<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	xmlns:media="http://search.yahoo.com/mrss/" >

<channel>
	<title>Gas Chromatography &#8211; General Products</title>
	<atom:link href="https://www.barascientific.com/general/category/gl-sciences/gas-chromatography/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.barascientific.com/general</link>
	<description></description>
	<lastBuildDate>Wed, 02 Jul 2025 10:05:04 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8.2</generator>
	<item>
		<title>GL SCIENCES &#8211; GC packed columns</title>
		<link>https://www.barascientific.com/general/gl-sciences-gc-packed-columns/</link>
					<comments>https://www.barascientific.com/general/gl-sciences-gc-packed-columns/#respond</comments>
		
		<dc:creator><![CDATA[BSC]]></dc:creator>
		<pubDate>Thu, 25 Apr 2024 08:57:00 +0000</pubDate>
				<category><![CDATA[Gas Chromatography]]></category>
		<category><![CDATA[GL Sciences]]></category>
		<guid isPermaLink="false">https://www.barascientific.com/general/?p=1718</guid>

					<description><![CDATA[GC packed columns and capillary columns GL Sciences GC Columns are designed and manufactured in Japan and offer the lowest bleed levels, the best inertness for acids/bases/mixed functional compounds, and the tightest column-to-column reproducibility. We supply both capillary columns from very standard till very exclusive versions. Packed columns for gas chromatography are also produced in [&#8230;]]]></description>
										<content:encoded><![CDATA[<div class="wp-block-image">
<figure class="alignleft"><img decoding="async" src="https://www.glsciences.eu/gc-columns/gc-columns.jpg" alt="GC Columns"/></figure></div>


<figure class="wp-block-image"><img decoding="async" src="https://www.glsciences.eu/pictures/made-in-japan.jpg" alt=""/></figure>



<h2 class="wp-block-heading">GC packed columns and capillary columns</h2>



<p>GL Sciences GC Columns are designed and manufactured in Japan and offer the lowest bleed levels, the best inertness for acids/bases/mixed functional compounds, and the tightest column-to-column reproducibility.</p>



<p>We supply both capillary columns from very standard till very exclusive versions. Packed columns for gas chromatography are also produced in Japan, we have both Glass and SUS versions with many different packings.</p>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<p>Available capillary columns:1MS, 1, 1HT, 5MS/Sil, 5MS, 5, Pesticides, 624, 1301, 25, 35, 1701, 17MS, 17, 210, 225, Pure-WAX, WAX, WAX-HT, FFAP and fast GC Columns.</p>



<p>Special Columns: Amines, CHIRAMIX, AQUATIC, AQUATIC-2, Pesticides</p>



<p>Other Columns: Tailor made columns. Columns with build-in Guard Column or Transfer Line and also both.</p>



<figure class="wp-block-image"><img decoding="async" src="https://www.glsciences.eu/pictures/guard_column.png" alt="pre column"/></figure>



<p>Visit our&nbsp;<a href="https://glsciences.mamutweb.com/Shop/List/22-GC-Columns/79/1" target="_blank" rel="noreferrer noopener">webshop</a>&nbsp;for partnumbers and prices.</p>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<p>Available packed columns:We can supply both glass and metal packed columns produced by our factory in Japan. There are so many different versions available, please contact us and give us information about your GC model, liquid phase, phase loading, on what support material, support mesh size, column material, column dimensions and aging or not.</p>



<figure class="wp-block-image"><img decoding="async" src="https://www.glsciences.eu/gc-columns/packed-gc-column_ordering_guide.png" alt="select your packed gc column"/></figure>
]]></content:encoded>
					
					<wfw:commentRss>https://www.barascientific.com/general/gl-sciences-gc-packed-columns/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>GL SCIENCES &#8211; PHASER Pro</title>
		<link>https://www.barascientific.com/general/gl-sciences-phaser-pro/</link>
					<comments>https://www.barascientific.com/general/gl-sciences-phaser-pro/#respond</comments>
		
