environmental<br>testing</th><td>A method for analyzing drinking/tap water and a method for analyzing high matrix samples, such as waste water, are included.</td></tr><tr><th>Foods</th><td>A method for analyzing food samples with low TDS and a method for food samples with high TDS are included.</td></tr><tr><th>Pharmaceuticals</th><td>Methods are included, respectively for ICH Q3D analysis of oral, parenteral, inhalation and cutaneous drugs.</td></tr></tbody></table></figure>



<h3 class="wp-block-heading">Aerosol Dilution System</h3>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/elemental/icp/icpms-2040_2050/icpms-2040_2050_img_features03-02.jpg" alt="Aerosol Dilution System"/></figure>



<p>Aerosol Dilution System</p>



<p>By introducing argon gas between the chamber and the torch, samples with high TDS (total dissolved solids), such as seawater, are diluted and introduced directly into the plasma.</p>



<h3 class="wp-block-heading">LabSolutions<img src="https://s.w.org/images/core/emoji/16.0.1/72x72/2122.png" alt="™" class="wp-smiley" style="height: 1em; max-height: 1em;" /> ICPMS Ver. 2</h3>



<p>The new version of LabSolutions ICPMS software displays all necessary information in a single&nbsp;window, simplifying operation for new users. Experienced users can utilize advanced configurable&nbsp;settings for challenging applications, in-depth research and all analyses in between.</p>



<figure class="wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio"><div class="wp-block-embed__wrapper">
<iframe loading="lazy" title="[ICP] ICP Mass Spectrometer | ICPMS-2040/2050 series | Official Product Video" width="696" height="392" src="https://www.youtube.com/embed/zr7rcuTh4Z0?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe>
</div></figure>



<p> <strong>
<!--change the width and height value as you want.--> 
<!-- Do change "index.htm" to your real html name of the flippingbook--> 
<iframe  style="width:100%;height:450px"  src="https://www.barascientific.com/product/wp-content/uploads/flipbook/400/book.html"  seamless="seamless" scrolling="no" frameborder="0" allowtransparency="true" allowfullscreen mozallowfullscreen  webkitallowfullscreen ></iframe>
</strong> </p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.barascientific.com/product/icpms-2040-2050-series-icp-mass-spectrometer/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<media:content url="https://www.youtube.com/embed/zr7rcuTh4Z0" medium="video" width="1280" height="720">
			<media:player url="https://www.youtube.com/embed/zr7rcuTh4Z0" />
			<media:title type="plain">[ICP] ICP Mass Spectrometer | ICPMS-2040/2050 series | Official Product Video</media:title>
			<media:description type="html"><![CDATA[An Era Without CompromiseShimadzu’s ICPMS-2040 Series / ICPMS-2050 Series of ICP Mass Spectrometers has achieved a harmonious blend of environmental-friendli...]]></media:description>
			<media:thumbnail url="https://www.barascientific.com/product/wp-content/uploads/2023/10/ICPMS-2040-Series.jpg" />
			<media:rating scheme="urn:simple">nonadult</media:rating>
		</media:content>
	</item>
		<item>
		<title>AIRsight &#8212; Infrared Spectroscopy and Raman Spectroscopy</title>
		<link>https://www.barascientific.com/product/airsight-infrared-spectroscopy-and-raman-spectroscopy/</link>
					<comments>https://www.barascientific.com/product/airsight-infrared-spectroscopy-and-raman-spectroscopy/#respond</comments>
		
		<dc:creator><![CDATA[Bara Scientific]]></dc:creator>
		<pubDate>Thu, 13 Jul 2023 11:23:40 +0000</pubDate>
				<category><![CDATA[UV-VIS]]></category>
		<guid isPermaLink="false">http://www.barascientific.com/product/?p=3391</guid>

					<description><![CDATA[Infrared and Raman Microscope Based on a Combination of Two Analytical Techniques to Provide Complementary Molecular Information. This simple system improves the efficiency of analytical operations by making it easy to perform all process steps from sample observation to data analysis. Examples of Problems Solved &#160;Contaminant components cannot be identified with an infrared microscope alone. [&#8230;]]]></description>
										<content:encoded><![CDATA[
<p>Infrared and Raman Microscope Based on a Combination of Two Analytical Techniques to Provide Complementary Molecular Information.</p>



<p>This simple system improves the efficiency of analytical operations by making it easy to perform all process steps from sample observation to data analysis.</p>



<h3 class="wp-block-heading">Examples of Problems Solved</h3>



<p>&nbsp;Contaminant components cannot be identified with an infrared microscope alone.</p>



<p>&nbsp;The contaminant was identified based on both infrared and Raman measurement results.&nbsp;Measuring the same sample location with both infrared and Raman is desired.</p>



<p>&nbsp;The infrared and Raman microscope enabled the same location to be quickly measured without moving the sample.&nbsp;The target area is too small to be measured with an infrared microscope.</p>



<p>&nbsp;The infrared and Raman microscope enabled even smaller areas to be targeted and measured.&nbsp;Detailed analysis of both organic and inorganic components is desired.</p>



<p>&nbsp;Combining infrared and Raman spectroscopy enabled material analysis.</p>



<h2 class="wp-block-heading">Both FTIR and Raman Spectra Can Be Measured without Moving Samples</h2>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/molecular_spectro/raman_spectro/AIRsight/ft-img01.png" alt="Both FTIR and Raman Spectra Can Be Measured without Moving Samples"/></figure>



<p>Because samples do not need to be moved, both infrared and Raman spectra can be measured from the same position in an extremely small area. That means information about both organic and inorganic substances can be obtained from the same position, which can signiﬁcantly improve the accuracy of qualitative analysis. In addition, Shimadzu’s proprietary wide-view camera and microscope camera (for infrared measurements) or objective lens (for Raman measurements) help improve sample observation efﬁciency. The wide-view camera not only enables observation of large areas up to 10 × 13 mm, but it also supports variable digital zooming. Furthermore, it shares positional information with the microscope camera and objective lenses.<br>The microscope camera can be used to observe areas as small as 30 × 40 μm, the 50× objective lens to observe areas as small as 15 × 20 μm, and the 100× objective lens to observe extremely small areas as small as 7.5 × 10 μm.</p>



<h2 class="wp-block-heading">One Software to Measure and Analyze Both FTIR and Raman Spectra</h2>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/molecular_spectro/raman_spectro/AIRsight/ft-img02.png" alt="One Software to Measure and  Analyze Both FTIR and Raman Spectra"/></figure>



<p>You can easily switch between infrared and Raman measurements with a click. In addition, infrared and Raman spectra can be superimposed and displayed, and various analyses can be performed.</p>



<h2 class="wp-block-heading">Obtain Organic and Inorganic Information with One Instrument</h2>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/molecular_spectro/raman_spectro/AIRsight/ft-img03.png" alt="Obtain Organic and Inorganic Information with One Instrument"/></figure>



<p>Infrared microscopes can analyze organic substances, but it is difﬁcult to obtain information for many inorganic substances.<br>On the other hand, Raman microscopes can obtain information about inorganic substances such as titanium oxide and carbon, in addition to organic substances. In contrast, a single AIRsight unit can analyze mixtures of both organic and inorganic substances.</p>



<h2 class="wp-block-heading">AIRsight Features for Raman Measurements</h2>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/molecular_spectro/raman_spectro/AIRsight/ft-img04.png" alt="Confocal optical system used"/></figure>



<p><strong>Confocal optical system used</strong><br>Enables Raman measurements with excellent spatial resolution<br><br><strong>Equipped standard with 532 nm and 785 nm lasers</strong><br>Characteristics of the lasers<br>532 nm : Light scatters more easily, making it easier to obtain peak intensities.<br>785 nm : Less affected by fluorescence, making it more suitable for fluorescent samples.</p>



<p><strong>Systems can be equipped with either a 50× or 100× objective lens (or both)</strong><br>Selectable depending on the target measurement area</p>



<p><strong>Includes XYZ correction for lens switching between infrared and Raman measurements</strong><br>Enables both infrared and Raman measurements from the same location.</p>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/molecular_spectro/raman_spectro/AIRsight/ft-img05.png" alt="2in1 solution"/></figure>



<h3 class="wp-block-heading">Length Measurement Function</h3>



<ul class="wp-block-list"><li>&nbsp; Infrared&nbsp;&nbsp;&nbsp; &nbsp;&nbsp; Raman&nbsp;&nbsp;<br><br>AMsolution software now includes functionality for measuring lengths, including the lengths of objects in infrared Raman microscope images. Also, length measurement results can be output with a single button click.</li><li></li></ul>



<h3 class="wp-block-heading">Depth Measurements</h3>



<ul class="wp-block-list"><li>&nbsp; Raman&nbsp;&nbsp;<br><strong>Enables Analysis in the Depth Direction (Z-Direction)</strong><br><br>Raman measurements can measure depth either at a single point or along a line*. If a transparent sample, such as plastic or glass, has a thickness (depth) dimension, the laser light components that can penetrate the sample can be used to measure the sample interior. Even if the sample is colored or cloudy, measurements are generally possible as long as the interior can be observed.<br><br>* Measuring depth (at a line) requires using a separate mapping program (P/N 206-35093-41).</li><li></li></ul>



