<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	xmlns:media="http://search.yahoo.com/mrss/" >

<channel>
	<title>AXIMA &#8211; Product</title>
	<atom:link href="https://www.barascientific.com/product/category/analytical-instruments/life-science-lab-instruments/axima/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.barascientific.com/product</link>
	<description>Solution of Success</description>
	<lastBuildDate>Fri, 11 Jul 2025 07:18:04 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8.3</generator>
	<item>
		<title>AXIMA Performance &#8212; MALDI TOF-TOF Mass Spectrometer</title>
		<link>https://www.barascientific.com/product/axima-performance-maldi-tof-tof-mass-spectrometer/</link>
					<comments>https://www.barascientific.com/product/axima-performance-maldi-tof-tof-mass-spectrometer/#respond</comments>
		
		<dc:creator><![CDATA[Bara Scientific]]></dc:creator>
		<pubDate>Sun, 06 Sep 2020 07:33:00 +0000</pubDate>
				<category><![CDATA[AXIMA]]></category>
		<category><![CDATA[AXIMA Performance]]></category>
		<guid isPermaLink="false">http://www.barascientific.com/product/?p=1865</guid>

					<description><![CDATA[A highly flexible research grade MALDI TOF/TOF mass spectrometer The AXIMA Performance is one of the most powerful tools in mass spectrometry, delivering information-rich spectra with greater sensitivity and&#160;higher confidence in identification. It is an extremely versatile and powerful TOF-TOF system, integrating workflows for a diverse range of analytical needs. From high energy MS/MS of [&#8230;]]]></description>
										<content:encoded><![CDATA[<h2 class="heading-02">A highly flexible research grade MALDI TOF/TOF mass spectrometer</h2>
<p>The AXIMA Performance is one of the most powerful tools in mass spectrometry, delivering information-rich spectra with greater sensitivity and&nbsp;<strong>higher confidence in identification</strong>. It is an extremely versatile and powerful TOF-TOF system, integrating workflows for a diverse range of analytical needs.</p>
<ul>
<li>From high energy MS/MS of proteomics and other biological and organic samples to uncompromised analysis of high mass intact proteins</li>
<li>True high energy MS/MS &#8211; CID with a laboratory frame collision energy of 20keV</li>
<li>Optimal precursor ion selection resolution using revolutionary gating technology</li>
<li>Outstanding sensitivity &#8211; uncompromised design, to ensure no MS/MS signal is discarded</li>
</ul>


<h2 class="wp-block-heading"><strong>Features</strong></h2>



<h2 class="wp-block-heading">Can be used in various research fields</h2>



<p>A diverse range of applications are supported, including fully automated proteomics experiments, LC MALDI analyses, functional genomics, quality control and polymer interrogation.</p>



<h3 class="wp-block-heading">Proteomics suite</h3>



<ul class="wp-block-list"><li>Designed with the flexibility to adapt to users&#8217; workflow: from single sample manual acquisition to fully automated data-dependent peptide mass fingerprinting and MS/MS for protein identification.</li><li>Peptide mass fingerprints are acquired and subjected to an optional integrated Mascot® database search.</li><li>User defined acceptance limits for PMF-based protein identification.</li><li>Data-dependent MS/MS: using the results of the PMF search, MS/MS may be performed on ions that matched to the top ranked protein hit (confirmation MS/MS), in addition to those that were not (investigation MS/MS). Batch searching of these MS/MS spectra is then performed automatically to provide further and higher confidence protein identification.</li><li>Data may be reprocessed and resubmitted for database searching at a later time to provide additional information.</li></ul>



<h3 class="wp-block-heading">LC MALDI integrated package</h3>



<ul class="wp-block-list"><li>The AXIMA Performance provides total support for LC-MALDI based experiments.</li><li>The software suite allows the fully automated acquisition of LC separated samples deposited onto MALDI targets and the subsequent identification of proteins via MS/MS of the peptides detected.</li><li>Automatically provides a provisional intensity map of all sample spots across the target to assess the distribution of peptides and identify the position of the apex of the chromatographic peaks. These are utilized to generate a candidate list and MS/MS data acquired for all discrete peptide ions.</li><li>Exclusion lists are used to remove known contaminants or high abundance peptides.</li><li>All data is subjected to an integrated Mascot® search.</li><li>Low sample consumption allows multiple spectra to be acquired from the same spot increasing the amount of MS/MS data obtained.</li></ul>



