Page 16 - inspeXioSMX-100CT
P. 16
Standard Specifications inspeXio SMX-100CT
Model inspeXio SMX-100CT inspeXio SMX-225CT inspeXio SMX-90CT
P/N S362-79800-92 S362-69100-22 S362-65000-52
X-Ray Generator Sealed tube type, Rated power: 20 W Non-enclosure tube type, Rated power: 135 W Sealed tube type, Rated power: 10 W
Max. tube voltage: 100 kV Max. tube voltage: 225 kV Max. tube voltage: 90 kV
Max. tube current: 200 μA Max. tube current: 100 μA Max. tube current: 250 μA
X-Ray Detector Image intensifier Image intensifier Digital flat panel detector
Max. Stroke of CT Stage SOD axis (*1) : 540 mm SOD axis (*1) : 670 mm SOD axis (*1) : 200 mm
SID axis (*2) : Can be switched between 4 levels SID axis (*2) : Can be switched between 4 levels Z axis: 50 mm
200, 300, 500, and 700 mm 400, 600, 800, and 1,000 mm
Z axis: 150 mm Z axis: 300 mm
Max. Sample Size 180 mm dia. × H250 mm, 4 kg max. 300 mm dia. × H300 mm, 9 kg max. 160 mm dia. × H100 mm, 4 kg max.
Max. CT Scan Area (FOV) 90 mm dia. (for 2DCT: 115 mm dia.) 200 mm dia. 50 mm dia.
Scanning Methods Normal scan, half scan, offset scan, Normal scan, half scan, offset scan, Offset scan, CBCT (*5)
FS scan (*3) ,2DCT (*4) /CBCT (*5) FS scan (*3) , 2DCT (*4) /CBCT (*5)
CT Data Acquisition Time Any value from 10 sec to 30 min Any value from 10 sec to 30 min Any value from 40 sec to 30 min
CT Image Sizes 512 × 512, 1024 × 1024, 512 × 512, 1024 × 1024, 512 × 512, 1024 × 1024
2048 × 2048, 4096 × 4096 2048 × 2048, 4096 × 4096
Dimensions and Weight of Shield Box W1,613 × D841 × H1,450 mm, approx. 1,200 kg W2,170 × D1,350 × H1,857 mm, approx. 3,100 kg W830 × D601 × H587 mm, approx. 250 kg
Dimensions and Weight of Dedicated Desk W1,200 × D700 × H1,270 mm, approx. 50 kg W1,200 × D700 × H1,270 mm, approx. 50 kg W1,500 × D750 × H740 mm, approx. 60 kg
Power Requirements Main unit: 100 V AC ±10 %, 50/60 Hz, 1 kVA Main unit: 200 V AC ±10 %, 50/60 Hz, 3 kVA 100 V AC ±10 %, 50/60 Hz, 1 kVA
Control computer: 100 V AC ±10 %, 50/60 Hz, 1 kVA Control computer: 100 V AC ±10 %, 50/60 Hz, 1 kVA Class D grounding (max. ground resistance of 100 Ω)
Class D grounding (max. ground resistance of 100 Ω) Class D grounding (max. ground resistance of 100 Ω)
X-Ray Leakage Rate 1 μSv/h max. 1 μSv/h max. 1 μSv/h max.
(*1) SOD axis: Source to Object Distance, the distance from the X-ray focal point to the sample.
(*2) SID axis: Source to Image Distance, the distance from the X-ray focal point to the X-ray detector.
(*3) FS scan: Fan-Shaped Image Distance, a scanning method that obtains CT images at rotation angles of 60, 90, and 120 degrees.
(*4) 2DCT: 2-Dimensional Computed Tomography, a scanning method that obtains one or three CT images with a single scan.
(*5) CBCT: Cone Beam Computed Tomography, a scanning method that obtains hundreds of CT images with a single scan.
Transformer Box
(350)
(250)
(2100)
inspeXio SMX-100CT Main Unit
(1200)
(700)
(3000)
(1450)
(255) (700)
(700) (1613) (1200) (841)
Company names, product/service names and logos used in this publication are trademarks and trade names of Shimadzu Corporation or its
affiliates, whether or not they are used with trademark symbol “TM” or “®”.
Third-party trademarks and trade names may be used in this publication to refer to either the entities or their products/services. Shimadzu
disclaims any proprietary interest in trademarks and trade names other than its own.
For Research Use Only. Not for use in diagnostic procedures.
The contents of this publication are provided to you “as is” without warranty of any kind, and are subject to change without notice. Shimadzu
does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication.
www.shimadzu.com/an/ © Shimadzu Corporation, 2012
Printed in Japan 3655-08206-30A-IK