<h2 class="wp-block-heading">AMsolution</h2>



<p>AMsolution includes measurement software (AMsolution Measurement) and analysis software (AMsolution Analysis). The measurement software can control both infrared and Raman measurements via the same window. That means all processes, from image acquisition to measuring infrared and Raman spectra at the same location can be performed smoothly. The analysis software can overlay and search infrared and Raman spectra, create libraries, and so on.<br>The data measured in infrared mode can be imported to LabSolutions IR and analyzed.*¹<br>The data measured with AIMsolution, a software program for infrared microscopes, can be analyzed with AMsolution, a software program for AIRsight.<br>*1 Only with LabSolutions IR Ver. 2.31 or later<br>&nbsp;</p>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/molecular_spectro/raman_spectro/AIRsight/ft-img08.png" alt="AMsolution"/></figure>



<h3 class="wp-block-heading">Instrument Validation</h3>



<p>A validation program is included as standard with the AMsolution measurement program for inspecting and validating the performance of Shimadzu infrared and Raman microscopes. The infrared mode is validated using a polystyrene ﬁlm in accordance with the Japanese Pharmacopoeia, US Pharmacopeia, European Pharmacopoeia, and Chinese Pharmacopoeia. The Raman mode is validated using polystyrene pellets to inspect wavenumber accuracy in accordance with the Japanese Pharmacopoeia, US Pharmacopeia, and European Pharmacopoeia. That means analysts can inspect the basic performance of the instrument themselves to ensure that highly reliable data is obtained.</p>



<ul class="wp-block-list"><li><strong>Infrared Mode Inspection Parameters</strong></li><li><strong>Raman Mode Inspection Parameters</strong></li></ul>



<ul class="wp-block-list"><li><ul><li>Shape and size of the power spectrum</li><li>Based on the polystyrene film spectrum:<br>&#8211; Resolution<br>&#8211; Wavenumber accuracy<br>&#8211; Wavenumber reproducibility<br>&#8211; Transmittance (or absorbance) reproducibility<br>&#8211; Peak resolution function<br>&nbsp;</li><li>Note:<br>・ The wavenumber reproducibility is an inspection parameter only required for the Japanese Pharmacopoeia.<br>・ The Peak resolution function is an inspection parameter only required for the&nbsp;Chinese Pharmacopoeia.<br>・ The inspection parameter of US Pharmacopeia is only wavenumber accuracy.</li></ul></li><li><ul><li>Based on the polystyrene pellet spectrum:<br>&#8211; Wavenumber accuracy</li></ul></li></ul>



<h3 class="wp-block-heading">Library Creation Function</h3>



<p>The functionality for creating libraries is included as standard with the AMsolution analysis program. Analysts can create their own library by registering the infrared and Raman spectra they acquire. Created libraries can also be used for searches. Registering the materials used in products and the substances used in manufacturing processes and using them as a library can improve the accuracy of searches.<br>&nbsp;</p>



<h4 class="wp-block-heading">Libraries Containing about 12,000 Spectra</h4>



<p>​Systems are equipped standard with an extensive selection of libraries, including proprietary Shimadzu libraries and libraries for substances ranging from typical reagents to macromolecules. That means the standard configuration provides plenty of data for qualitative analysis without purchasing additional libraries.<br><strong>​Main Contents</strong><strong>Shimadzu Food Additives library<br>（substances listed in official analysis methods for food additives）</strong><strong>General reagents</strong><strong>Pharmaceuticals</strong><strong>Pesticides</strong><strong>Polymers</strong><strong>Inorganic substances</strong></p>



<p>Total of about 12,000 spectra</p>



<p><a href="https://www.shimadzu.com/an/products/raman/infrared-raman-microscope/airsight/option.html#opt_2" target="_blank" rel="noopener">Option Library</a></p>



<p>Wiley Raman spectrum libraries can be added. Wiley offers libraries of spectra from a wide range of compounds, including monomers, polymers, inorganic compounds, and compounds related to biochemistry or forensic chemistry.</p>



<p><strong>Database example</strong></p>



<figure class="wp-block-table"><table class=""><tbody><tr><th>Product Name</th><th>Database Code</th><th>Number of Spectra</th></tr><tr><td>Sadtler Controlled &amp; Prescription Drugs 1-2</td><td>RZ, RZ2</td><td>1,850</td></tr><tr><td>Sadtler Flavors &amp; Fragrances</td><td>FFR</td><td>600</td></tr><tr><td>Sadtler Inorganics</td><td>RI</td><td>1,630</td></tr><tr><td>Sadtler Polymers &amp; Monomers (Basic) 1</td><td>QR</td><td>1,680</td></tr><tr><td>Sadtler Polymers &amp; Processing Chemicals</td><td>RA</td><td>495</td></tr><tr><td>Sadtler Standards 1-6</td><td>RST1, RST2, RST3,<br>RST4, RST5, RST6</td><td>6,000</td></tr><tr><td>KnowItAll Raman Spectral Library<br>(Annual Subscription)</td><td>&#8211;</td><td>25,000</td></tr></tbody></table></figure>



<h3 class="wp-block-heading">Automatic Contaminant Recognition System</h3>



<ul class="wp-block-list"><li>The functionality for automatically recognizing contaminants is included as standard. The analyst simply clicks one button for the software to automatically recognize contaminants. Two types are available for the infrared mode: the standard type or the micro type for extremely small areas, which can be selected based on the purpose of analysis. Samples can either be measured with the automatically selected measurement positions left unchanged or the analyst can add or delete measurement positions. A sample image is automatically saved for each measured spectrum. That makes it easy to conﬁrm the sample or measurement positions later.</li></ul>



<figure class="wp-block-embed-youtube wp-block-embed is-type-video is-provider-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio"><div class="wp-block-embed__wrapper">
<iframe loading="lazy" title="Infrared and Raman Microscope AIRsight   [Introduction]" width="696" height="392" src="https://www.youtube.com/embed/T4E11HBWvLo?feature=oembed&#038;enablejsapi=1" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe>
</div></figure>



<p> <strong>
<!--change the width and height value as you want.--> 
<!-- Do change "index.htm" to your real html name of the flippingbook--> 
<iframe  style="width:100%;height:450px"  src="https://www.barascientific.com/product/wp-content/uploads/flipbook/215/book.html"  seamless="seamless" scrolling="no" frameborder="0" allowtransparency="true" allowfullscreen mozallowfullscreen  webkitallowfullscreen ></iframe>
</strong> </p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.barascientific.com/product/airsight-infrared-spectroscopy-and-raman-spectroscopy/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<media:content url="https://www.youtube.com/embed/T4E11HBWvLo" medium="video" width="1280" height="720">
			<media:player url="https://www.youtube.com/embed/T4E11HBWvLo" />
			<media:title type="plain">Infrared and Raman Microscope AIRsight   [Introduction]</media:title>
			<media:description type="html"><![CDATA[Infrared Raman Microscopy AIRsight is a microscope system that can perform two analytical methods, infrared spectroscopy and Raman spectroscopy, in the same ...]]></media:description>
			<media:thumbnail url="https://www.barascientific.com/product/wp-content/uploads/2025/07/infrared-and-raman-microscope-ai.jpg" />
			<media:rating scheme="urn:simple">nonadult</media:rating>
		</media:content>
	</item>
		<item>
		<title>AIMsight &#8212; Infrared Microscope</title>
		<link>https://www.barascientific.com/product/aimsight-infrared-microscope/</link>
					<comments>https://www.barascientific.com/product/aimsight-infrared-microscope/#respond</comments>
		
		<dc:creator><![CDATA[Bara Scientific]]></dc:creator>
		<pubDate>Thu, 13 Jul 2023 11:13:25 +0000</pubDate>
				<category><![CDATA[UV-VIS]]></category>
		<guid isPermaLink="false">http://www.barascientific.com/product/?p=3387</guid>

					<description><![CDATA[SHIMADZU AlMs to provide analysis systems for all users. An automatic analysis system that can be used with confidence from your first analysisEquipped as standard with enhanced functionality to support analyses AIMsight, the Analytical Intelligence logo, LabSolutions, IRXross, and IRTracer are trademarks of Shimadzu Corporation or its affiliated companies in Japan and/or other countries.&#160; Observe [&#8230;]]]></description>
										<content:encoded><![CDATA[
<h2 class="wp-block-heading">SHIMADZU AlMs to provide analysis systems for all users.</h2>



<p>An automatic analysis system that can be used with confidence from your first analysis<br>Equipped as standard with enhanced functionality to support analyses</p>



<p>AIMsight, the Analytical Intelligence logo, LabSolutions, IRXross, and IRTracer are trademarks of Shimadzu Corporation or its affiliated companies in Japan and/or other countries.&nbsp;</p>



<h2 class="wp-block-heading">Observe</h2>



<h3 class="wp-block-heading">Loading Samples Is Easy</h3>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/molecular_spectro/raman_spectro/AIMsight/aim_ft_5.png" alt="Load Sample"/></figure>