<h3 class="wp-block-heading">Biomarker Recognition/Tissue Imaging</h3>



<ul class="wp-block-list"><li>Seamless export of sample location to the Axima<img src="https://s.w.org/images/core/emoji/16.0.1/72x72/2122.png" alt="™" class="wp-smiley" style="height: 1em; max-height: 1em;" /> MALDI mass spectrometer</li><li>Automated acquisition of MS data &#8211; profiling or imaging</li><li>Visualization of the spatial distribution of components of interest via intensity mapping software</li><li>Easy export of data to alternative processing packages, including BioMAP</li></ul>



<h2 class="wp-block-heading">Other features</h2>



<h3 class="wp-block-heading">Essential features providing confident results</h3>



<ul class="wp-block-list"><li>High resolution MS data in reflectron mode for more accurate and confident peptide mass fingerprinting (PMF) and complex mixture analysis.</li><li>Uncompromised linear mass range and sensitivity.</li><li>Near-axis laser irradiation for enhanced ion transmission and sensitivity in all modes of operation.</li><li>Advanced calibration algorithms with easy to use software providing more accurate data.</li><li>Intuitive software incorporating data dependent workflows for achieving the maximum result with the minimum user input, making it ideal for novice and expert users alike.</li><li>Flexibility &#8211; this is not just another proteomics workhorse. Polymers, oligonucleotides, SNPs, metabolites, carbohydrates and small molecules amongst others may all be analysed and processed.</li></ul>



<h3 class="wp-block-heading">Key Performance Features</h3>



<ul class="wp-block-list"><li>Near-axis laser irradiation with a 50Hz variable repetition rate N2 laser</li><li>Uncompromised linear mode performance for high mass analysis</li><li>Patented improved curved field reflectron</li><li>Mass range 1-500kDa in linear mode; 1-80kDa in reflectron mode</li><li>Mass resolution 5000 FWHM (ACTH 18-39) in linear mode; 20000 FWHM (ACTH 7-38) in reflectron mode</li><li>Sensitivity 250 amol (Glu-fibrinopeptide) in reflectron mode</li><li>Mass accuracy &lt;5ppm in reflectron mode</li><li>Precursor ion resolution &gt;400 FWHM</li><li>High energy MS/MS using helium collision gas</li><li>Flexible target formats &#8211; ranging from 48 well microscope slide format targets to 384 well microtitre plate targets</li></ul>



<h3 class="wp-block-heading">Additional Key Features and Benefits</h3>



<ul class="wp-block-list"><li>Proteomics experiments</li><li>LC MALDI</li><li>Tissue imaging/biomarker discovery</li><li>Polymer analysis</li><li>Oligonucleotide/primer analysis</li><li>Full integration with robotic sample preparation devices such as the Accuspot and ChIP for a variety of applications</li></ul>



<p> <strong>
<!--change the width and height value as you want.--> 
<!-- Do change "index.htm" to your real html name of the flippingbook--> 
<iframe  style="width:100%;height:450px"  src="https://www.barascientific.com/product/wp-content/uploads/flipbook/218/book.html"  seamless="seamless" scrolling="no" frameborder="0" allowtransparency="true" allowfullscreen mozallowfullscreen  webkitallowfullscreen ></iframe>
</strong> </p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.barascientific.com/product/axima-performance-maldi-tof-tof-mass-spectrometer/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>AXIMA Confidence &#8212; MALDI TOF-TOF Mass Spectrometer</title>
		<link>https://www.barascientific.com/product/axima-confidence-maldi-tof-tof-mass-spectrometer/</link>
					<comments>https://www.barascientific.com/product/axima-confidence-maldi-tof-tof-mass-spectrometer/#respond</comments>
		