		<dc:creator><![CDATA[BSC]]></dc:creator>
		<pubDate>Wed, 10 Apr 2024 11:07:05 +0000</pubDate>
				<category><![CDATA[Gas Chromatography]]></category>
		<category><![CDATA[GL Sciences]]></category>
		<guid isPermaLink="false">https://www.barascientific.com/general/?p=1659</guid>

					<description><![CDATA[GL SCIENCES &#8211; PHASER Pro GC Olfactory Detection Port for GC or GC-MS The human nose is an incredible detector for aroma/mal-odour components. Gas Chromatography Olfactometry (GC-O) is a bioassay that measures human response to odorants separated by gas chromatography. The superior sensitivity and selectivity of human olfaction make GC-O a powerful and meaningful tool for [&#8230;]]]></description>
										<content:encoded><![CDATA[
<h2 class="wp-block-heading"><strong>GL SCIENCES &#8211; PHASER Pro GC Olfactory Detection Port for GC or GC-MS</strong></h2>



<div class="wp-block-media-text is-stacked-on-mobile" style="grid-template-columns:31% auto"><figure class="wp-block-media-text__media"><img fetchpriority="high" decoding="async" width="368" height="344" src="https://www.barascientific.com/general/wp-content/uploads/2024/04/PHASER-Pro-image.jpg" alt="" class="wp-image-1690 size-full" srcset="https://www.barascientific.com/general/wp-content/uploads/2024/04/PHASER-Pro-image.jpg 368w, https://www.barascientific.com/general/wp-content/uploads/2024/04/PHASER-Pro-image-300x280.jpg 300w, https://www.barascientific.com/general/wp-content/uploads/2024/04/PHASER-Pro-image-150x140.jpg 150w" sizes="(max-width: 368px) 100vw, 368px" /></figure><div class="wp-block-media-text__content">
<p>The human nose is an incredible detector for aroma/mal-odour components. Gas Chromatography Olfactometry (GC-O) is a bioassay that measures human response to odorants separated by gas chromatography.</p>



<p>The superior sensitivity and selectivity of human olfaction make GC-O a powerful and meaningful tool for flavour chemistry. Head-space sampling, distillation, solvent extraction, solid phase micro extraction (SPME) and our DMI are typical procedures used to introduce samples in a GC-O. Besides providing data about the potency of odorants extracted and separated for samples, GC-O can also be used to study variation in human olfaction or provide testing and training of panellists used in sensory testing. At its best, GC-O, provides industry with a link between chemical data collected from ingredients or products and the sensory and consumer preference data collected from the market place. At the very least GC-O data derived from a product can be used for quality control or the development of value added products.</p>
</div></div>



<p><strong>The PHASER Pro GC-O or GC Olfactometry</strong></p>



<p>The PHASER Pro is the latest edition of the sniffing port. A temperature-programmable transfer line is introduced in this instrument, that can be programmed as the GC oven. This results in a stable split ratio (sniffing flow rate/detector flow rate). Heat stress at the nose and thermal degradation of the compounds are prevented, making it possible to perform olfactory detection with higher accuracy and sensitivity.<br><br>The transfer line has been designed in such a way that there are no cold spots along the line. This allows high precision evaluation of odors. High-boiling or adsorptive compounds are not trapped inside the transfer line. The target compounds are obtained without loss.</p>



<ul class="wp-block-list">
<li>No cold spot gives the possibility to sniff the high boiling compounds.</li>



<li>Transfer line is hot till the end</li>



<li>Transfer line can be programmed in temperature</li>



<li>Maximum 300°C on the transfer line.</li>



<li>Protects your nose from drying by adding moist air to sniffing port.</li>



<li>Easy to connect the capillary column to the splitter.</li>



<li>Sitting down or standing up while sniffing.</li>



<li>Compact and easy to install on any GC instrument.</li>



<li>SplitManager software standard supplied.</li>



<li>Voice recording&nbsp;with replay function.</li>
</ul>



<p>The PHASER is standard supplied with all capillaries, 4 port microchannel connector, nuts and ferrules and SplitManager software in order to make the installation. Only a GC mounting plate kit is needed.</p>