<p>Pressing the [Eject Sample] button makes it easy to load and remove samples by automatically lowering the stage and switching the objectives to expand space. Furthermore, the lower Condenser mirror can be removed to enable reflectance/ATR measurements of samples up to 40 mm thick.</p>



<h3 class="wp-block-heading">Look for the Item to be Measured<br>-Quickly Determine the Measurement Position-</h3>



<p><strong>Wide-Field Camera and Microscope Camera</strong></p>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/molecular_spectro/raman_spectro/AIMsight/aim_ft_6.png" alt="Look for the Item to be Measured"/></figure>



<p>The wide-field camera and microscope camera help observe samples efficiently. In addition to observing a large area up to 10 × 13 mm, the wide-field camera also supports variable digital zooming. Furthermore, by sharing positional information with the microscope camera, it achieves a digital zoom function capable of zooming to a magnification of about 330× for observing areas as small as 30 × 40 µm. (The microscope camera supports variable digital zoom magnifications up to 10×.)</p>



<h3 class="wp-block-heading">Perform Infrared Measurements Smoothly While Viewing Visible Images<br>&#8211; Visible/Infrared Dual View System &#8211;</h3>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/molecular_spectro/raman_spectro/AIMsight/img_dual.jpg" alt="Dual View System"/></figure>



<p>Infrared spectra can be measured while checking a visible image of the sample. Spectra can be measured while confirming the position of objects, which avoids the trouble of switching back and forth between visible light and infrared light. Used in combination with the tiling function, visible observations, and infrared measurements can be performed anywhere within the stage operating range, eliminating the need to reposition the sample.</p>



<p>Image view of the visible light and infrared optical path<br>&nbsp; &nbsp; &nbsp; &nbsp;&nbsp;&nbsp;&nbsp;<strong>Green light:&nbsp;</strong>visible light optical path<br>&nbsp; &nbsp; &nbsp; &nbsp;&nbsp;&nbsp;&nbsp;<strong>Red light :&nbsp;</strong>infrared optical path&nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</p>



<h2 class="wp-block-heading">Measure</h2>



<h3 class="wp-block-heading">Automatic Contaminant Recognition System</h3>



<figure class="wp-block-image"><a href="https://www.shimadzu.com/an/products/brand/analytical_intelligence.html" target="_blank" rel="noopener"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/ai/ai.jpg" alt="ANALYTICAL INTELLIGENCE"/></a></figure>



<ul class="wp-block-list"><li>The functionality for automatically recognizing objects is included standard. The analyst simply clicks one button for the software to automatically recognize objects. Two types are available: the standard type or the micro type for extremely small areas, which can be selected based on the purpose of analysis. Samples can either be measured with the automatically selected measurement positions left unchanged or the analyst can add or delete measurement positions. A sample image is automatically saved for each measured spectrum. That makes it easy to conﬁrm the sample or measurement positions later.</li><li></li></ul>



<h3 class="wp-block-heading">Perform Ultra Micro Analysis&nbsp; &#8211; Best-in-Class S/N Ratio-</h3>



<p>The AIMsight has been optimized to measure extremely small areas. The AIMsight achieves a 30,000:1 S/N ratio, the best in its class. Consequently, it can quickly obtain excellent spectra from even microscopic objects.</p>



<p><strong>Transmission measurement of polystyrene beads</strong><br><br>A ø10 μm polystyrene bead was measured by transmission method. Low noise and a high-quality spectrum of a very small sample were obtained with only a small number of scans.</p>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/molecular_spectro/raman_spectro/AIMsight/aim_ft_2.png" alt="Perform Ultra Micro Analysis"/></figure>



<h3 class="wp-block-heading">High-Sensitivity ATR Measurement&nbsp; &#8211; Samples with High Refractive Index &#8211;</h3>



<p>Due to a steep incident angle for the infrared light, the AIMsight is able to acquire excellent distortion-free ATR spectra even when measuring samples with a high refractive index, such as black rubber. In addition, the Ge prism (P/N 206-32600-41) has an anti-reflective coating that provides high sensitivity.</p>



<p><strong>ATR measurement of black rubber</strong><br>An acrylonitrilebutadiene rubber (NBR) with 50 wt% carbon was measured with a&nbsp;<br>Ge-ATR objective. A clear peak of C=C-H out-of-plane bending mode was obtained at 970 cm<sup>-1</sup>, which was strained with a gradual incident angle.&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</p>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/molecular_spectro/raman_spectro/AIMsight/aim_ft_3.png" alt="High-sensitivity ATR measurements"/></figure>



<h3 class="wp-block-heading">Length Measurement Function</h3>



<p>A length measurement function has been added to AMsolution. The length of the target object can now be measured in images obtained with the infrared microscope.<br>In addition, with a single click, the length measurement results can be output as a report.</p>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/molecular_spectro/raman_spectro/AIMsight/aim_ft_4.jpg" alt="Length Measurement Function"/></figure>



<h2 class="wp-block-heading">Analyze</h2>



<h3 class="wp-block-heading">Fully Supports the Identification of Contaminants</h3>



<p>Various libraries are available, such as Contaminant Library, Thermally-Damaged and UV-Damaged Plastic Library.</p>



<ul class="wp-block-list"><li><strong>Contaminant Library for LabSolutions IR</strong></li><li><strong>Thermally-Damaged&nbsp;Plastics Library</strong></li><li><strong>UV-Damaged&nbsp;Plastics Library</strong></li></ul>



<h3 class="wp-block-heading">Automatic Identification of Object<br>-Contaminant Analysis Program-</h3>



<h3 class="wp-block-heading"><a href="https://www.shimadzu.com/an/products/brand/analytical_intelligence.html" target="_blank" rel="noopener"></a></h3>



<p>The contaminant analysis program &#8211; the functionality for automatically qualifying objects &#8211; is included as a standard feature in LabSolutions<img src="https://s.w.org/images/core/emoji/16.0.1/72x72/2122.png" alt="™" class="wp-smiley" style="height: 1em; max-height: 1em;" /> IR software. Measured spectra using AMsolution can be loaded directly into LabSolutions IR and analyzed. The contaminant analysis program identiﬁes measured objects with high precision using a spectral library for substances commonly detected as contaminants in combination with Shimadzu&#8217;s proprietary identiﬁcation algorithm&nbsp;(patent JP5205918). Even if objects are mixtures, the system searches for the primary and secondary components and displays the probability of the substances identiﬁed. It is not necessary to specify the number of components in the mixture, so analysis is easy, even for people with little experience with infrared analysis.</p>



<h3 class="wp-block-heading">Spectrum Advisor Function (patent pending)</h3>



<figure class="wp-block-image"><a href="https://www.shimadzu.com/an/products/brand/analytical_intelligence.html" target="_blank" rel="noopener"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/ai/ai.jpg" alt="ANALYTICAL INTELLIGENCE"/></a></figure>



<p>This is packaged with operations specific to infrared microscopes and advice on troubleshooting using accessories. Corrective measures are proposed by comparing the measured spectrum with measurement examples. As a result, better-quality data can be acquired.</p>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/molecular_spectro/raman_spectro/AIMsight/aim_ft_specad.png" alt="Spectrum Adviser"/></figure>



<h3 class="wp-block-heading">Visualize Components- Chemical Imaging* &#8211;</h3>



<p>The invisible distribution of chemicals can be visualized based on peak height or area, multivariate analysis (PCR/MCR), or spectral similarity to target spectra.</p>



<h4 class="wp-block-heading">Chemical image of pharmaceutical powder</h4>



<p>Pharmaceutical products were rolled with a diamond cell, then mapping measurement was performed. The figure to the right represents the distribution of powder components, such as lactose, lipid, and cellulose. The color display can be switched freely between single-color and multi-color.<br>&nbsp;</p>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/molecular_spectro/raman_spectro/AIMsight/aim_ft_9_1.png" alt="Chemical image of a pharmaceutical powder"/></figure>



<p>* Visualizing chemicals requires an optional mapping program (P/N 206-35093-41).</p>



<figure class="wp-block-embed-youtube wp-block-embed is-type-video is-provider-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio"><div class="wp-block-embed__wrapper">
<iframe loading="lazy" title="[FTIR] Infrared Microscope AIMsight Official Product Video" width="696" height="392" src="https://www.youtube.com/embed/gGhhgbTl3uY?feature=oembed&#038;enablejsapi=1" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe>
</div></figure>



<p> <strong>
<!--change the width and height value as you want.--> 
<!-- Do change "index.htm" to your real html name of the flippingbook--> 
<iframe  style="width:100%;height:450px"  src="https://www.barascientific.com/product/wp-content/uploads/flipbook/214/book.html"  seamless="seamless" scrolling="no" frameborder="0" allowtransparency="true" allowfullscreen mozallowfullscreen  webkitallowfullscreen ></iframe>
</strong> </p>