		<dc:creator><![CDATA[Bara Scientific]]></dc:creator>
		<pubDate>Sun, 06 Sep 2020 07:30:00 +0000</pubDate>
				<category><![CDATA[AXIMA]]></category>
		<category><![CDATA[AXIMA Confidence]]></category>
		<guid isPermaLink="false">http://www.barascientific.com/product/?p=1862</guid>

					<description><![CDATA[Taking MALDI-TOF MS Beyond the Standard Powerful MALDI-TOF performance for reliable mass information and MS/MS derived structural detail. Linear mode allows the interrogation of high molecular weight samples, whilst reflectron mode, incorporating the patented curved-field reflectron (CFR), provides the high resolution and mass accuracy necessary for successful proteomics and life science experiments. High sensitivity system [&#8230;]]]></description>
										<content:encoded><![CDATA[<h2 class="heading-02 u-noMargin--top">Taking MALDI-TOF MS Beyond the Standard</h2>
<ul class="list-with-hyphen">
<li>Powerful MALDI-TOF performance for reliable mass information and MS/MS derived structural detail.</li>
<li>Linear mode allows the interrogation of high molecular weight samples, whilst reflectron mode, incorporating the patented curved-field reflectron (CFR), provides the high resolution and mass accuracy necessary for successful proteomics and life science experiments.</li>
<li>High sensitivity system using a variable repetition rate 50 Hz N2 laser and a variety of target formats to meet all sample throughput requirements.</li>
<li>An affordable robust option for all laboratories requiring routine manual or automated analysis of a wide variety of sample classes.</li>
<li>Excellent sensitivity is achieved using near-axis laser irradiation and advanced ion optics for enhanced ion transmission.</li>
<li>MS/MS may be easily performed using a seamless approach – ions of interest can be isolated using a precursor ion selection device, incorporated as standard, and data-rich fragment ion spectra quickly and simply acquired.The newly improved curved field reflectron design augments the low mass fragment region providing useful additional information.</li>
</ul>


<h2 class="wp-block-heading"><strong>Features</strong></h2>



<h2 class="wp-block-heading">Key Performance Features</h2>



<ul class="wp-block-list"><li>Near-axis laser irradiation with a 50Hz variable repetition rate N2 laser</li><li>Patented improved curved field reflectron</li><li>Mass range 1-500kDa in linear mode; 1-80kDa in reflectron mode</li><li>Mass resolution 5000 FWHM (ACTH 18-39) in linear mode; 15000 FWHM (ACTH 7-38) in reflectron mode</li><li>Sensitivity 500 amol (Glu-fibrinopeptide) in reflectron mode</li><li>Mass accuracy &lt;10ppm in reflectron mode with internal calibration</li><li>Precursor ion resolution &gt;200 FWHM</li><li>Seamless MS/MS utilising PSD</li><li>Flexible target formats &#8211; ranging from 48 well microscope slide format targets to 384 well microtitre plate targets</li></ul>



<h2 class="wp-block-heading">Key Benefits</h2>



<ul class="wp-block-list"><li>Proteomics experiments</li><li>LC MALDI</li><li>Polymer analysis</li><li>Tissue imaging/biomarker discovery</li><li>Oligonucleotide/primer analysis</li><li>Full integration with robotic sample preparation devices such as the Accuspot and ChIP for a variety of applications</li></ul>



<p> <strong>
<!--change the width and height value as you want.--> 
<!-- Do change "index.htm" to your real html name of the flippingbook--> 
<iframe  style="width:100%;height:450px"  src="https://www.barascientific.com/product/wp-content/uploads/flipbook/217/book.html"  seamless="seamless" scrolling="no" frameborder="0" allowtransparency="true" allowfullscreen mozallowfullscreen  webkitallowfullscreen ></iframe>
</strong> </p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.barascientific.com/product/axima-confidence-maldi-tof-tof-mass-spectrometer/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>AXIMA Assurance &#8212; MALDI TOF-TOF Mass Spectrometer</title>
		<link>https://www.barascientific.com/product/axima-assurance-maldi-tof-tof-mass-spectrometer/</link>
					<comments>https://www.barascientific.com/product/axima-assurance-maldi-tof-tof-mass-spectrometer/#respond</comments>
		