<p><strong>Part Numbers:</strong><br>2702-18607 PHASER Pro GC Olfactory Port with SilFlow Splitter, 1000 mm TL<br>2702-18606 PHASER Pro Voicegram Interface Kit</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.barascientific.com/general/gl-sciences-phaser-pro/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>GL SCIENCES &#8211; CryoFocus</title>
		<link>https://www.barascientific.com/general/gl-sciences-cryofocus/</link>
					<comments>https://www.barascientific.com/general/gl-sciences-cryofocus/#respond</comments>
		
		<dc:creator><![CDATA[BSC]]></dc:creator>
		<pubDate>Wed, 10 Apr 2024 11:06:47 +0000</pubDate>
				<category><![CDATA[Gas Chromatography]]></category>
		<category><![CDATA[GL Sciences]]></category>
		<guid isPermaLink="false">https://www.barascientific.com/general/?p=1662</guid>

					<description><![CDATA[Cryogenic cold trapping is frequently used for narrowing the chromatographic band and improving the detection limit in Gas Chromatography. The cryotrap uses LN2 or CO2 for cooling, due to our low thermal mass the cooling is really fast. The CryoFocus has direct heating of the cooling chamber, resulting in amazingly fast heating of the trap. [&#8230;]]]></description>
										<content:encoded><![CDATA[
<div class="wp-block-media-text is-stacked-on-mobile" style="grid-template-columns:31% auto"><figure class="wp-block-media-text__media"><img decoding="async" width="294" height="337" src="https://www.barascientific.com/general/wp-content/uploads/2024/04/CryoFocus-image.jpg" alt="" class="wp-image-1687 size-full" srcset="https://www.barascientific.com/general/wp-content/uploads/2024/04/CryoFocus-image.jpg 294w, https://www.barascientific.com/general/wp-content/uploads/2024/04/CryoFocus-image-262x300.jpg 262w, https://www.barascientific.com/general/wp-content/uploads/2024/04/CryoFocus-image-150x172.jpg 150w" sizes="(max-width: 294px) 100vw, 294px" /></figure><div class="wp-block-media-text__content">
<p>Cryogenic cold trapping is frequently used for narrowing the chromatographic band and improving the detection limit in Gas Chromatography. The cryotrap uses LN2 or CO2 for cooling, due to our low thermal mass the cooling is really fast. The CryoFocus has direct heating of the cooling chamber, resulting in amazingly fast heating of the trap. After trapping the analytes must be released from the cryotrap using a highly accurate and extremely fast heating ensuring that they are introduced onto the column in a very sharp band. With a fast-heating cryo-trap better detection limit and better resolution can be seen on the detector.<br><br>Lately we have developed a new LN2 valve. Our in house developed LN2 valve is Silent and gives a better regulation of the low temperature.</p>
</div></div>



<h2 class="wp-block-heading">Increase in Sensitivity with our cryotrap the CryoFocus</h2>



<p>With CryoFocus-4 (Stand alone or integrated in OPTIC-4) analytes are focused at the head of the column by cooling its selected section to sub-ambient temperature. After re-focusing, the analytes are released from the GC cryotrap in a very narrow band using an extreme fast heating rate of 60 °C/second. As a result, very sharp peaks with a high signal to noise ratio are obtained.</p>



<figure class="wp-block-table"><table><tbody><tr><td><img decoding="async" src="https://www.glsciences.eu/base/leeg.gif" alt="leeg cryotrap" width="100" height="220"><a href="https://www.glsciences.eu/cryotrap/cold-trap.jpg" rel="noopener"></a>&nbsp;<img decoding="async" src="https://www.glsciences.eu/base/leeg.gif" alt="leeg cryotrap" width="100" height="220"></td><td>Can be used on any GC or GCMSStand alone or integrated in OPTIC-4Operating using direct LN<sub>2</sub> or CO<sub>2</sub>New from January 2023 is our silent LN2 valveTemperature range:  -150 °C to 350 °CTemperature stability at low temperature:  ±3 °CHeating ramp rate: 1 to 60 °C/secCool down time:  2-3 minutesCompatible with any GCSoftware controlled by Evolution WorkstationSoftware compatible with Chronos MastersoftwareFree software updates</td></tr></tbody></table></figure>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<figure class="wp-block-image"><img decoding="async" src="https://www.glsciences.eu/cryotrap/vinylchloride.jpg" alt="Vinylchloride with headspace better with a gc cryotrap"/></figure>