<p><br></p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.barascientific.com/product/aimsight-infrared-microscope/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<media:content url="https://www.youtube.com/embed/gGhhgbTl3uY" medium="video" width="1280" height="720">
			<media:player url="https://www.youtube.com/embed/gGhhgbTl3uY" />
			<media:title type="plain">[FTIR] Infrared Microscope AIMsight Official Product Video</media:title>
			<media:description type="html"><![CDATA[SHIMADZU AlMs to provide analysis systems for all users.This instrument easily and automatically measures micro targets by irradiating them with infrared ray...]]></media:description>
			<media:thumbnail url="https://www.barascientific.com/product/wp-content/uploads/2025/07/ftir-infrared-microscope-aimsigh.jpg" />
			<media:rating scheme="urn:simple">nonadult</media:rating>
		</media:content>
	</item>
		<item>
		<title>Tm Analysis System &#8212; UV1900i/ UV2600i /UV2700i</title>
		<link>https://www.barascientific.com/product/tm-analysis-system-tm-analysis-system/</link>
					<comments>https://www.barascientific.com/product/tm-analysis-system-tm-analysis-system/#respond</comments>
		
		<dc:creator><![CDATA[Bara Scientific]]></dc:creator>
		<pubDate>Thu, 13 Jul 2023 11:00:11 +0000</pubDate>
				<category><![CDATA[UV-VIS]]></category>
		<guid isPermaLink="false">http://www.barascientific.com/product/?p=3383</guid>

					<description><![CDATA[Tm Analysis System Tm analysis systems can accelerate the development process and improve the quality of oligonucleotide therapeutics. Control by LabSolutionsTM&#160;software enables compliance with ER/ES-related regulatory requirements and improves the efficiency of analyzing the thermal stability (Tm analysis) of nucleic acids. What is Tm Analysis System Tm analysis serves an important role in checking the [&#8230;]]]></description>
										<content:encoded><![CDATA[
<h2 class="wp-block-heading">Tm Analysis System</h2>



<p>Tm analysis systems can accelerate the development process and improve the quality of oligonucleotide therapeutics. Control by LabSolutions<sup>TM</sup>&nbsp;software enables compliance with ER/ES-related regulatory requirements and improves the efficiency of analyzing the thermal stability (Tm analysis) of nucleic acids.</p>



<h3 class="wp-block-heading">What is Tm Analysis System</h3>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/lifescience/dnarna/tm_analysis_system/ov_1.png" alt="tm analysis"/></figure>



<p>Tm analysis serves an important role in checking the thermal stability and sequence of nucleic acids. In Tm analysis, heat is applied to the nucleic acids in double-strands. Then, the change in absorbance (melting curve) that occurs as the temperature increases and the strands dissociate into single strands is measured. The melting temperature (Tm value) is determined as the temperature where the mole fractions of single and double strands are equal.</p>



<p>LabSolutions, TMSPC and the Analytical Intelligence logo are trademarks of Shimadzu Corporation or its affiliated companies in Japan and/or other countries.<br>Excel is either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries.<br></p>



<h2 class="wp-block-heading">Reliable Data Integrity</h2>



<h3 class="wp-block-heading">System Configuration</h3>



<p>Tm analysis system consists of the following.</p>



<ul class="wp-block-list"><li>UV-Vis Spectrophotometer</li><li>TMSPC<sup>TM</sup>-8i 8-cell thermoelectrically temperature controlled&nbsp;cell holder</li><li>LabSolutions UV-Vis Tm software</li></ul>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/lifescience/dnarna/tm_analysis_system/tm-ft_1.png" alt="tm analysis"/></figure>



<h3 class="wp-block-heading">Data Integrity</h3>



<p>Tm analysis systems comprise a spectrophotometer, TMSPC-8i 8-cell thermoelectrically temperature-controlled cell holder, and LabSolutions UV-Vis Tm software. They can automatically determine Tm values based on melting curve measurements using the average method or derivative method. LabSolutions UV-Vis Tm can provide the industry’s highest data integrity levels when linked to a LabSolutions DB/CS system, which has an extensive track record from use with LC, GC, and many other analytical instruments.</p>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/lifescience/dnarna/tm_analysis_system/tn-ft_1_2.png" alt="Data Integrity"/></figure>



<p>Note: LabSolutions DB UV-Vis: This is a stand-alone database management system that analysis software on a single PC.<br>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; LabSolutions CS system: A server, client, and acquisition controller are connected on the network. The data of all devices are centrally managed by the database built on the server. User and permission management is centrally managed with this system.</p>



<h2 class="wp-block-heading">Functionality for Satisfying Various Needs</h2>



<h3 class="wp-block-heading">8-Cell Micro Multi-Cell</h3>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/lifescience/dnarna/tm_analysis_system/tm-ft_2_1.png" alt="Melting curve of nucleic acid"/></figure>



<p>Melting Curve of Nucleic Acid (M13 Primer)<br>(Using Micro Multi-Cell with 1 mm Optical Path Length)&nbsp;</p>



<p>This micro multi-cell can be used to measure eight samples at the same time using the same measurement conditions.<br>In addition to previous micro multi-cell models with a 10 mm optical path length (with a 100 μL minimum sample volume) for satisfying high-sensitivity measurement needs, a new model with a 1 mm optical path length (with a 10 μL minimum sample volume) for measuring micro-quantities of expensive samples has been added to the lineup. Cells with a 1 mm optical path length can result in sample evaporation problems, but a new sealing method*, which suppresses the evaporation of samples by sealing the top side of the cell, enables reliable measurement of samples with high melting temperatures.</p>



<p>*The sealing method was supported by Professor Junji Kawakami (Department of Nanobiochemistry, Faculty of Frontiers of Innovative Research in Science and Technology (FIRST), Konan University, Japan). This was supported by AMED under Grant Number JP21ae0121022, JP21ae0121023, JP21ae0121024 (Project leader: Satoshi Obika).</p>



<h3 class="wp-block-heading">Real-Time Transfer Function and Thermodynamic Parameter Analysis</h3>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/lifescience/dnarna/tm_analysis_system/tm-ft_2_3.png" alt="Real-Time Transfer Function and Thermodynamic Parameter Analysis"/></figure>



<p>LabSolutions UV-Vis Tm can transfer temperature, absorbance, and time values to an Excel® file in real-time during measurements.<br>By transferring Tm values obtained from samples with different concentration levels to commercial spreadsheet software, changes in Gibbs free energy values used as an index for drug activity levels or thermodynamic properties, such as entropy or enthalpy, can be analyzed easily.</p>



<h2 class="wp-block-heading">Efficient Automated Workflow</h2>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/lifescience/dnarna/tm_analysis_system/tm-ft_3_1.png" alt="tm analysis"/></figure>



<figure class="wp-block-image"><a href="https://www.shimadzu.com/an/products/brand/analytical_intelligence.html" target="_blank" rel="noopener"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/gc/2030/2107update/test/ana_inte_logo.png" alt="ANALYTICAL INTELLIGENCE"/></a></figure>



<p>Conventional Tm analysis requires multiple steps, including checking the UV-Vis spectrum, annealing, measuring the melting curve, and analyzing data, with recording and data management performed separately. In the past, the spectrum measurement, annealing, and melting curve data were discrete. LabSolutions UV -Vis Tm software supports the entire process from measurement to analysis (Tm value calculation) with a menu that is easy to understand, even for those new to Tm analysis. It achieves a seamless workflow and efficient Tm analysis by performing time-consuming annealing, correction (background wavelength and temperature blank correction), and Tm value calculation (average or derivative methods) steps automatically. In addition, measurement data and analysis values are saved as a set, and various settings and operation histories are managed by an Audit Trail Log.</p>



<h3 class="wp-block-heading">Measuring a sample spectrum</h3>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/lifescience/dnarna/tm_analysis_system/tm-ft_3_2.png" alt="measuring sample spectrum"/></figure>



<p>Set the sample and measure the spectrum.</p>



<p><br>■&nbsp;Spectrum data and the melting curve can be easily confirmed by switching tabs</p>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/lifescience/dnarna/tm_analysis_system/tm-aft_3_3.png" alt="measuring sample spectrum"/></figure>



<p></p>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/lifescience/dnarna/tm_analysis_system/down_arrow.png" alt="Arrow"/></figure>



<h3 class="wp-block-heading">Automate annealing with simple settings</h3>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/lifescience/dnarna/tm_analysis_system/tm-ft_3_4.png" alt="Automate annealing"/></figure>



<p>By raising and lowering the temperature of the sample, the nucleic acids are made single-stranded and then re-bonded to double-stranded. This reduces the number of binding mismatches, enabling stable analysis.</p>



<p><br>■&nbsp;Automated annealing with temperature program setting<br>■&nbsp;Automated flow reduces the risk of sample mix-ups during the transition between measurement and annealing.<br>■&nbsp;Automatic recording of annealing and temperature settings</p>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/lifescience/dnarna/tm_analysis_system/tm-ft_3_5.png" alt="Automate annealing"/></figure>



<p></p>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/lifescience/dnarna/tm_analysis_system/down_arrow.png" alt="Arrow"/></figure>



<h3 class="wp-block-heading">Easy setup and automatic Tm measurement and analysis</h3>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/lifescience/dnarna/tm_analysis_system/tm-ft_3_6.png" alt="Tm measurement"/></figure>