		<dc:creator><![CDATA[Bara Scientific]]></dc:creator>
		<pubDate>Sun, 06 Sep 2020 07:20:00 +0000</pubDate>
				<category><![CDATA[AXIMA]]></category>
		<category><![CDATA[AXIMA Assurance]]></category>
		<guid isPermaLink="false">http://www.barascientific.com/product/?p=1859</guid>

					<description><![CDATA[High Performance Mass Detection Linear MALDI-TOF mass spectrometry for reliable mass information. An affordable, robust option for all laboratories requiring routine manual or automated analysis of a wide variety of sample classes. High sensitivity system using a variable repetition rate 50 Hz N2 laser and a variety of target formats to meet all sample throughput [&#8230;]]]></description>
										<content:encoded><![CDATA[
<h2 class="wp-block-heading">High Performance Mass Detection</h2>



<ul class="wp-block-list"><li>Linear MALDI-TOF mass spectrometry for reliable mass information.</li><li>An affordable, robust option for all laboratories requiring routine manual or automated analysis of a wide variety of sample classes.</li><li>High sensitivity system using a variable repetition rate 50 Hz N2 laser and a variety of target formats to meet all sample throughput requirements.</li></ul>



<h2 class="wp-block-heading"><strong>Features</strong></h2>



<h2 class="wp-block-heading">Key Performance Features</h2>



<h3 class="wp-block-heading">High Performance Mass Detection</h3>



<ul class="wp-block-list"><li>Near-axis laser irradiation with a 50Hz variable repetition rate N2 laser</li><li>Positive and negative ion modes as standard</li><li>Ion gate – used as beam blanker to remove unwanted low mass ions</li><li>Mass resolution &gt;5000 FWHM</li><li>Sensitivity – 250 amol Glu-fibrinopeptide</li><li>Mass accuracy &lt; 30ppm</li><li>Mass range 1–500kDa</li><li>Flexible target formats &#8211; ranging from 48 well microscope slide format targets to 384 well microtitre plate targets</li></ul>



<h2 class="wp-block-heading">Find out more of the key features and benefits</h2>



<h3 class="wp-block-heading">Ideally suited for high throughput QA/QC application areas, for example</h3>



<ul class="wp-block-list"><li>Oligonucleotides/primers</li><li>Synthetic peptides/proteins</li><li>Polymer analysis</li><li>Small molecules</li></ul>



<h3 class="wp-block-heading">Application areas include</h3>



<ul class="wp-block-list"><li>Protein profiling</li><li>Tissue imaging</li><li>Biomarker discovery</li><li>Single nucleotide polymorphisms</li></ul>



<h2 class="wp-block-heading">Find out more of the key features and benefits</h2>



<h3 class="wp-block-heading">Ideally suited for high throughput QA/QC application areas, for example</h3>



<ul class="wp-block-list"><li>Oligonucleotides/primers</li><li>Synthetic peptides/proteins</li><li>Polymer analysis</li><li>Small molecules</li></ul>



<h3 class="wp-block-heading">Application areas include</h3>



<ul class="wp-block-list"><li>Protein profiling</li><li>Tissue imaging</li><li>Biomarker discovery</li><li>Single nucleotide polymorphisms</li></ul>



<p> <strong>
<!--change the width and height value as you want.--> 
<!-- Do change "index.htm" to your real html name of the flippingbook--> 
<iframe  style="width:100%;height:450px"  src="https://www.barascientific.com/product/wp-content/uploads/flipbook/216/book.html"  seamless="seamless" scrolling="no" frameborder="0" allowtransparency="true" allowfullscreen mozallowfullscreen  webkitallowfullscreen ></iframe>
</strong> </p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.barascientific.com/product/axima-assurance-maldi-tof-tof-mass-spectrometer/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