<p>The figure above shows the importance of the low GC cryo-trap temperature as well as the importance of a fast heating cold trap. Sample is Vinylchloride injected by PAL system with headspace tool.</p>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<p><strong>2406-3007 CryoFocus-4/LN2&nbsp;</strong>Direct LN2 Cooling Cryogenic GC Trap System without electronic flow control channel, including Evolution Workstation control software. Requires interface cable for GC and pressurized LN2 vessel (not included).<br><br><strong>2406-3008 CryoFocus-4/CO2&nbsp;</strong>Direct CO2 Cooling Cryogenic GC Trap System without electronic flow control channel, including Evolution Workstation control software. Requires interface cable for GC and liquid CO2 bottle (not included).</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.barascientific.com/general/gl-sciences-cryofocus/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>GL SCIENCES &#8211; VPS2800</title>
		<link>https://www.barascientific.com/general/gl-sciences-automated-fraction-collector-for-gas-chromatography-vps2800/</link>
					<comments>https://www.barascientific.com/general/gl-sciences-automated-fraction-collector-for-gas-chromatography-vps2800/#respond</comments>
		
		<dc:creator><![CDATA[BSC]]></dc:creator>
		<pubDate>Wed, 10 Apr 2024 11:06:20 +0000</pubDate>
				<category><![CDATA[Gas Chromatography]]></category>
		<category><![CDATA[GL Sciences]]></category>
		<guid isPermaLink="false">https://www.barascientific.com/general/?p=1665</guid>

					<description><![CDATA[Automated Fraction Collector for Gas Chromatography  A Preparative Gas Chromatograph system can collect the target compounds which were separated by Gas Chromatography. The VPS2800 GC fraction collector is designed to work with capillary columns and gives high recovery and pure fractionation. It is possible to collect just a part of a peak, one peak or [&#8230;]]]></description>
										<content:encoded><![CDATA[
<h2 class="wp-block-heading">Automated Fraction Collector for Gas Chromatography </h2>



<div class="wp-block-media-text is-stacked-on-mobile is-vertically-aligned-top" style="grid-template-columns:35% auto"><figure class="wp-block-media-text__media"><img loading="lazy" decoding="async" width="511" height="337" src="https://www.barascientific.com/general/wp-content/uploads/2024/04/VPS2800-image2.jpg" alt="" class="wp-image-1682 size-full" srcset="https://www.barascientific.com/general/wp-content/uploads/2024/04/VPS2800-image2.jpg 511w, https://www.barascientific.com/general/wp-content/uploads/2024/04/VPS2800-image2-300x198.jpg 300w, https://www.barascientific.com/general/wp-content/uploads/2024/04/VPS2800-image2-150x99.jpg 150w" sizes="auto, (max-width: 511px) 100vw, 511px" /></figure><div class="wp-block-media-text__content">
<p>A Preparative Gas Chromatograph system can collect the target compounds which were separated by Gas Chromatography. The VPS2800 GC fraction collector is designed to work with capillary columns and gives high recovery and pure fractionation. It is possible to collect just a part of a peak, one peak or a group of peaks with the GC fraction collector.<br>The preparative gc collection tube is available in two versions, a glass and a metal version. The minimum trapping temperature of -60°C is achieved with a Stirling cooling technique that is standard available in the VPS2800 GC fraction collector. With the easy to operate&nbsp;software, you just select a peak in the chromatogram or set a time window in order to collect a peak.<br><br>After collection, the components of interest can be transferred to other analysis techniques like NMR or UV/VIS or be used for reanalysis on GCMS.</p>
</div></div>