<p>It measures the change in absorbance during the melting process of nucleic acids from double strands to single strands as the temperature rises.<br>The Tm value (the melting temperature at which the mole fractions of double-stranded and single-stranded molecules are equal) is calculated by the average method, which determines a value based on the intersection of the melting curve and the median line of the tangents of the sections selected in the pre and post-transition region, or by the derivative method obtained from the maximum value of the first derivative.</p>



<p><br>■&nbsp;Tm analysis supports both average and derivative methods</p>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/lifescience/dnarna/tm_analysis_system/tm-ft_3_7.png" alt="Tm Analysis Settings"/></figure>



<p>■&nbsp;All application logs from measurement to analysis are automatically recorded to ensure reproducibility</p>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/lifescience/dnarna/tm_analysis_system/tm-ft_3_8.png" alt="Application log (LabSolutions DB)"/></figure>



<p>■&nbsp;Automatic calculation of Tm values enables analysis that eliminates the need for human intervention</p>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/lifescience/dnarna/tm_analysis_system/tm-ft_3_9.png" alt="tm analysis"/></figure>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/lifescience/dnarna/tm_analysis_system/down_arrow.png" alt="Arrow"/></figure>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/lifescience/dnarna/tm_analysis_system/tm_ana_sys_img16.png" alt="Example of Tm Analysis"/></figure>



<p>Example of Tm Analysis </p>



<figure class="wp-block-embed-youtube wp-block-embed is-type-video is-provider-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio"><div class="wp-block-embed__wrapper">
<iframe loading="lazy" title="How to Measure Melting Temperature using the Shimadzu TM Analysis System" width="696" height="392" src="https://www.youtube.com/embed/j-0VKmQepEE?feature=oembed&#038;enablejsapi=1" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe>
</div></figure>



<p> <strong>
<!--change the width and height value as you want.--> 
<!-- Do change "index.htm" to your real html name of the flippingbook--> 
<iframe  style="width:100%;height:450px"  src="https://www.barascientific.com/product/wp-content/uploads/flipbook/321/book.html"  seamless="seamless" scrolling="no" frameborder="0" allowtransparency="true" allowfullscreen mozallowfullscreen  webkitallowfullscreen ></iframe>
</strong> </p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.barascientific.com/product/tm-analysis-system-tm-analysis-system/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<media:content url="https://www.youtube.com/embed/j-0VKmQepEE" medium="video" width="1280" height="720">
			<media:player url="https://www.youtube.com/embed/j-0VKmQepEE" />
			<media:title type="plain">How to Measure Melting Temperature using the Shimadzu TM Analysis System</media:title>
			<media:description type="html"><![CDATA[How to Measure Melting Temperature using the TM Analysis SystemShimadzu’s new Tm Analysis system comprises of the UV-Vis spectrometer, the TMSPC8i temperatur...]]></media:description>
			<media:thumbnail url="https://www.barascientific.com/product/wp-content/uploads/2025/07/how-to-measure-melting-temperatu.jpg" />
			<media:rating scheme="urn:simple">nonadult</media:rating>
		</media:content>
	</item>
		<item>
		<title>AA-7800 &#8212; Atomic Absorption Spectrophotometer</title>
		<link>https://www.barascientific.com/product/aa-7800-atomic-absorption-spectrophotometer/</link>
					<comments>https://www.barascientific.com/product/aa-7800-atomic-absorption-spectrophotometer/#respond</comments>
		
		<dc:creator><![CDATA[Bara Scientific]]></dc:creator>
		<pubDate>Mon, 10 Jul 2023 11:38:00 +0000</pubDate>
				<category><![CDATA[AA]]></category>
		<guid isPermaLink="false">http://www.barascientific.com/product/?p=3396</guid>

					<description><![CDATA[Infinite Possibilities. The Shimadzu Atomic Absorption Spectrophotometer AA -7800 Series is versatile enough for a variety of analytical applications (Any Application), safe and easy to use even for beginners (Any User), and offers continuous analysis using autosamplers and remote data analysis via network connections to increase the flexibility of the analysis operator&#8217;s work style (Any [&#8230;]]]></description>
										<content:encoded><![CDATA[
<p><strong>Infinite Possibilities.</strong></p>



<p>The Shimadzu Atomic Absorption Spectrophotometer AA -7800 Series is versatile enough for a variety of analytical applications (Any Application), safe and easy to use even for beginners (Any User), and offers continuous analysis using autosamplers and remote data analysis via network connections to increase the flexibility of the analysis operator&#8217;s work style (Any Location).</p>



<h2 class="wp-block-heading">Any Application</h2>



<p>The AA-7800 Series can be upgraded by adding units to allow the system to handle the analysis targets.</p>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/2022-05/AA-7800/7800ft1_3.png" alt="Any Application"/></figure>



<h2 class="wp-block-heading">Selectable Manual or Automatic Dual Atomizer System</h2>



<p>Manual Dual Atomizer System&nbsp; &nbsp;<strong>-Model with Manual Atomizer Switching Offers Superior General Applicability-</strong></p>



<p>Adding a GFA-7800 graphite furnace atomizer to the AA-7800F system enables manual switching between flame and furnace units. Switching between units is extremely easy and does not require any tools.<br>The manual-switching model also enables changing the burner angle and using an atomic muffle, which can measure various samples.</p>



<ul class="wp-block-list"><li></li><li></li></ul>



<p>Automatic Dual Atomizer System&nbsp;&nbsp;<strong>-Model with Automatic Atomizer Switching Offers Excellent Operability and Speed</strong></p>



<ul class="wp-block-list"><li><br>By adding a GFA-7800 graphite furnace atomizer to the AA-7800F/AAC system, automatic and quick switching between flame and furnace modes becomes possible with software operation. There is no need to disconnect tubing or wiring either.<br>It is recommended for users to switch between flame and furnace frequently for routine analysis.</li><li></li></ul>



<h2 class="wp-block-heading">Automatically Switches Between Eight Hollow Cathode Lamps</h2>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/2022-05/AA-7800/ft1_4.jpg" alt="Automatically Switches Between Eight Hollow Cathode Lamps"/></figure>



<p>The AA-7800 lamp housing includes functionality for automatically switching between eight hollow cathode lamps installed in a turret and simultaneously illuminating any two of the lamps.<br>In combination with an ASC-7800 autosampler, it can measure multiple elements automatically.</p>



<h2 class="wp-block-heading">Flame Analysis Offers Superior General Applicability</h2>



<p>Analyzes High-Concentration Elements by Changing the Burner Angle</p>



<p>Elements present in high concentrations can be measured in the flame analysis mode by adjusting the burner angle to decrease absorbance. That enables measurement of up to about 20 times higher element concentrations, which helps minimize dilution errors and the effects of measurement element contamination from containers or reagents used.</p>



<p>Note: The automatic dual atomizer system, which is a combination of the model with AAC and the GFA-7800, cannot change the burner angle.</p>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/2022-05/AA-7800/ft1_3.png" alt="Flame Analysis Offers Superior General Applicability"/></figure>



<h2 class="wp-block-heading">Any User</h2>



<h2 class="wp-block-heading">Measurement Screen Layout Shows Measurement Status at a Glance</h2>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/2022-05/AA-7800/ft2_1.png" alt="Measurement Screen Layout Shows Measurement Status at a Glance"/></figure>



<h2 class="wp-block-heading">Functionality for Supporting Analytical Condition Development</h2>



<h3 class="wp-block-heading">Automatic Gas Flowrate Optimization</h3>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/2022-05/AA-7800/ft2_2_1.png" alt="Automatic Gas Flowrate Optimization"/></figure>



<p>The optimal flame gas flowrate value must be determined when using organic solvents or after changing the burner height. The AA-7800 performs that gas flowrate optimization process automatically.<br>It detects the gas flowrate that results in the highest sensitivity by measuring the change in the absorbance of blank and standard samples due to gas flowrate, displays the absorbance difference in the window, and then automatically sets the flowrate to that value.</p>



<h3 class="wp-block-heading">Automatic Burner Height Optimization (Models with AAC)</h3>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/2022-05/AA-7800/ft2_2_2.png" alt="Automatic Burner Height Optimization (Models with AAC)"/></figure>



<p>The absorption sensitivity of the flame analysis can vary depending on burner height. This is because the flame temperature can vary due to the burner height, sensitivity levels can vary due to different flame types, even for the same height, and the absorption sensitivity can also be influenced by components in the matrix. The AA-7800F/AAC automatically searches for the optimal setting by varying the burner height in 0.5 mm steps.</p>



<h3 class="wp-block-heading">Optimum Furnace Program Search</h3>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/2022-05/AA-7800/ft2_2_3.png" alt="Optimum Furnace Program Search"/></figure>



<p>This function can automatically perform the steps involved in measuring data as the graphite tube heating parameters are gradually varied and then plotting that data as a graph in the window. That enables the optimal atomization and ashing temperatures to be determined.</p>



<h2 class="wp-block-heading">Simple and Easy-to-Use Furnace System</h2>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/2022-05/AA-7800/ft2_3_2.png" alt="replacing the graphite tube is easy"/></figure>



<p><strong>Replacing the Graphite Tube is Easy</strong><br>Furnace measurements require replacing the graphite tube. Thanks to the simple furnace structure, even first-time users can replace the tube easily using a specialized positioning jig. It is also easy to differentiate between using different graphite tubes ideal for given measurement applications.</p>