<p><br><strong>Strong points</strong></p>



<ul class="wp-block-list">
<li>Automated collection of compounds</li>



<li>Six collection traps and one waste</li>



<li>No valves and no cold spots for best possible recovery</li>



<li>No carry over by&nbsp;unique flow path</li>



<li>Deactivated sample flow path</li>



<li>Flow path can be heated till 380°C</li>



<li>Software&nbsp;control for easy set-up</li>



<li>Cooling without LN2</li>
</ul>



<h2 class="wp-block-heading"></h2>



<h2 class="wp-block-heading"></h2>
]]></content:encoded>
					
					<wfw:commentRss>https://www.barascientific.com/general/gl-sciences-automated-fraction-collector-for-gas-chromatography-vps2800/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>GL SCIENCES &#8211; HandyTD</title>
		<link>https://www.barascientific.com/general/gl-sciences-handytd-manual-thermal-desorption-for-gas-chromatographygl-sciences/</link>
					<comments>https://www.barascientific.com/general/gl-sciences-handytd-manual-thermal-desorption-for-gas-chromatographygl-sciences/#respond</comments>
		
		<dc:creator><![CDATA[BSC]]></dc:creator>
		<pubDate>Wed, 10 Apr 2024 11:05:47 +0000</pubDate>
				<category><![CDATA[Gas Chromatography]]></category>
		<category><![CDATA[GL Sciences]]></category>
		<guid isPermaLink="false">https://www.barascientific.com/general/?p=1668</guid>

					<description><![CDATA[Manual thermal desorption for Gas Chromatography HandyTD is an easy thermal desorption device for manual thermal desorption. The instrument has its own gas control, it needs only the main supply from the carrier gas line. HandyTD has a needle that is inserted into the inlet of the host GC and a gas frow from the [&#8230;]]]></description>
										<content:encoded><![CDATA[
<h2 class="wp-block-heading">Manual thermal desorption for Gas Chromatography</h2>



<div class="wp-block-media-text is-stacked-on-mobile" style="grid-template-columns:38% auto"><figure class="wp-block-media-text__media"><img loading="lazy" decoding="async" width="511" height="337" src="https://www.barascientific.com/general/wp-content/uploads/2024/04/HandyTD-image-2.jpg" alt="" class="wp-image-1678 size-full" srcset="https://www.barascientific.com/general/wp-content/uploads/2024/04/HandyTD-image-2.jpg 511w, https://www.barascientific.com/general/wp-content/uploads/2024/04/HandyTD-image-2-300x198.jpg 300w, https://www.barascientific.com/general/wp-content/uploads/2024/04/HandyTD-image-2-150x99.jpg 150w" sizes="auto, (max-width: 511px) 100vw, 511px" /></figure><div class="wp-block-media-text__content">
<p><strong>HandyTD</strong> is an easy thermal desorption device for manual thermal desorption. The instrument has its own gas control, it needs only the main supply from the carrier gas line. HandyTD has a needle that is inserted into the inlet of the host GC and a gas frow from the HandyTD will push the sample to the GC inlet. The colour display will guide the user to the operating steps. The size of the tubes used in the HandyTD are ¼ x 3½ inch, this is the size of the standard available thermal desorption tubes. The HandyTD can only be used with glass tubes.</p>
</div></div>



<p><strong>Strong points</strong></p>



<ul class="wp-block-list">
<li>Space-saving design</li>



<li>In-house patented technology achieves a fast heating rate</li>



<li>Compatible with any GC instrument</li>



<li>Easy touch panel operation without PC</li>



<li>Wizard function to navigate trough the operating procedure</li>



<li>Sample is direct injected into the GC</li>



<li>Equipped with electronic flow control (EPFC)</li>



<li>Tube / liner size is industry standard TD tube: 1/4 inch version (OD= ¼ x 3½ inch = 6.35 x 88.9 mm)</li>
</ul>



<p><strong>Publications with HandyTD:</strong></p>



<p>Elucidation of Biochemical Pathways Underlying VOCs Production in A549 Cells<br>Sampling, identification and sensory evaluation of odors of a newborn baby’s head and amniotic fluid</p>



<p><strong>Partnumbers:</strong><br>2702-30001 Manual Thermal Desorber, HandyTD<br>1050-78006 HandyTD startup kit<br>2709-80063 HandyTD Injection Supporter Fixation Kit for Agilent GC<br>2709-80064 HandyTD Injection Supporter Fixation Kit for GC-2010/2025/2030<br>2709-80065 HandyTD Injection Supporter for GC2014<br>2702-30002 HandyTD Injection Supporter for Trace 1300/1310<br>2702-30003 HandyTD GC Remote Cable for Shimadzu GC-2030<br>2702-30004 HandyTD GC Remote Cable for Agilent GC<br>2702-30005 HandyTD GC Remote Cable for Trace 1300/1310</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.barascientific.com/general/gl-sciences-handytd-manual-thermal-desorption-for-gas-chromatographygl-sciences/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>GL SCIENCES &#8211; Accessories for GC and GC-MS</title>
		<link>https://www.barascientific.com/general/gl-sciences-accessories-for-gc-and-gc-ms/</link>
					<comments>https://www.barascientific.com/general/gl-sciences-accessories-for-gc-and-gc-ms/#respond</comments>
		
		<dc:creator><![CDATA[BSC]]></dc:creator>
		<pubDate>Wed, 10 Apr 2024 10:54:06 +0000</pubDate>
				<category><![CDATA[Gas Chromatography]]></category>
		<category><![CDATA[GL Sciences]]></category>
		<guid isPermaLink="false">https://www.barascientific.com/general/?p=1725</guid>

					<description><![CDATA[Gas Filters / Pre-Conditioned HC Filter Pre-Conditioned HC Filter is an aged, activated carbon filter that is made without using the fluororesin sealing coating for joints. When concentrating the extract during the PFAS pre-treatment, place this PTFE-free activated carbon filter in the Nitrogen line. This will result in the reduction of contaminants derived from the [&#8230;]]]></description>
										<content:encoded><![CDATA[
<h3 class="wp-block-heading">Gas Filters / Pre-Conditioned HC Filter</h3>


<div class="wp-block-image">
<figure class="alignright"><img decoding="async" src="https://www.glsciences.eu/pfas/PreConditionedHCFilterforpfas.jpg" alt="gas filter for pfas"/></figure></div>


<p>Pre-Conditioned HC Filter is an aged, activated carbon filter that is made without using the fluororesin sealing coating for joints. When concentrating the extract during the PFAS pre-treatment, place this PTFE-free activated carbon filter in the Nitrogen line. This will result in the reduction of contaminants derived from the piping.</p>



<p>P/No: 3001-17005 Pre-Conditioned HC Filter, PTFE tape free. for 1/8in. Connection<br>P/No: 3001-17006 Pre-Conditioned HC Filter, PTFE tape free. for 1/4in. Connection</p>



<hr class="wp-block-separator has-alpha-channel-opacity"/>


<div class="wp-block-image">
<figure class="alignright"><img decoding="async" src="https://www.glsciences.eu/pictures/6010-81230.jpg" alt="Plier-Type Tubing Cutter"/></figure></div>


<h3 class="wp-block-heading">Plier-Type Tubing Cutter</h3>



<p>This tubing cutter makes clean cuts on 1/16 inch O.D. stainless steel tubing and ideal for cutting tubing in tight places.</p>



<p>Part Number: 6010-81230 &nbsp;&nbsp;1/16 inch Tubing Cutter</p>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<h3 class="wp-block-heading">Rotary Tubing Cutter for 1/16 inch tubing</h3>


<div class="wp-block-image">
<figure class="alignright"><img decoding="async" src="https://www.glsciences.eu/pictures/3001-31701.jpg" alt="tubing cutter for 1/16"/></figure></div>


<figure class="wp-block-image"><img decoding="async" src="https://www.glsciences.eu/pictures/3001-31712.jpg" alt="cutter replacement blades"/></figure>



<p>Part Number: 3001-31701 &nbsp;&nbsp;Rotary Tubing Cutter for 1/16 inch tubing<br>Part Number: 3001-31712 &nbsp;&nbsp;cutter replacement blade (3 pieces)</p>