<h2 class="wp-block-heading">GFA-TV Graphite Furnace Camera (Optional)</h2>



<p>The camera can be used to confirm the sample injection position or sample drying status, which is helpful when evaluating or optimizing the temperature program. The sharp image clearly shows the status inside the graphite tube.</p>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/2022-05/AA-7800/ft2_4_1.png" alt="GFA-TV Graphite Furnace Camera (Optional)"/></figure>



<h2 class="wp-block-heading">Safety Technology for Flame AA Systems</h2>



<p><strong>Automatic Flame Extinguishing Function by Vibration Detection Sensor</strong><br>A built-in sensor automatically extinguishes the flame when it detects vibration. That eliminates any worry in the event of an earthquake or other major shaking.</p>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/products/aa/aa7800/ft2_5_1_1.png" alt="Safety Technology for Flame AA Systems"/></figure>



<h2 class="wp-block-heading">Other Safety Functions</h2>



<ul class="wp-block-list"><li>&#8211; Multi-Mode Automatic Gas Leak Check Function<br>&#8211;&nbsp;Automatic Flame Ignition and Extinguishing<br>&#8211;&nbsp;Automatic Air-N2O Switching Mechanism with Acetylene Flowrate Monitor<br>&#8211;&nbsp;Acetylene Regulator Failure Detection Mechanism<br>&#8211;&nbsp;Flashback Prevention by Pressure Monitor<br>&#8211;&nbsp;Instantaneous Power Interruption Detection Mechanism and Safety System for Reigniting Flame</li><li>&#8211; Burner Misuse Prevention Mechanism<br>&#8211;&nbsp;Flame Retardant Materials Used<br>&#8211;&nbsp;Tubing Parts with High Durability and Joints with High Reliability Used<br>&#8211;&nbsp;Ignition Switches Designed for Safety<br>&#8211;&nbsp;Clear Window<br>&#8211;&nbsp;Automatic Gas Shutoff by Flame Monitor<br>&#8211;&nbsp;Drain Tank Level Monitor</li></ul>



<h2 class="wp-block-heading">Any Location</h2>



<h2 class="wp-block-heading">World’s Smallest Dual System</h2>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/2022-05/AA-7800/ft3_1.png" alt="AA-7800/AAC Dual Atomizer System Dimensions (Top surface) Note: The indicated size does not include the ASC-7800 unit."/></figure>



<p>AA-7800/AAC Dual Atomizer System Dimensions (Top surface)<br>Note: The indicated size does not include the ASC-7800 unit.</p>



<p>Despite being a dual atomizer, the unit is only 940 mm wide (including the power supply unit for the graphite furnace atomizer).</p>



<h2 class="wp-block-heading">Compact and Multifunctional Autosampler ASC-7800</h2>



<h3 class="wp-block-heading">The Same Autosampler can be Used for Both Flame and Furnace Measurements</h3>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/2022-05/AA-7800/ft3_2.png" alt="Compact and Multifunctional Autosampler ASC-7800"/></figure>



<p>A single autosampler can be used for both flame and furnace measurements. There is no need to prepare two autosamplers. The simple design allows for sliding the autosampler left or right.</p>



<h3 class="wp-block-heading">Space-Saving Design</h3>



<p>&nbsp;Connecting the autosampler directly to the main unit minimizes installation space and simplifies maintenance.</p>



<h2 class="wp-block-heading">LabSolutions<img src="https://s.w.org/images/core/emoji/16.0.1/72x72/2122.png" alt="™" class="wp-smiley" style="height: 1em; max-height: 1em;" /> CS Supports Laboratory Network Connectivity</h2>



<p>Adding a WizAArd Agent connection kit (optional) enables compliance with electronic recordkeeping and electronic signature regulations, such as requirements specified in FDA 21 CFR Part 11. Select either a standalone (LabSolutions DB) or networked (LabSolutions CS) system that is best for the given application.<br>LabSolutions CS manages all analytical data in a database on a network server, so that the data can be loaded and analyzed on any computer connected to the network.<br><br>Note: An additional software license is required for analyzing data onto a computer not connected to the AA system.</p>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/2022-05/AA-7800/ft3_3.png" alt="LabSolutions&#x2122; CS Supports Laboratory Network Connectivity"/></figure>



<figure class="wp-block-embed-youtube wp-block-embed is-type-video is-provider-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio"><div class="wp-block-embed__wrapper">
<iframe loading="lazy" title="AA-7800 Series - Atomic Absorption Spectrophotometers" width="696" height="392" src="https://www.youtube.com/embed/5Ley_uWhNZ4?feature=oembed&#038;enablejsapi=1" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe>
</div></figure>



<p> <strong>
<!--change the width and height value as you want.--> 
<!-- Do change "index.htm" to your real html name of the flippingbook--> 
<iframe  style="width:100%;height:450px"  src="https://www.barascientific.com/product/wp-content/uploads/flipbook/211/book.html"  seamless="seamless" scrolling="no" frameborder="0" allowtransparency="true" allowfullscreen mozallowfullscreen  webkitallowfullscreen ></iframe>
</strong> </p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.barascientific.com/product/aa-7800-atomic-absorption-spectrophotometer/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<media:content url="https://www.youtube.com/embed/5Ley_uWhNZ4" medium="video" width="1280" height="720">
			<media:player url="https://www.youtube.com/embed/5Ley_uWhNZ4" />
			<media:title type="plain">AA-7800 Series - Atomic Absorption Spectrophotometers</media:title>
			<media:description type="html"><![CDATA[The Shimadzu Atomic Absorption Spectrophotometer AA -7800 Series is versatile enough for a variety of analytical applications, safe and easy to use even for ...]]></media:description>
			<media:thumbnail url="https://www.barascientific.com/product/wp-content/uploads/2025/07/aa-7800-series-atomic-absorption.jpg" />
			<media:rating scheme="urn:simple">nonadult</media:rating>
		</media:content>
	</item>
		<item>
		<title>Lightway &#8211; PQY-01 Photoreaction Evaluation System</title>
		<link>https://www.barascientific.com/product/lightway-pqy-01-photoreaction-evaluation-system/</link>
					<comments>https://www.barascientific.com/product/lightway-pqy-01-photoreaction-evaluation-system/#respond</comments>
		
		<dc:creator><![CDATA[Bara Scientific]]></dc:creator>
		<pubDate>Sat, 13 May 2023 10:46:00 +0000</pubDate>
				<category><![CDATA[UV-VIS]]></category>
		<guid isPermaLink="false">http://www.barascientific.com/product/?p=3380</guid>

					<description><![CDATA[*The photoreaction evaluation system PQY-01 is the successor to the photoreaction quantum yield evaluation system QYM-01. This system can measure the number of photons absorbed, which is necessary for calculating the quantum yield of photoreactions. Photoreaction Quantum Yield: For a comparison to data obtained with the conventional method using a chemical actinometer, refer to LAAN-A-UV-E041 [&#8230;]]]></description>
										<content:encoded><![CDATA[
<p>*The photoreaction evaluation system PQY-01 is the successor to the photoreaction quantum yield evaluation system QYM-01.</p>



<p>This system can measure the number of photons absorbed, which is necessary for calculating the quantum yield of photoreactions.</p>



<h2 class="wp-block-heading">Photoreaction Quantum Yield:</h2>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/molecular_spectro/uv/lightway/img_photo.png" alt="Photoreaction quantum yield"/></figure>



<p>For a comparison to data obtained with the conventional method using a chemical actinometer, refer to LAAN-A-UV-E041 Application News&nbsp;bulletin No. A478.</p>



<ul class="wp-block-list"><li>Application News No. A478 &#8220;QYM-01 Photoreaction Quantum Yield Evaluation System&#8221;</li></ul>



<p>This photoreaction evaluation system was developed by Shimadzu Corporation, under the&nbsp;supervision of Professor Osamu Ishitani and Associate Professor Yusuke Tamaki of the Department&nbsp;of Chemistry, Graduate School of Science and Engineering, Tokyo Institute of Technology.<br>Analytical Intelligence logo, PQY and Lightway are trademarks of Shimadzu Corporation.</p>



<h2 class="wp-block-heading">Shortens Experimental Process</h2>



<figure class="wp-block-image"><a href="https://www.shimadzu.com/an/products/brand/analytical_intelligence.html" target="_blank" rel="noopener"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/molecular_spectro/uv/lightway/ana_inte_logo.png" alt="Analytical Intelligence"/></a></figure>



<p>Conventional measurement requires a lengthy process using a chemical&nbsp;actinometer but Lightway<sup><img src="https://s.w.org/images/core/emoji/16.0.1/72x72/2122.png" alt="™" class="wp-smiley" style="height: 1em; max-height: 1em;" /></sup>&nbsp;includes functionality that calibrates the&nbsp;number of irradiated photons, eliminating this process.</p>



<p>*Using a chemical actinometer involves sample adjustment process steps, such as crystallizing, air&nbsp;drying, and diluting samples, and then measuring the number of photons in a dark room and&nbsp;calibrating the number of photons irradiated on the sample.</p>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/molecular_spectro/uv/lightway/ft1_01.png" alt="Shortens Experimental Process"/></figure>