<hr class="wp-block-separator has-alpha-channel-opacity"/>


<div class="wp-block-image">
<figure class="alignright"><img decoding="async" src="https://www.glsciences.eu/pictures/3001-31451.jpg" alt="1/8 tubing cutter"/></figure></div>


<h2 class="wp-block-heading">Tube cutter</h2>



<p>The mini tube cutter is a cutter that can easily cut tubes from 4 mm to 5/8 inch (15.875 mm).</p>



<p>Part Number: 3001-31451 &nbsp;&nbsp;Mini tube cutter<br>Part Number: 3001-31312 &nbsp;&nbsp;Mini tube cutter replacement blade</p>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<h2 class="wp-block-heading">Ferrule removal tool</h2>



<figure class="wp-block-image"><img decoding="async" src="https://www.glsciences.eu/pictures/ferrule_removal_tool.gif" alt="ferrule removal tool"/></figure>



<p>Remove the ferrule out of the nut in an easy way.<br>Can be used with most common nuts and ferrules.<br>The O.D. of the pushing pin is 1 mm. Cannot be used with the OPTIC metal ferrules (only for graphite).</p>



<p>Part Number: 3001-12745 &nbsp;&nbsp;ferrule removal tool</p>



<hr class="wp-block-separator has-alpha-channel-opacity"/>


<div class="wp-block-image">
<figure class="alignright"><a href="https://www.glsciences.eu/sgt/column-cut.jpg" rel="noopener"><img decoding="async" src="https://www.glsciences.eu/sgt/column-cut-2.jpg" alt="column cutter"/></a></figure></div>


<h2 class="wp-block-heading">Shortix® Capillary GC Column Cutter</h2>



<p>&#8211; Clean, square cuts with a diamond blade.<br>&#8211; Built-in magnifier to verify square cut.<br>&#8211; Use with 0.25mm ID to 0.53mm ID tubing (0.78mm OD maximum).</p>



<p>Part number: SGT-S0010 Shortix Column Cutter &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p>



<hr class="wp-block-separator has-alpha-channel-opacity"/>


<div class="wp-block-image">
<figure class="alignright"><img decoding="async" src="https://www.glsciences.eu/pictures/ceramic-cutter.jpg" alt="ceramic gc column cutter"/></figure></div>


<h2 class="wp-block-heading">Ceramic Capillary GC Column Cutter</h2>



<p>Part number: 1010-41100 Ceramic Tube Cutter (set of 4)</p>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<h2 class="wp-block-heading">Ferrule sets</h2>


<div class="wp-block-image">
<figure class="alignleft"><a href="https://www.glsciences.eu/pictures/3001-12740.jpg" rel="noopener"><img decoding="async" src="https://www.glsciences.eu/pictures/3001-12740-s.png" alt="ferrule tool"/></a></figure></div>


<p>Part number: 3001-12740 &nbsp;&nbsp;Ferrule Removal kit<br>Kit has two tools; one for removing 0.4mm adaptor ferrules and one for 0.8mm</p>


<div class="wp-block-image">
<figure class="alignleft"><a href="https://www.glsciences.eu/pictures/drill-set.png" rel="noopener"><img decoding="async" src="https://www.glsciences.eu/pictures/drill-set-s.png" alt="ferrule drill set"/></a></figure></div>


<p>Part number: 3001-24625 pin vice drill set</p>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<h2 class="wp-block-heading">Merlin microseal</h2>


<div class="wp-block-image">
<figure class="alignright"><img decoding="async" src="https://www.glsciences.eu/pictures/merlin-microseal.png" alt="Merlin Microseal"/></figure></div>


<p>The Merlin Microseal is a long-life replacement for the standard septum used in Gas Chromatography. High pressure capability and resistance to wear make it the most unique septum on the market today. The Microseal fits standard in the OPTIC-4 inlet and is also available for many different GC types.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.barascientific.com/general/gl-sciences-accessories-for-gc-and-gc-ms/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