<h2 class="wp-block-heading">Measuring is Easy</h2>



<figure class="wp-block-image"><a href="https://www.shimadzu.com/an/products/brand/analytical_intelligence.html" target="_blank" rel="noopener"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/molecular_spectro/uv/lightway/ana_inte_logo.png" alt="Analytical Intelligence"/></a></figure>



<p>It can monitor spectral changes* during the photoreaction process in real time.<br>Measurements can be started by specifying mainly three parameter settings<br>(measurement interval, measurement time, and number of irradiated photons),<br>which makes it easy to operate even for first-time users. Also, a dialog box is<br>displayed whenever a button is pressed to help navigate operations.</p>



<p>* Results for specific wavelengths can be graphed as a function of time.</p>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/molecular_spectro/uv/lightway/ft2_01.jpg" alt="The PQY-Meas software"/></figure>



<p>Irradiated light settings<br><strong>LEDs provide stable, bright, and long-lasting irradiation light. That means reliable results can be obtained anytime.</strong>&nbsp;Also, experimental reproducibility can be increased by specifying the quantity of light irradiated.<br>&nbsp;</p>



<p>Time-course measurement results at a monitored wavelength<br><strong>Time-course changes in the absorbance at any particular wavelength can be determined&nbsp;instantaneously.</strong>&nbsp;By specifying the specic wavelength as&nbsp;the monitored wavelength before starting a&nbsp; measurement,&nbsp;spectral changes can be displayed as a function of time,&nbsp;so that the end of the reaction can be conrmed more&nbsp;quickly and the reaction rate can be conrmed more&nbsp;intuitively.</p>



<p>Measurement results for all spectra<br><strong>No bothersome settings are necessary.</strong>&nbsp;Only the&nbsp;measurement interval and measurement time need to be&nbsp;specied for spectra measurement conditions. The&nbsp;minimum measurement interval setting is 0.1 seconds.&nbsp;That means spectra from 250 to 800 nm can be acquired&nbsp;within 0.1 seconds to track reactions quickly.</p>



<h3 class="wp-block-heading">The PQY<sup><img src="https://s.w.org/images/core/emoji/16.0.1/72x72/2122.png" alt="™" class="wp-smiley" style="height: 1em; max-height: 1em;" /></sup>-Meas software that comes standard with the system offers the following three modes.</h3>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/molecular_spectro/uv/lightway/ft2_02.png" alt="Photoreaction Measurements"/></figure>



<h3 class="wp-block-heading">Photoreaction Measurements</h3>



<p>Measures a spectrum while the sample is irradiated by the irradiation light source.</p>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/molecular_spectro/uv/lightway/ft2_03.png" alt="Spectral Measurements"/></figure>



<h3 class="wp-block-heading">Spectral Measurements</h3>



<p>Measures a spectrum after the sample is irradiated by the irradiation light source. It can also perform regular spectral measurements&nbsp;as a spectrophotometer.</p>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/molecular_spectro/uv/lightway/ft2_04.png" alt="Calibration Curve &amp; Quantitation"/></figure>



<h3 class="wp-block-heading">Calibration Curve &amp; Quantitation</h3>



<p>Creates a calibration curve from a standard sample to determine concentrations in unknown samples.</p>



<h2 class="wp-block-heading">Measures Photon Count Accurately</h2>



<figure class="wp-block-image"><a href="https://www.shimadzu.com/an/products/brand/analytical_intelligence.html" target="_blank" rel="noopener"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/molecular_spectro/uv/lightway/ana_inte_logo.png" alt="Analytical Intelligence"/></a></figure>



<p>Previously, a chemical actinometer was required to calculate the number of irradiated photons,&nbsp;but there were concerns about variability caused by the chemical actinometer adjustment&nbsp;process. The Lightway<sup><img src="https://s.w.org/images/core/emoji/16.0.1/72x72/2122.png" alt="™" class="wp-smiley" style="height: 1em; max-height: 1em;" /></sup>&nbsp;system uses a power meter to calibrate the number of irradiated&nbsp;photons and make corrections based on spectral shape prior to measuring, which prevents&nbsp;variability caused by differences in skill levels.<br>&nbsp; &nbsp; It also features a stable and long-lasting LED irradiation light source.&nbsp;</p>



<h3 class="wp-block-heading">Using an LED irradiation light source means reliable measurements can be obtained&nbsp;over long periods.</h3>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/molecular_spectro/uv/lightway/ft3_01.png" alt="Measures Photon Count Accurately"/></figure>



<p>The figure above illustrates one example of how light source intensity decreases over time. The red line indicates the intensity of an&nbsp;LED irradiation light source, whereas the blue line indicates the&nbsp;intensity of a xenon lamp irradiation light source. It shows that the&nbsp;LED irradiation light source offers high intensity for a longer time and the intensity decrease is more gradual than for the xenon lamp&nbsp;irradiation light source.</p>



<h3 class="wp-block-heading">An optional LED irradiation light source is&nbsp;available.*</h3>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/molecular_spectro/uv/lightway/ft3_02.png" alt="An optional LED irradiation light source is available."/></figure>



<p>* This product is manufactured by CELL System Co., Ltd. Therefore,&nbsp;it must be purchased as an optional product.</p>



<h3 class="wp-block-heading">The LED irradiation light source can be&nbsp;replaced easily.</h3>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/molecular_spectro/uv/lightway/ft3_03.png" alt="The LED irradiation light source can be replaced easily."/></figure>



<p><br> <strong>
<!--change the width and height value as you want.--> 
<!-- Do change "index.htm" to your real html name of the flippingbook--> 
<iframe  style="width:100%;height:450px"  src="https://www.barascientific.com/product/wp-content/uploads/flipbook/280/book.html"  seamless="seamless" scrolling="no" frameborder="0" allowtransparency="true" allowfullscreen mozallowfullscreen  webkitallowfullscreen ></iframe>
</strong> </p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.barascientific.com/product/lightway-pqy-01-photoreaction-evaluation-system/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>LabSolutions IR &#8212; Analytical Data System for FTIR</title>
		<link>https://www.barascientific.com/product/labsolutions-ir-analytical-data-system-for-ftir/</link>
					<comments>https://www.barascientific.com/product/labsolutions-ir-analytical-data-system-for-ftir/#respond</comments>
		
		<dc:creator><![CDATA[Bara Scientific]]></dc:creator>
		<pubDate>Sun, 17 Jul 2022 06:44:00 +0000</pubDate>
				<category><![CDATA[FTIR]]></category>
		<guid isPermaLink="false">http://www.barascientific.com/product/?p=3415</guid>

					<description><![CDATA[Network-enabled as part of the LabSolutions family, LabSolutions IR is furnised with rich spectral libraries and a high-performance search functio as standard. Labor-saving macros provide for a higher level of automation and improved work efficiency. Network-Enabled As a part of the LabSolutions family of control software, LabSolutions IR provides advanced security and user administration features. [&#8230;]]]></description>
										<content:encoded><![CDATA[
<p> Network-enabled as part of the LabSolutions family, LabSolutions IR is furnised with rich spectral libraries and a high-performance search functio as standard. Labor-saving macros provide for a higher level of automation and improved work efficiency. </p>



<h2 class="wp-block-heading">Network-Enabled</h2>



<ul class="wp-block-list"><li>As a part of the LabSolutions family of control software, LabSolutions IR provides advanced security and user administration features.</li><li>Complies with ER/ES regulations including FDA 21 CFR Part 11 and PIC/S.</li><li>Centralized management of valuable FTIR data, as well as LC and GC data, on a networked server allows simple control over security and backups.</li></ul>



<p>Manage your valuable data from a centralized networked server. The LabSolutions IR Series enables networked management of FTIR as well as LC and GC data. In addition, it is capable of managing a wide variety of analytical instruments on a network.</p>



<h3 class="wp-block-heading">LabSolutions CS</h3>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/molecular_spectro/ftir/labsol/n9j25k000009k7rb-img/n9j25k000009l68b.jpg" alt=""/></figure>



<p>When connected without restrictions to an analytical network, LabSolutions CS manages all analytical data in a central database on a server computer, facilitating access to analytical data from any computer connected to that network.&nbsp;LabSolutions CS is ideal for customers wanting compliance with ER/ES regulations while seeking to manage LC/GC data together with FTIR data on one server hosting a large number of users.</p>



<h3 class="wp-block-heading">LabSolutions DB IR</h3>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/molecular_spectro/ftir/labsol/n9j25k000009k7rb-img/n9j25k000009l68l.gif" alt=""/></figure>



<p>LabSolutions DB IR combines analytical data management functions with LabSolutions IR and is capable of providing secure data management from a single computer. Compliant with FDA 21 CFR Part 11 and PIC/S, LabSolutions DB IR is the optimal setup for customers LabSolutions IR is a consolidation of the advanced features found in Shimadzu&#8217;s earlier IRsolution control software. In addition to improved operability, LabSolutions IR employs advanced management functions to provide a safe and highly reliable system solution. wanting to manage all their data from a single computer. It requires no network connection and is recommended for customers who seek ER/ES compliance in a standalone format.</p>



<h3 class="wp-block-heading">LabSolutions IR</h3>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/molecular_spectro/ftir/labsol/n9j25k000009k7rb-img/n9j25k000009l68v.gif" alt=""/></figure>



<p>LabSolutions IR is a consolidation of the advanced features found in Shimadzu&#8217;s earlier IRsolution control software. In addition to improved operability, LabSolutions IR employs advanced management functions to provide a safe and highly reliable system solution. wanting to manage all their data from a single computer. It requires no network connection and is recommended for customers who seek ER/ES compliance in a standalone format.&nbsp;</p>



<figure class="wp-block-table"><table class=""><tbody><tr><td>Name</td><td>LabSolutions IR</td><td>LabSolutions DB IR</td><td>LabSolutions CS</td></tr><tr><td>Data management method</td><td>Measured data files are saved and&nbsp; managed in folders on the PC.</td><td>Measured data files are saved and managed in the LabSolutions database.</td></tr><tr><td>Data references</td><td>The software references files on drives or in folders on the PC.</td><td>The software references files in the database.</td></tr><tr><td>LabSolutions database</td><td>Unavailable</td><td>Available<br>&nbsp;(The database resides on a local PC)</td><td>Available<br>&nbsp;(The database resides on a server)</td></tr><tr><td>User administration</td><td>Available</td></tr><tr><td>Rights group administration</td><td>Available</td></tr><tr><td>Project administration</td><td>Unavailable</td><td>Available</td></tr><tr><td>Standalone /network</td><td>Either can be used.</td><td>Only the standalone configuration<br>can be used.</td><td>Only databases on the network can be used.<br>LabSolutions IR data can be viewed using the database manager on a PC set up for viewing purposes. Note that LabSolutions IR must be installed on the PC used for viewing.</td></tr><tr><td>Data backup</td><td>Performed on a file-by-file basis using Windows Explorer.</td><td>Performed for each database.</td></tr></tbody></table></figure>



<h2 class="wp-block-heading">Rich Libraries and a High-Performance Search Function</h2>



<ul class="wp-block-list"><li>A library of approximately 12,000 spectra included as standard.</li><li>The standard library alone has enough data to furnish productive searching.</li><li>Advanced library search functions include spectral search, text search, compound search, and peak search.</li><li>Employing Shimadzu&#8217;s unique search algorithms for a high hit quality.</li></ul>



<h3 class="wp-block-heading">Approximately 12,000-spectra library</h3>



<p>A wide variety of libraries, including unique SHIMADZU libraries, reagents, polymers, and more are included as standard. Searching with standard libraries provides high-quality results without purchasing extra libraries.<br><br><strong>Contents</strong><br>· SHIMADZU Food additives library<br>· SHIMADZU Contaminants library<br>· Reagents<br>· Polymers<br>· Pharmaceutical products, agrichemicals<br>· Inorganic compounds, etc.<br>Total approx. 12,000 spectra</p>



<h3 class="wp-block-heading">High-performance search functions</h3>



<p>LabSolutions IR delivers high-quality of search results with 4 high-performance search methods (spectral search, peak search, text search and combination search) and libraries containing approximately 12,000 spectra. Libraries created on IRsolution and HYPER-IR and commercial libraries such as Sadtler and S.T. Japan can also be used. Simply drag spectra into a library to create a user library. Editing spectrum information or deleting a spectrum in a library is also very easy.<br><br><strong>Search functions</strong><br>・Spectral search<br>SHIMADZU’S unique search algorithm provide highly precise results.<br><br>・Peak search<br>If you only have an old spectrum chart, searching can be done with peak wavenumbers without a spectrum file.</p>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/molecular_spectro/ftir/labsol/n9j25k000009k7x0-img/n9j25k000009l69f.jpg" alt=""/></figure>



<h2 class="wp-block-heading">Macro Functions Provide Automation and Labor-Savings</h2>



<ul class="wp-block-list"><li>A simple macro function allows the user to execute multiple operations by simply creating a list of operational steps.</li><li>Contaminant analysis and identification tests are automatically done through use of macros for a more efficient workflow.</li></ul>



<p>LabSolutions IR automates routine work, such as scanning-data manipulation-reporting,identification tests, and contaminants analysis.Programs are launched from Launcher or your Desktop.</p>



<h3 class="wp-block-heading">Easy Macro – Just a single click launches routine work.</h3>



<p>The “Easy Macro” function will create macros that are suitable for routine work, particularly when repetitive operations are used. The macro builder allows macros to be constructed by simply selecting and aligning operations from a list. Once constructed, the macros can be registered with the Launcher and Desktop for quick execution. Operators not familiar with IR instruments can operate them easily without any mistakes.<br><br><strong>Easy Macro Operations</strong></p>



<ul class="wp-block-list"><li>Initialization of FTIR, configuration of scan parameters,spectrum measurement</li><li>Data manipulations, Search, Quantitation, Printing</li><li>Repeat measurements, Displaying messages, alarm sounds,External program execution</li></ul>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/molecular_spectro/ftir/labsol/n9j25k000009k82t-img/n9j25k000009l6a5.jpg" alt=""/></figure>



<h3 class="wp-block-heading">Making a Macro</h3>



<figure><iframe loading="lazy" allowfullscreen="" height="400" src="https://www.youtube.com/embed/9X-e8tevkfg?rel=0&amp;enablejsapi=1&amp;origin=https%3A%2F%2Fwww.shimadzu.com" width="512"></iframe></figure>



<h2 class="wp-block-heading">Contaminant analysis/Identification test program</h2>



<p>LabSolutions IR includes two main application programs &#8211; Contaminant analysis/Identification test program &#8211; for contaminant analysis and identification tests.</p>



<h2 class="wp-block-heading">Contaminant analysis program</h2>



<p>By combining SHIMADZU’s own algorithms (patent pending) with that of library spectra for common contaminants, this program identifies contaminants with a high degree of accuracy. Reports are automatically created after analysis, thereby reducing post-processing time to a few seconds. With automated reporting, this easy-to-use program allows operators with little FTIR knowledge to perform analysis easily.<br><br><strong>4 features of the Contaminant analysis program</strong></p>



<ul class="wp-block-list"><li>Contains spectra for over 500 highly-selected inorganic substances, organic substances, and polymers that are often detected as contaminants in SHIMADZU’s Analytical Applications Department.</li><li>Allows automation of the process, including searching,judgment evaluation, and report creation.</li><li>Incorporates algorithms that focus on spectral characteristics,rather than performing simple spectrum searches.</li><li>Major and Minor components are found and their ranks are displayed.</li></ul>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/molecular_spectro/ftir/labsol/n9j25k000009k88e-img/n9j25k000009l6cm.jpg" alt=""/></figure>



<h2 class="wp-block-heading">Identification test program</h2>



<p>This program makes pass/fail judgments about samples in accordance with the tests specified in the Pharmacopoeia. In addition to identification tests for pharmaceutical products, this program can be used for incoming inspections and pre-shipment inspections.<br><br><strong>4 features of the Identification test program</strong></p>



<ul class="wp-block-list"><li>Prints out the spectra for standards and samples in order to facilitate easy comparison.</li><li>Calculation of the differences between the peak wavenumbers for standards and samples, differences in intensity ratios between peaks, pass/fail judgments, and print out of reports.</li><li>Detection and printing just the peaks that are specified for pass/fail judgment.</li><li>Spectra of 57 samples on Japanese Standards of Food Additives are stored in LabSolutions IR.</li></ul>



<figure class="wp-block-image"><img decoding="async" src="https://www.shimadzu.com/an/sites/shimadzu.com.an/files/d7/ckeditor/an/molecular_spectro/ftir/labsol/n9j25k000009k88e-img/n9j25k00000d9s4c.jpg" alt=""/></figure>



<p> <strong>
<!--change the width and height value as you want.--> 
<!-- Do change "index.htm" to your real html name of the flippingbook--> 
<iframe  style="width:100%;height:450px"  src="https://www.barascientific.com/product/wp-content/uploads/flipbook/271/book.html"  seamless="seamless" scrolling="no" frameborder="0" allowtransparency="true" allowfullscreen mozallowfullscreen  webkitallowfullscreen ></iframe>
</strong> </p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.barascientific.com/product/labsolutions-ir-analytical-data-system-for-ftir/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<media:content url="https://www.youtube.com/embed/9X-e8tevkfg" medium="video" width="1280" height="720">
			<media:player url="https://www.youtube.com/embed/9X-e8tevkfg" />
			<media:title type="plain">LabSolutions IR Video - Making a Macro</media:title>
			<media:description type="html"><![CDATA[This video is about how to build a macro using the “EasyMacro” module on LabSolutions IR software. Basic components of a macro are discussed. A simple macro ...]]></media:description>
			<media:thumbnail url="https://www.barascientific.com/product/wp-content/uploads/2025/07/labsolutions-ir-video-making-a-m.jpg" />
			<media:rating scheme="urn:simple">nonadult</media:rating>
		</media:content>
	</item>
	</channel>
</rss>
